Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Early detection of cognitive impairment is among the top research priorities aimed at reducing the global burden of dementia. Currently used screening tools have high sensitivity but lack specificity at their original cut-off, while decreasing the cut-off was repeatedly shown to improve specificity, but at the cost of lower sensitivity. In 2012, a new screening tool was introduced that aims to overcome these limitations - the Quick mild cognitive impairment screen (Qmci). The original English Qmci has been rigorously validated and demonstrated high diagnostic accuracy with both good sensitivity and specificity. We aimed to determine the optimal cut-off value for the German Qmci, and evaluate its diagnostic accuracy, reliability (internal consistency) and construct validity.

Methods: We retrospectively analyzed data from healthy older adults (HOA; n = 43) and individuals who have a clinical diagnosis of 'mild neurocognitive disorder' (mNCD; n = 37) with a biomarker supported characterization of the etiology of mNCD of three studies of the 'Brain-IT' project. Using Youden's Index, we calculated the optimal cut-off score to distinguish between HOA and mNCD. Receiver operating characteristic (ROC) curve analysis was performed to evaluate diagnostic accuracy based on the area under the curve (AUC). Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Reliability (internal consistency) was analyzed by calculating Cronbach's α. Construct validity was assessed by analyzing convergent validity between Qmci-G subdomain scores and reference assessments measuring the same neurocognitive domain.

Results: The optimal cut-off score for the Qmci-G was ≤ 67 (AUC = 0.96). This provided a sensitivity of 91.9% and a specificity of 90.7%. The PPV and NPV were 89.5% and 92.9%, respectively. Cronbach's α of the Qmci-G was 0.71 (CI [0.65 to 0.78]). The Qmci-G demonstrated good construct validity for subtests measuring learning and memory. Subtests that measure executive functioning and/or visuo-spatial skills showed mixed findings and/or did not correlate as strongly as expected with reference assessments.

Conclusion: Our findings corroborate the existing evidence of the Qmci's good diagnostic accuracy, reliability, and construct validity. Additionally, the Qmci shows potential in resolving the limitations of commonly used screening tools, such as the Montreal Cognitive Assessment. To verify these findings for the Qmci-G, testing in clinical environments and/or primary health care and direct comparisons with standard screening tools utilized in these settings are warranted.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11256646PMC
http://dx.doi.org/10.1186/s12877-024-05219-3DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
20
construct validity
16
accuracy reliability
12
cognitive impairment
12
screening tools
12
optimal cut-off
12
reliability construct
8
quick mild
8
mild cognitive
8
impairment screen
8

Similar Publications

Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.

View Article and Find Full Text PDF

Aim: The purpose of this study was to assess the accuracy of a customized deep learning model based on CNN and U-Net for detecting and segmenting the second mesiobuccal canal (MB2) of maxillary first molar teeth on cone beam computed tomography (CBCT) scans.

Methodology: CBCT scans of 37 patients were imported into 3D slicer software to crop and segment the canals of the mesiobuccal (MB) root of the maxillary first molar. The annotated data were divided into two groups: 80% for training and validation and 20% for testing.

View Article and Find Full Text PDF

Background: Current scoring systems for hypertriglyceridaemia-induced acute pancreatitis (HTG-AP) severity are few and lack reliability. The present work focused on screening predicting factors for HTG-SAP, then constructing and validating the visualization model of HTG-AP severity by combining relevant metabolic indexes.

Methods: Between January 2020 and December 2024, retrospective clinical information for HTG-AP inpatients from Weifang People's Hospital was examined.

View Article and Find Full Text PDF

Obsessive-compulsive disorder (OCD) is a chronic and disabling condition affecting approximately 3.5% of the global population, with diagnosis on average delayed by 7.1 years or often confounded with other psychiatric disorders.

View Article and Find Full Text PDF

Background: Thyroid nodules (TNs) are frequent and often benign. Accurately differentiating between benign and malignant nodules is crucial for proper management. This research aims to use ultrasonography to examine TNs and identify possible risk factors in order to improve patient outcomes and diagnostic accuracy.

View Article and Find Full Text PDF