Article Abstract

New-generation transcatheter heart valves have significantly improved technical success and procedural safety of transcatheter aortic valve implantation (TAVI) procedures; however, the incidence of permanent pacemaker implantation (PPI) remains a concern. This study aimed to assess the role of anatomic annulus features in determining periprocedural conduction disturbances leading to new PPI after TAVI using the last-generation Edwards SAPIEN balloon-expandable valves. In the context of a prospective single-center registry, we integrated the clinical and procedural predictors of PPI with anatomic data derived from multislice computed tomography. A total of 210 consecutive patients treated with balloon-expandable Edwards transcatheter heart valve were included in the study from 2015 to 2023. Technical success was achieved in 197 procedures (93.8%), and 26 patients (12.4%) required new PPI at the 30-day follow-up (median time to implantation 3 days). At the univariable logistic regression analysis, preprocedural right bundle branch block (odds ratio [OR] 2.24, 95% confidence interval [CI] 1.01 to 4.97, p = 0.047), annulus eccentricity ≥0.25 (OR 5.43, 95% CI 2.21 to 13.36, p <0.001), calcium volume at annulus of the right coronary cusp >48 mm (OR 2.60, 95% CI 1.13 to 5.96, p = 0.024), and prosthesis implantation depth greater than membranous septum length (OR 2.17, 95% CI 1.10 to 4.28, p = 0.026) were associated with new PPI risk. In the multivariable analysis, preprocedural right bundle branch block (OR 2.81, 95% CI 1.01 to 7.85, p = 0.049), annulus eccentricity ≥0.25 (OR 4.14, 95% CI 1.85 to 9.27, p <0.001), and annulus calcium >48 mm (OR 2.89, 95% CI 1.07 to 7.82, p = 0.037) were confirmed as independent predictors of new PPI. In conclusion, specific anatomic features of the aortic valve annulus might have an additive role in determining the occurrence of conduction disturbances in patients who underwent TAVI with balloon-expandable valves. This suggests the possibility to use multislice computed tomography to improve the prediction of post-TAVI new PPI risk.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2024.05.034DOI Listing

Publication Analysis

Top Keywords

aortic valve
12
permanent pacemaker
8
pacemaker implantation
8
transcatheter aortic
8
valve implantation
8
transcatheter heart
8
technical success
8
conduction disturbances
8
balloon-expandable valves
8
predictors ppi
8

Similar Publications

[The TAVI heart team].

Herz

September 2025

Department of Cardiology, Heart Center Leipzig, University of Leipzig, Strümpellstraße 39, 04289, Leipzig, Deutschland.

Since the earliest studies on transcatheter aortic valve implantation (TAVI), the heart team concept has been an integral component of treatment planning for patients with aortic valve stenosis (AS). The primary objective is to ensure patient-specific, guideline-based treatment through the structured involvement of all relevant medical disciplines. The TAVI heart team is strongly recommended with a class I indication in both European and US clinical guidelines.

View Article and Find Full Text PDF

Introduction: Whilst aortic stenosis remains the most prevalent valvular abnormality, the management of asymptomatic severe aortic stenosis remains a clinical challenge. Recently, two randomised-controlled trials (RCTs) - EVOLVED (Early Intervention in Patients With Asymptomatic Severe Aortic Stenosis and Myocardial Fibrosis) and Early TAVR (Transcatheter Aortic-Valve Replacement for Asymptomatic Severe Aortic Stenosis) - have been published, alongside an extended follow-up from the AVATAR (Aortic Valve Replacement Versus Conservative Treatment in Asymptomatic Severe Aortic Stenosis) study.

Evidence Acquisition: In response, we conducted a systematic review of PubMed, Ovid, and Cochrane databases, identifying RCTs up to October 29, 2024, that compared early intervention with conventional management.

View Article and Find Full Text PDF

We describe a modified Park's stitch technique incorporating systematic free margin alignment to achieve complete elimination of aortic regurgitation in patients with a left ventricular assist device. The technique involves a two-step approach: first, free margin alignment of all three cusps using single interrupted 6-0 polypropylene sutures placed at the nodules of Arantius to achieve precise coaptation, followed by conventional Park's stitch using mattress sutures with autologous pericardial pledgets for central closure. The alignment sutures remain in place to provide reinforcement.

View Article and Find Full Text PDF

Aortic valve stenosis is a progressive and increasingly prevalent disease in older adults, with no approved pharmacologic therapies to prevent or slow its progression. Although genetic risk factors have been identified, the contribution of epigenetic regulation remains poorly understood. Here, we demonstrated that histone deacetylase 3 (HDAC3) maintains aortic valve structure by suppressing mitochondrial biogenesis and preserving extracellular matrix integrity in valvular interstitial fibroblasts.

View Article and Find Full Text PDF

Objective: Valve selection in acute type A aortic dissection (ATAAD) requiring aortic root replacement is challenging given the clinical acuity, unknown patient preferences, risk of surgical bleeding, and limited life expectancy. We sought to identify long-term outcomes of mechanical versus bioprosthetic aortic root replacement in young patients with ATAAD.

Methods: Retrospective review of our institution's database of ATAAD was conducted to identify patients aged 65 years and younger who underwent mechanical Bentall (mech-Bentall) or bioprosthetic Bentall (bio-Bentall) for ATAAD from 2002 to 2022.

View Article and Find Full Text PDF