Article Abstract

Background: Ventricular tachycardia (VT), which can lead to sudden cardiac death, occurs frequently in patients after myocardial infarction. Radiofrequency catheter ablation (RFA) is a modestly effective treatment of VT, but it has limitations and risks. Cardiac magnetic resonance (CMR)-based heart digital twins have emerged as a useful tool for identifying VT circuits for RFA treatment planning. However, the CMR resolution used to reconstruct these digital twins may impact VT circuit predictions, leading to incorrect RFA treatment planning.

Objectives: This study sought to predict RFA targets in the arrhythmogenic substrate using heart digital twins reconstructed from both clinical and high-resolution 2-dimensional CMR datasets and compare the predictions.

Methods: High-resolution (1.35 × 1.35 × 3 mm), or oversampled resolution (Ov-Res), short-axis late gadolinium-enhanced CMR was acquired by combining 2 subsequent clinical resolution (Clin-Res) (1.35 × 1.35 × 6 mm) short-axis late gadolinium-enhanced CMR scans from 6 post-myocardial infarction patients undergoing VT ablation and used to reconstruct a total of 3 digital twins (1 Ov-Res, 2 Clin-Res) for each patient. Rapid pacing was used to assess VT circuits and identify the optimal ablation targets in each digital twin. VT circuits predicted by the digital twins were compared with intraprocedural electroanatomic mapping data and used to identify emergent VT.

Results: The Ov-Res digital twins reduced partial volume effects and better predicted unique VT circuits compared with the Clin-Res digital twins (66.6% vs 54.5%; P < 0.01). Only the Ov-Res digital twin successfully identified emergent VT after a failed initial ablation.

Conclusions: Digital twin infarct geometry and VT circuit predictions depend on the magnetic resonance resolution. Ov-Res digital twins better predict VT circuits and emergent VT, which may improve RFA outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacep.2024.04.032DOI Listing

Publication Analysis

Top Keywords

digital twins
36
digital
12
heart digital
12
digital twin
12
ov-res digital
12
twins
9
ventricular tachycardia
8
magnetic resonance
8
rfa treatment
8
circuit predictions
8

Similar Publications

Computational modeling and simulation in oncology.

Clin Transl Med

September 2025

Department of Computer Science and Biomedical Engineering, Institute of Health Care Engineering with European Testing Center of Medical Devices, Graz University of Technology, Graz, Austria.

Computational modeling and simulation are playing an increasingly important role in oncology, bridging biological research, data science and clinical practice to better understand cancer complexity and inform therapeutic development. This special issue presents recent advances in multiscale modeling, artificial intelligence-driven systems, digital twins, and in silico trials, illustrating the evolving potential of computational tools to support innovation from bench to bedside. Together, these contributions outline a future in which precision medicine, adaptive therapies and personalized diagnostics are guided by integrative and predictive modeling approaches.

View Article and Find Full Text PDF

Remote training of a reservoir computer via digital twins.

Chaos

September 2025

Department of Information Physics and Computing, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.

The increasing energy consumption required for information processing has become a significant challenge, leading to growing interest in optical and optoelectronic reservoir computing as a more efficient alternative. Trained reservoir computers are especially suited for low-energy applications near the edge. However, the computational cost of training the reservoir output weights, particularly due to matrix operations, adds potentially unwanted complexity to the architecture.

View Article and Find Full Text PDF

Background: Photon-counting computed tomography (CT) bears promise to substantially improve spectral and spatial resolution. One reason for the relatively slow evolution of photon-counting detectors in CT-the technology has been used in nuclear medicine and planar radiology for decades-is pulse pileup, that is, the random staggering of pulses, resulting in count loss and spectral distortion, which in turn cause image bias and reduced contrast-to-noise ratio (CNR). The deterministic effects of pileup can be mitigated with a pileup-correction algorithm, but the loss of CNR cannot be recovered, and must be minimized by hardware design.

View Article and Find Full Text PDF