Multispectral breast image grayscale and quality enhancement by repeated pair image registration & accumulation method.

Spectrochim Acta A Mol Biomol Spectrosc

Medical School of Tianjin University, Tianjin 300072, China; State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China. Electronic address:

Published: November 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Nowadays, for detecting breast cancer in its early stages, the focus is on multispectral transmission imaging. Frame accumulation is a promising technique to enhance the grayscale level of the multispectral transmission images. Still, during the image acquisition process, human respiration or camera jitter causes the displacement of the frame's sequence which leads to the loss of accuracy and image quality of the frame accumulated image is reduced. In this article, we have proposed a new method named "repeated pair image registration and accumulation "to resolve the issue. In this method first pair of images from the sequence is first registered and accumulated followed by the next pair to be registered and accumulated. Then these two accumulated frames are registered and accumulated again. This process is repeated until all the frames from the sequence are processed and the final image is obtained. This method is tested on the sequence of breast frames taken at 600 nm, 620 nm, 670 nm, and 760 nm wavelength of light and proved the enhancement of quality, accuracy, and grayscale by various mathematical assessments. Furthermore, the processing time of our proposed method is very low because descent gradient optimization algorithm is used here for image registration purpose. This optimization algorithm has high speed as compared to other methods and is verified by registering a single image of each wavelength by three different methods. It has laid the foundations of early detection of breast cancer using multispectral transmission imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2024.124558DOI Listing

Publication Analysis

Top Keywords

image registration
12
multispectral transmission
12
registered accumulated
12
image
9
pair image
8
registration accumulation
8
breast cancer
8
transmission imaging
8
proposed method
8
optimization algorithm
8

Similar Publications

Background: In clinical practice, digital subtraction angiography (DSA) often suffers from misregistration artifact resulting from voluntary, respiratory, and cardiac motion during acquisition. Most prior efforts to register the background DSA mask to subsequent postcontrast images rely on key point registration using iterative optimization, which has limited real-time application.

Purpose: Leveraging state-of-the-art, unsupervised deep learning, we aim to develop a fast, deformable registration model to substantially reduce DSA misregistration in craniocervical angiography without compromising spatial resolution or introducing new artifacts.

View Article and Find Full Text PDF

Digital twins in nuclear medicine: A proposition of a modular pipeline for dosimetry protocol optimization in molecular radiotherapy.

Comput Struct Biotechnol J

August 2025

Institut de Recherche en Cancérologie de Montpellier (IRCM), Équipe Labellisée Ligue Contre le Cancer, INSERM U1194, Université de Montpellier, Institut régional du Cancer de Montpellier (ICM), Montpellier, France.

Digital twins (DTs) are emerging tools for simulating and optimizing therapeutic protocols in personalized nuclear medicine. In this paper, we present a modular pipeline for constructing patient-specific DTs aimed at assessing and improving dosimetry protocols in PRRT such as therapy. The pipeline integrates three components: (i) an anatomical DT, generated by registering patient CT scans with an anthropomorphic model; (ii) a functional DT, based on a physiologically-based pharmacokinetic (PBPK) model created in SimBiology; and (iii) a virtual clinical trial module using GATE to simulate particle transport, image simulation, and absorbed dose distribution.

View Article and Find Full Text PDF

Objective: This study evaluates cardiac function in older adults with T2DM and preserved LVEF using two-dimensional speckle-tracking echocardiography to explore the risk factors associated with subclinical left ventricular systolic dysfunction (GLS <18%) in this population.

Methods: All patients (n = 87, aged 60 years and above) and controls (n = 20) underwent clinical assessment and echocardiography, including GLS assessment.

Results: Univariate analysis identified gender (OR 3.

View Article and Find Full Text PDF

Background: Understanding respiratory motions of liver and its surrogate organs is crucial for precise dose delivery in liver cancer radiotherapy. Although these motions have been studied for respiratory motion management in the supine posture, few studies have quantified them and evaluated their correlations in the upright posture.

Purpose: This study quantified the respiratory motions of liver and surrogate organs and evaluated the correlations between the liver motions and surrogate signals for respiratory motion monitoring in both the supine and upright postures.

View Article and Find Full Text PDF

Lightweight hybrid Mamba2 for unsupervised medical image registration.

Med Phys

September 2025

School of Computer, Electronics and Information, Guangxi University, Nanning, China.

Background: Deformable medical image registration is a critical task in medical imaging-assisted diagnosis and treatment. In recent years, medical image registration methods based on deep learning have made significant success by leveraging prior knowledge, and the registration accuracy and computational efficiency have been greatly improved. Models based on Transformers have achieved better performance than convolutional neural network methods (ConvNet) in image registration.