98%
921
2 minutes
20
Objectives: The aim of this study to investigate the safety and effectiveness of performing the hanging arm test during surgical treatment for elbow varus posteromedial rotatory instability (VPMRI) to assess elbow stability and determine whether to repair the lateral ulnar collateral ligament (LUCL).
Methods: In a retrospective study from August 2014 to March 2019, 27 patients with VPMRI who had a negative result in the hanging arm test after fixation of coronoid fracture were selected. Intraoperative bleeding, operative time, elbow range of motion (ROM), and complications were recorded. Elbow function was evaluated with the Mayo elbow performance score (MEPS) and the disabilities of the arm, shoulder, and hand (DASH) score.
Results: The operation time was 85.9 ± 11.06 min (range 65-110). The intraoperative blood loss was 70.7 ± 9.31 ml (range 60-100). At the last follow-up, the elbow joint averaged 73.8° ± 2.931° in pronation, 78.9° ± 2.941° in supination, 7.2° ± 3.207° in extension, and 123.3° ± 6.651° in flexion. The MEPS score was 90.7 ± 4.36 (range 74-95), and the DASH score was 9.8 ± 2.58 (range 6.67-13.3). One patient presented with symptoms of ulnar nerve entrapment 2 months after operation and was treated with ulnar nerve release. The symptom of numbness went away completely 1 week after operation. No complications such as wound infection, arthritis, or chronic instability of the elbow were found in the other patients.
Conclusion: Our findings suggest that not all VPMRI patients need the LUCL to be repaired, and the hanging arm test is a safe and reliable method to assess whether to repair the LUCL in the treatment of elbow VPMRI.
Level Of Evidence: Level IV; Retrospective studies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11130092 | PMC |
http://dx.doi.org/10.1007/s43465-024-01128-0 | DOI Listing |
Prosthet Orthot Int
August 2025
University of Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia.
Stiffness of ankle-foot orthoses (AFOs) has been assessed using many methods; however, results are unstandardized due to varied testing conditions such as range of motion and speed. Therefore, the aim of this scoping review was to provide a state-of-the-space review of the studies that investigate AFO ankle stiffness in the sagittal plane and then provide insight into the details of the developed devices and protocols. Six electronic databases (MEDLINE, SCOPUS, Web of Science, CINAHL, EMBASE, and IEEE Xplore) were searched for studies from when indexing began to April 2024.
View Article and Find Full Text PDFJ Pediatr Soc North Am
August 2025
Harvard Medical School, Boston Children's Hospital, Boston, MA, USA.
Unlabelled: This chapter aims to provide a comprehensive review of the techniques and challenges associated with applying upper extremity casts in pediatric patients. The chapter, along with its accompanying figures and video clips, serves as an introductory guide to pediatric orthopaedic cast application for trainees. Generally, casts are used to preserve appropriate alignment rather than to create improved alignment.
View Article and Find Full Text PDFFront Psychol
July 2025
Sport and Health Research Center, Shanghai YangZhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), Physical Education Department, Tongji University, Shanghai, China.
Objective: Achieving greater pre-jump elevation is essential for trampoline gymnasts to attain high-level competition performance. This study aimed to explore the key influencing factors of pre-jump height in juvenile trampoline gymnasts, thereby providing a rationale for training programs and talent selection criteria.
Methods: A mixed-methods approach was adopted.
Rev Neurol
June 2025
Facultad de Medicina de la Universidad Autónoma de Nuevo León, Monterrey, NL 64460, México.
Introduction: Stroke is highly prevalent worldwide; however, associated symptoms and risk factors are unknown in the general population. Our aim was to describe the knowledge of early signs of stroke and its association with the risk of stroke at 5 and 10 years according to the "Stroke Riskometer™".
Subjects And Methods: This was an observational, descriptive, cross-sectional study, including adults in the Neurology outpatient clinic of the University Hospital "Dr.
PLOS Digit Health
June 2025
Department of Public Health and Primary Care, University of Cambridge, Cambridge, United Kingdom.
Wrist photoplethysmogram (PPG) signals are widely used for physiological monitoring in consumer devices. However, the PPG is highly susceptible to noise, which can reduce the accuracy of monitored parameters. The aim of this study was to identify factors which influence PPG signal quality.
View Article and Find Full Text PDF