The aim of this study was to evaluate the impact of autoclaving on the dimensional stability of surgical guides (SGs) for aesthetic crown lengthening (ACL) using different resins/printing methods. Fifty SGs for ACL were printed using five different resin/printer combinations (FL, SR, ND, KS and VC). All the SGs were scanned before (T0) and after (T1) sterilization.
View Article and Find Full Text PDFClin Exp Dent Res
August 2025
The rapid development of computer-assisted implant surgery (CAIS) and the respective research and clinical applications have necessitated a standardization of the terminology related not only to different devices, but also the different steps involved, surgical and presurgical procedures. The present glossary was introduced at the 1st International Team for Implantology Symposium on Computer-assisted Implant Surgery, based on the collective work of clinicians and researchers with deep understanding and experience in these technologies. The glossary was further refined and revised through the structured input of a large group of global experts within clinical application, research, and education of CAIS.
View Article and Find Full Text PDFObjective: To compare the accuracy of zygomatic implant placement using a dynamic computer-assisted implant surgery system (D-CAIS) versus the traditional freehand approach.
Methods: An experimental in vitro study was conducted using 10 stereolithographic models randomized to two groups: D-CAIS (test group) and freehand placement (control group). A single zygomatic implant was placed on each side of the models.
Objective: This study aimed to evaluate the efficacy and safety of a digitally guided dual technique during esthetic crown lengthening surgery. In addition, patient satisfaction and patient-reported outcomes were assessed.
Materials And Methods: A prospective case series study was conducted.
: Achieving ideal anchorage is crucial in orthodontics for controlled tooth movement. Miniscrews (MSs) have improved skeletal anchorage, but freehand placement poses risks like root damage and limited precision. Guided techniques, including radiographic guides and computer-assisted methods (static [sCAS] and dynamic [dCAS]), were developed to enhance accuracy and safety.
View Article and Find Full Text PDFReal-time surgical navigation systems (dynamic computer-aided surgery, d-CAIS) and static guided surgery (static computer-aided surgery, s-CAIS) have been shown to enhance the accuracy of zygomatic implant (ZI) placement. The objective of this systematic review was to evaluate and compare the accuracy and risk of complications associated with d-CAIS and s-CAIS in ZI placement. A systematic review of published studies involving more than 4 patients was conducted to assess and compare the accuracy of d-CAIS and s-CAIS in zygomatic implant placement.
View Article and Find Full Text PDFObjective: To evaluate the accuracy of immediate implant placement in fresh extraction sockets in the maxillary aesthetic zone using a dynamic computer-assisted implant surgery system (dCAIS), with the evaluation of possible deviations versus freehand placement.
Methods: A total of 18 implants were placed by an experienced surgeon in fresh extraction sockets of anterior teeth in 6 maxillary models. Nine implants were placed using the dCAIS system and 9 implants were placed using the conventional freehand technique.
Int J Periodontics Restorative Dent
September 2025
Several treatment-oriented classifications for the management of peri-implant marginal mucosal defects (PMMDs) have been published to date. While each classification provides valuable insights into key diagnostic and therapeutic aspects, there is a marked heterogeneity regarding the rec-ommended clinical guidelines to achieve success in specific scenarios. The purpose of this review was to critically analyze and organize the similarities and differences enclosed in the available classifications linked with treatment recommendations on the management of PMMDs at nonmolar single-implant sites with the purpose of providing an overview of recommended interdisciplinary treatment options to facilitate clinical decision-making processes.
View Article and Find Full Text PDFObjectives: To compare miniscrew versus bone tracing registration methods on dental implant placement accuracy and time efficiency in edentulous jaws using a dynamic computer-assisted implant surgery (d-CAIS) system.
Methods: Twelve fully edentulous maxillary models were allocated into two groups: miniscrew tracing (MST) group, where registration was performed by tracing four miniscrews; and bone tracing (BT) group, where registration was conducted by tracing maxillary bone fiducial landmarks. Six implants were placed on each model using the X-Guide® d-CAIS system.
