Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: To compare the accuracy and operative time of implant placement using a dynamic computer assisted implant surgery (dCAIS) system based on a cone beam computer tomography (CBCT) image, with and without superimposing a standard tessellation language (STL) file of an intraoral scan of the patient.

Methods: Ten identical resin models simulating an upper maxilla with posterior edentulism were assigned to two groups. In the CBCT+STL group, a CBCT file and an intraoral STL file were superimposed and used for registration; in the CBCT group, registration was performed using CBCT images. Six implants were placed in each model using the Navident® dynamic navigation system. Anatomy registration was performed by tracing fiducial points on the CBCT or STL image, depending on the group. Preoperative and postoperative CBCT images were overlaid to assess implant placement accuracy.

Results: Sixty implants were analyzed (30 implants in each group). 3D platform deviation was significantly lower (mean difference (MD): 0.17 mm; 95 % confidence interval (CI): 0.01 to 0.23; P = 0.039) in the CBCT+STL group (mean: 0.71 mm; standard deviation (SD): 0.29) than in the CBCT group (mean: 0.88 mm; SD: 0.39). The remaining accuracy outcome variables (angular deviation MD: -0.01; platform lateral deviation MD: 0.08 mm; apex global MD: 0.01 mm; apex depth MD: 0.33 mm) and surgery time (MD: 3.383 min.) were similar in both groups (p > 0.05).

Conclusions: The introduction of an intraoral scan (STL) seems to reduce deviations slightly in dental implant placement with dCAIS systems. However, the clinical repercussion of this improvement is questionable.

Clinical Significance: Superimposing an intraoral scan on the CBCT image does not seem to increase the accuracy of dCAIS systems but can be useful when radiographic artifacts are present.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jdent.2024.105150DOI Listing

Publication Analysis

Top Keywords

intraoral scan
16
stl file
12
file intraoral
12
implant placement
12
cbct
9
dynamic navigation
8
navigation system
8
superimposing standard
8
standard tessellation
8
tessellation language
8

Similar Publications

Enhancing the accuracy of full-arch digital implant impressions via segmentation: An in vitro study.

J Prosthodont

September 2025

Department of Graphic Design and Engineering Projects, Faculty of Engineering Gipuzkoa, University of the Basque Country UPV/EHU, San Sebastian, Spain.

Purpose: The aim of this in vitro study was to assess whether the accuracy (trueness and precision) of full-arch implant digital impressions can be improved by replacing standard digital impressions (StDIs) with segmented digital impressions (SgDIs), obtained by superimposing short-span digital impressions using a geometric pattern.

Materials And Methods: The study was conducted using a commercial edentulous maxillary model with four implants-positioned at the sites of the canines and second molars-and four commercial intraoral scan bodies (ISBs) screwed to them. Ten StDIs and SgDIs of the model were obtained, and their accuracy was evaluated and compared in terms of trueness and precision, based on measurements of three distances and three angles between the ISBs.

View Article and Find Full Text PDF

Purpose: To present a novel digital workflow (the Columbus Digital Bridge Protocol) for immediately loaded full-arch rehabilitations, integrating digital technologies throughout diagnostic, surgical and prosthetic phases, with a focus on the application of intraoral photogrammetry scanning.

Materials And Methods: The workflow presented in this article, successfully implemented in 14 patients, includes standardised clinical steps: digital diagnostic planning through matching of facial scans and CBCT data, surgical placement of four implants following tooth extraction, immediate post-surgical intraoral photogrammetry scanning using a three-step procedure (i.e.

View Article and Find Full Text PDF

The aim of the study is to present a case of a dermoid cyst in the oral floor of an 80-year-old female patient and discuss its clinical presentation, diagnostic approach, and treatment. A retrospective case study was conducted at the Department of Maxillofacial Surgery, Aulss 2 Marca Trevigiana. The patient, with a medical history of hypertension, presented with a swelling in the oral floor.

View Article and Find Full Text PDF

Purpose: Designing restorations remains challenging because the process is time-consuming and requires operator skill and experience. This clinical study evaluated the fit accuracy of polymerized complete crowns fabricated using a web-based 3D generative artificial intelligence design (GAID) method compared to crowns fabricated using a conventional computer-aided design (CCAD) method.

Materials And Methods: Sixty-two patients requiring complete crowns in maxillary and mandibular premolars and molars were enrolled.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the effect of clinically practical auxiliary geometric devices (AGD) on measurement trueness and scan time in full-arch implant-supported prostheses, focusing on different intraoral scanners (IOS) and implant angulations.

Materials And Methods: Four implants were planned in an edentulous maxillary arch and divided into two groups based on posterior implant angulation: Model A (Parallel) and Model B (30°). Each model was evaluated under three auxiliary geometric devices (AGD) application types (std, agd1, agd2), and scanned using three different intraoral scanners (IOSs) [3Shape Trios 3 (T), Medit i700 (M), and Cerec Primescan (PS)], resulting in nine groups per model (n = 10).

View Article and Find Full Text PDF