Article Abstract

Background: Accurate measurements from cardiovascular magnetic resonance (CMR) images require precise positioning of scan planes and elimination of motion artifacts from arrhythmia or breathing. Unidentified or incorrectly managed artifacts degrade image quality, invalidate clinical measurements, and decrease diagnostic confidence. Currently, radiographers must manually inspect each acquired image to confirm diagnostic quality and decide whether reacquisition or a change in sequences is warranted. We aimed to develop artificial intelligence (AI) to provide continuous quality scores across different quality domains, and from these, determine whether cines are clinically adequate, require replanning, or warrant a change in protocol.

Methods: A three-dimensional convolutional neural network was trained to predict cine quality graded on a continuous scale by a level 3 CMR expert, focusing separately on planning and motion artifacts. It incorporated four distinct output heads for the assessment of image quality in terms of (a, b, c) 2-, 3- and 4-chamber misplanning, and (d) long- and short-axis arrhythmia/breathing artifact. Backpropagation was selectively performed across these heads based on the labels present for each cine. Each image in the testing set was reported by four level 3 CMR experts, providing a consensus on clinical adequacy. The AI's assessment of image quality and ability to identify images requiring replanning or sequence changes were evaluated with Spearman's rho and the area under receiver operating characteristic curve (AUROC), respectively.

Results: A total of 1940 cines across 1387 studies were included. On the test set of 383 cines, AI-judged image quality correlated strongly with expert judgment, with Spearman's rho of 0.84, 0.84, 0.81, and 0.81 for 2-, 3- and 4-chamber planning quality and the extent of arrhythmia or breathing artifacts, respectively. The AI also showed high efficacy in flagging clinically inadequate cines (AUROC 0.88, 0.93, and 0.93 for identifying misplanning of 2-, 3- and 4-chamber cines, and 0.90 for identifying movement artifacts).

Conclusion: AI can assess distinct domains of CMR cine quality and provide continuous quality scores that correlate closely with a consensus of experts. These ratings could be used to identify cases where reacquisition is warranted and guide corrective actions to optimize image quality, including replanning, prospective gating, or real-time imaging.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11416635PMC
http://dx.doi.org/10.1016/j.jocmr.2024.101067DOI Listing

Publication Analysis

Top Keywords

image quality
20
motion artifacts
12
quality
12
magnetic resonance
8
artificial intelligence
8
planning motion
8
arrhythmia breathing
8
provide continuous
8
continuous quality
8
quality scores
8

Similar Publications

The aim of the study was to evaluate the toxic metals (TMs) pollution, bioaccumulation and its potential health risk via consumption of different vegetables irrigated by different water sources released from industrial estates of Khyber Pakhtunkhwa. Water (fresh and waste), soil and vegetables samples were collected in triplicates and acid digested. Digestion of samples were followed by evaporation and filtration and then assessed for TMs via atomic absorption spectrophotometer.

View Article and Find Full Text PDF

Myocarditis is an inflammation of heart tissue. Cardiovascular magnetic resonance imaging (CMR) has emerged as an important non-invasive imaging tool for diagnosing myocarditis, however, interpretation remains a challenge for novice physicians. Advancements in machine learning (ML) models have further improved diagnostic accuracy, demonstrating good performance.

View Article and Find Full Text PDF

[The TAVI heart team].

Herz

September 2025

Department of Cardiology, Heart Center Leipzig, University of Leipzig, Strümpellstraße 39, 04289, Leipzig, Deutschland.

Since the earliest studies on transcatheter aortic valve implantation (TAVI), the heart team concept has been an integral component of treatment planning for patients with aortic valve stenosis (AS). The primary objective is to ensure patient-specific, guideline-based treatment through the structured involvement of all relevant medical disciplines. The TAVI heart team is strongly recommended with a class I indication in both European and US clinical guidelines.

View Article and Find Full Text PDF

Diagnostic tips for multi-phase post-mortem computed tomography angiography interpretation in upper gastro-intestinal bleeding.

Int J Legal Med

September 2025

University Center of Legal Medicine Lausanne-Geneva, University of Geneva, Geneva University Hospitals, Rue Michel-Servet 1, 1211, Geneva 4, Switzerland.

In the past 10 years, the Multi-phase Post-mortem Computed Tomography Angiography (MPMCTA) has considerably improved the quality and precision of postmortem diagnoses, particularly in cases with vascular implication. MPMCTA is known to have higher sensitivity for detecting the source of a hemorrhage than autopsy. Death by upper gastro-intestinal (GI) bleeding is not so uncommon in forensic practice.

View Article and Find Full Text PDF

Background: Stroke, frequently associated with carotid artery disease, is evaluated using carotid computed tomography angiography (CTA). Dual-energy CTA (DE-CTA) enhances imaging quality but presents challenges in maintaining high image clarity with low-dose scans.

Objectives: To compare the image quality of 50 keV virtual monoenergetic images (VMI) generated using Deep Learning Image Reconstruction (DLIR) and Adaptive Statistical Iterative Reconstruction-V (ASIR-V) algorithms under a triple-low scanning protocol in carotid CTA.

View Article and Find Full Text PDF