A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Graphene oxide-loaded rapamycin coating on airway stents inhibits stent-related granulation tissue hyperplasia. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: Our objective was to explore the safety and efficacy of a graphene oxide-loaded rapamycin-coated self-expandable metallic airway stent (GO@RAPA-SEMS) in a rabbit model.

Methods: The dip coating method was used to develop a GO@RAPA-SEMS and a poly(lactic-co-glycolic)-acid loaded rapamycin-coated self-expandable metallic airway stent (PLGA@RAPA-SEMS). The surface structure was evaluated using a scanning electronic microscope. The in vitro drug-release profiles of the 2 stents were explored and compared. In the animal study, a total of 45 rabbits were randomly divided into 3 groups and underwent 3 kinds of stent placements. Computed tomography was performed to evaluate the degree of stenosis at 1, 2 and 3 months after the stent operation. Five rabbits in each group were sacrificed after the computed tomography scan. The stented trachea and blood were collected for further pathological analysis and laboratory testing.

Results: The in vitro drug-release study revealed that GO@RAPA-SEMS exhibited a sudden release on the first day and maintained a certain release rate on the 14th day. The PLGA@RAPA-SEMS exhibited a longer sustained release time. All 45 rabbits underwent successful stent placement. Pathological results indicated that the granulation tissue thickness in the GO@RAPA-SEMS group was less than that in the PLGA@RAPA-SEMS group. The TUNEL and hypoxia-inducible factor-1α staining results support the fact that the granulation inhibition effect in the GO@RAPA-SEMS group was greater than that in the PLGA@RAPA-SEMS group.

Conclusions: GO@RAPA-SEMS effectively inhibited stent-related granulation tissue hyperplasia.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ejcts/ezae270DOI Listing

Publication Analysis

Top Keywords

granulation tissue
12
graphene oxide-loaded
8
stent-related granulation
8
tissue hyperplasia
8
rapamycin-coated self-expandable
8
self-expandable metallic
8
metallic airway
8
airway stent
8
vitro drug-release
8
computed tomography
8

Similar Publications