J Dent
September 2024
Objectives: To compare the accuracy and operative time of implant placement using a dynamic computer assisted implant surgery (dCAIS) system based on a cone beam computer tomography (CBCT) image, with and without superimposing a standard tessellation language (STL) file of an intraoral scan of the patient.
Methods: Ten identical resin models simulating an upper maxilla with posterior edentulism were assigned to two groups. In the CBCT+STL group, a CBCT file and an intraoral STL file were superimposed and used for registration; in the CBCT group, registration was performed using CBCT images.
Objectives: This study aims to compare the histological outcomes of three distinct de-epithelialization methods used in (connective tissue grafts) CTG harvested from the palate.
Materials And Methods: An experimental study using nine cadaver head specimens was carried out to compare 3 different de-epithelialization techniques for CTG. Eighteen samples were randomly allocated to three study groups: bone scraper, diamond bur and extraoral removal with a scalpel.
J Dent
July 2024
Objectives: This study aimed to compare the effect the radiographic marker registration (RMR) and markerless tracing registration (MTR) on implant placement accuracy using a dynamic computer-assisted implant surgery system (dCAIS). Additionally, this study aimed to assess the surgical time and whether the implant location influences the accuracy of the two registration methods.
Methods: 136 dental implants were randomly allocated to the RMR or MTR group and were placed with a dCAIS in resin models.
Pterygoid hamular bursitis is an infrequent cause of orofacial pain due to a hypertrophic pterygoid hamulus. The pain is often referred to the pharynx, temporomandibular region and facial zone, and requires a differential diagnosis with other craniofacial entities. This paper describes a patient with pterygoid hamular bursitis that presented pain of neuropathic characteristics in the left retromolar region, associated with odynophagia and temporomandibular joint disorders.
View Article and Find Full Text PDFObjectives: To assess dental implant placement accuracy with a dynamic computer-assisted implant surgery (dCAIS) system and a freehand approach. Secondarily, to compare the patients' perception and quality of life (QoL) with the two approaches.
Methods: A double-arm randomized clinical trial was conducted.
Objectives: To assess the accuracy and patient reported outcome measures (PROMs) of the computer-guided "double factor" technique for treating fully edentulous patients.
Methods: A proof of concept prospective study was designed. Ten consecutive patients requiring full arch dental implant supported rehabilitation in a private practice were enrolled between October 2021 and March 2022.
Clin Oral Investig
March 2022
Objective: To determine the usefulness of Serum C-terminal telopeptide cross-link of type 1 collagen (sCTX) as a preoperative marker for predicting the risk of developing medication-related osteonecrosis of the jaws (MRONJ) after invasive oral surgery in patients on antiresorptive medication.
Materials And Methods: Two authors independently searched four electronic databases up to March 25, 2021, for case-control studies and prospective and retrospective cohort studies that assessed preoperative sCTX levels in patients taking antiresorptive medication who underwent oral surgery procedures. The main outcome was the number of MRONJ cases in patients with an sCTX value lower and higher than 150 pg/mL.
A novel computer-assisted surgery (CAS) technique that merges dynamic and static CAS approaches to treat completely edentulous patients with dental implants is described. Radiographic and surgical stents are designed with specific fiducial markers that are recognized by the static and dynamic CAS software program. During the surgical procedure, implants are placed following the static surgical guide and the indications from the dynamic navigation system.
View Article and Find Full Text PDFObjectives: To assess the accuracy of dynamic computer-aided implant surgery (dCAIS) systems when used to place dental implants and to compare its accuracy with static computer-aided implant surgery (sCAIS) systems and freehand implant placement.
Materials And Methods: An electronic search was made to identify all relevant studies reporting on the accuracy of dCAIS systems for dental implant placement. The following PICO question was developed: "In patients or artificial models, is dental implant placement accuracy higher when dCAIS systems are used in comparison with sCAIS systems or with freehand placement? The main outcome variable was angular deviation between the central axes of the planned and final position of the implant.