Article Abstract

Background: Robot-assisted microsurgery (RAMS) is gradually becoming the preferred method for some delicate surgical procedures. However, the lack of haptic feedback reduces the safety of the surgery. Surgeons are unable to feel the grasping force between surgical instruments and the patient's tissues, which can easily lead to grasping failure or tissue damage.

Methods: This paper proposes a tendon-driven grasping force feedback mechanism, consisting of a follower hand and a leader hand, to address the lack of grasping force feedback in flexible surgical robots. Considering the friction in the tendon transmission process, a grasping force estimation model is established for the follower hand. The admittance control model is designed for force/position control of the leader hand.

Results: Through experimental validation, it has been confirmed that the grasping force sensing range of the follower hand is 0.5-5 N, with a sensing accuracy of 0.3 N. The leader hand is capable of providing feedback forces in the range of 0-5 N, with a static force accuracy of 0.1 N.

Conclusions: The designed mechanism and control strategy can provide the grasping force feedback function. Future work will focus on improving force feedback performance.

Trial Registration: This research has no clinical trials.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcs.2667DOI Listing

Publication Analysis

Top Keywords

grasping force
28
force feedback
20
follower hand
12
force
9
feedback mechanism
8
flexible surgical
8
surgical robots
8
leader hand
8
feedback
7
grasping
7

Similar Publications

This study aimed to evaluate the resistance of anastomoses to mechanical traction in an ex vivo biomechanical experiment, to determine the most resistant manual suture for restoring digestive tract continuity after various types of gastric resection for cancer. Materials and methods: The tensile strength of different types of anastomoses was compared ex vivo using porcine esophagus, stomach, and small intestine. The test setup included a tensile testing device, which applied a controlled force on the anastomoses until they broke, which was recorded for each type of anastomosis and was expressed in N.

View Article and Find Full Text PDF

The aqueous extract of Moringa oleifera leaves has been previously characterized for its polyphenolic composition, yet the behavior of its colloidal aggregates under dilution remains largely unexplored. In this study, we investigate the structural and chemical properties of these aggregates at room temperature, focusing on their stability and surface exposure upon dilution. Although the aggregates break up as dilution increases, they never fully dissolve within the conditions explored.

View Article and Find Full Text PDF

Limb loss affects millions globally, impairing physical function and reducing quality of life. Most traditional surface electromyographic (sEMG) and semi-autonomous methods require users to generate myoelectric signals for each control, imposing physically and mentally taxing demands. This study aims to develop a fully autonomous control system that enables a prosthetic hand to automatically grasp and release objects of various shapes using only a camera attached to the wrist.

View Article and Find Full Text PDF

Functional electrical stimulation (FES) is an effective technique for restoring or enhancing hand motor function in patients with neurological impairments, such as those recovering from stroke or spinal cord injuries. Although many studies have used phenomenological models to investigate the control of FES, few studies have simultaneously employed both methods to study finger output force. This study aims to accurately predict finger output force using the Hill model and a multi-joint finger model under different current conditions.

View Article and Find Full Text PDF

Auxiliary buttons are often required in clear aligner therapy for elastic traction. We introduce an adhesiveless flame-fusion technique for affixing auxiliary metal buttons to clear aligners, aiming to eliminate the extra chair time, occasional debonding, and translucent haze associated with resin adhesives. Round‑base stainless‑steel buttons are grasped with locking forceps, heated in an alcohol flame (~600-650 °C for 10-15 s), and immediately pressed with moderate manual pressure (~5 N) for 5-10 s onto 0.

View Article and Find Full Text PDF