Article Abstract

Background: The utility of operating room extubation (ORE) after cardiac surgery over fast-track extubation (FTE) within 6 hours remains contested. We hypothesized ORE would be associated with equivalent rates of morbidity and mortality, relative to FTE.

Methods: Patients undergoing nonemergent cardiac surgery were identified in The Society of Thoracic Surgeons Adult Cardiac Surgery Database between July 2017 and December 2022. Only procedures with The Society of Thoracic Surgeons risk models were included. Risk-adjusted outcomes of ORE and FTE were compared by observed-to-expected ratios with 95% CIs aggregated over all procedure types, and ORE vs FTE adjusted odds ratios (ORs) specific to each procedure type using multivariable logistic regression. Analyzed outcomes were operative mortality, prolonged length of stay, composite reoperation for bleeding and reintubation, and composite morbidity and mortality.

Results: The study population of 669,099 patients across 1069 hospitals included 36,298 ORE patients in 296 hospitals. Risk-adjusted analyses found that ORE was associated with statistically similar or better results across each of the 4 outcomes and procedure subtypes. Notably, rates of postoperative mortality were significantly lower in ORE patients undergoing coronary artery bypass grafting (OR, 0.54; 95% CI, 0.46-0.65), aortic valve replacement (OR, 0.43; 95% CI, 0.24-0.77), and mitral valve replacement (OR, 0.48; 95% CI, 0.26-0.89).

Conclusions: Extubation in the OR was safe and effective in a selected patient population and may be associated with superior outcomes in coronary artery bypass, aortic valve replacement, and mitral valve replacement. These national data appear to confirm institutional experiences regarding the potential benefit of OR extubation. Further refinement of optimal populations may justify randomized investigation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.athoracsur.2024.05.033DOI Listing

Publication Analysis

Top Keywords

cardiac surgery
16
valve replacement
16
patients undergoing
12
society thoracic
12
thoracic surgeons
12
operating room
8
room extubation
8
ore associated
8
ore fte
8
ore patients
8

Similar Publications

Background: Evidence informing clinical guidelines assumes that all transcatheter aortic valve implantation (TAVI) devices have similar effectiveness, in other words, displaying a class effect across TAVI valves. We aimed to assess the comparative effectiveness of different TAVI platforms relative to other TAVI counterparts or surgical aortic valve replacement (SAVR).

Methods: MEDLINE/Embase/CENTRAL were searched from inception until April 2025, for randomized controlled trials comparing outcomes with different commercially available TAVI devices relative to other TAVI counterparts or SAVR.

View Article and Find Full Text PDF

Robotic mitral repair is often associated with longer ischaemic and cardiopulmonary bypass times, particularly early in the learning curve. We demonstrate a semi-continuous, three-suture technique for robotic annuloplasty that retains the mechanical principles of traditional interrupted sutures while leveraging the advantages of robotic precision and exposure. The use of pre-knotted sutures minimizes intra-cardiac knot tying, further enhancing procedural efficiency.

View Article and Find Full Text PDF

A Novel Technique to Extract Implanted Leads Using Simple Stylets and Reused Rotational Sheaths in Patients with a Cardiac Implantable Electronic Device.

Turk Kardiyol Dern Ars

September 2025

Division of Arrhythmia and Electrophysiology, Department of Cardiology, University of Health Sciences, Yuksek Ihtisas Cardiovascular Building, Ankara City Hospital, Ankara, Türkiye.

Objective: Transvenous lead extraction (TLE) is used in various clinical scenarios, such as device-related infections. Mechanically powered sheaths are one of the most commonly used tools for TLE procedures. We evaluated the procedural and clinical outcomes of a novel extraction technique for chronically implanted leads in the treatment of device-related infections.

View Article and Find Full Text PDF

Objectives: This study aimed to evaluate the predictive accuracy of Paediatric Risk of Mortality-III, Paediatric Index of Mortality-II, and Paediatric Logistic Organ Dysfunction scoring systems for major adverse events following congenital heart surgery.

Methods: This prospective observational study included patients under 18 years of age who were admitted to the ICU for at least 24 hours postoperatively following congenital heart surgery. Major adverse events were defined as a composite of 30-day mortality, ICU readmission, reintubation, acute neurologic events, requirement for extracorporeal membrane oxygenation, cardiac arrest requiring cardiopulmonary resuscitation, need for a permanent pacemaker, acute kidney injury, or unplanned reoperation.

View Article and Find Full Text PDF

Standardising cardiac CT-based personalised surgical planning and execution in congenital aortic valvar disease.

Cardiol Young

September 2025

Congenital Valve Procedural Planning Program, Division of Pediatric Cardiac Surgery, Cleveland Clinic Children's, and Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, OH, USA.

Background: Congenital aortic valvar disease represents a heterogeneous population with suboptimal surgical repair or replacement outcomes. We assess our approach and short-term outcomes in this population using cardiac CT evaluation for personalised surgical planning and execution.

Methods: We assessed patients who underwent aortic valvar surgery from February 2022 to August 2024.

View Article and Find Full Text PDF