Article Abstract

Purpose: The purpose of this study was to evaluate and compare the diagnostic accuracy of modalities used to aid the diagnosis of aseptic knee arthroplasty loosening.

Methods: A comparative diagnostic test accuracy systematic review and meta-analysis was conducted following the Cochrane and PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. PubMed, EMBASE and Cochrane databases were searched for original articles evaluating diagnostic modalities up to March 2024. Included studies compared the modality (index test) to the intraoperative finding as reference test. The QUADAS-C (Quality Assessment of Diagnostic Accuracy Studies-Comparative) tool was used to assess the quality of the included studies. The GRADE (Grading of Recommendations, Assessment, Development and Evaluation) approach was used to evaluate the certainty of evidence. Level of evidence was evaluated using the Oxford Levels of Evidence tool. The primary outcome was the summary of diagnostic accuracy metrics for each modality as demonstrated by a summary receiver-operating characteristic (SROC) curve.

Results: The search yielded 467 articles. Of these, 14 articles were included. These 14 articles evaluated a total of five different diagnostic modalities: bone scintigraphy (three studies, 146 cases), 18-fluorodeoxyglucose positron emission tomography (two studies, 50 cases), single-photon emission computed tomography combined with computed tomography (SPECT/CT) (seven studies, 371 cases), radionuclide arthrogram (three studies, 196 cases) and magnetic resonance imaging (MRI) (one study, 116 cases). Nine studies exhibited a high risk of bias in patient selection, and all studies showed a high risk of bias related to the reference test. The majority of the included studies were classified as Level III evidence, leading to an overall low level of certainty in the evidence. The most accurate tests, as demonstrated by the SROC analysis, were MRI and SPECT/CT, with sensitivities ranging from 0.00 to 1.00 and 0.33 to 1.00 and specificities between 0.31-1.00 and 0.00-1.00, respectively.

Conclusions: This review and meta-analysis evaluated available diagnostic modalities to aid the diagnosis of knee arthroplasty loosening and based on a low certainty of evidence suggests that MRI and SPECT/CT are currently the most accurate modalities available to aid the diagnosis of aseptic loosening of knee arthroplasty components.

Level Of Evidence: Level III.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ksa.12206DOI Listing

Publication Analysis

Top Keywords

certainty evidence
16
diagnostic accuracy
16
knee arthroplasty
16
mri spect/ct
12
review meta-analysis
12
modalities aid
12
aid diagnosis
12
diagnostic modalities
12
included studies
12
diagnostic
9

Similar Publications

Background: Evidence informing clinical guidelines assumes that all transcatheter aortic valve implantation (TAVI) devices have similar effectiveness, in other words, displaying a class effect across TAVI valves. We aimed to assess the comparative effectiveness of different TAVI platforms relative to other TAVI counterparts or surgical aortic valve replacement (SAVR).

Methods: MEDLINE/Embase/CENTRAL were searched from inception until April 2025, for randomized controlled trials comparing outcomes with different commercially available TAVI devices relative to other TAVI counterparts or SAVR.

View Article and Find Full Text PDF

This systematic review and meta-analysis aimed to evaluate the long-term clinical outcomes of regenerative procedures compared with access flap surgery for the treatment of intrabony defects, with a minimum follow-up period of 5 years. A systematic review protocol following PRISMA guidelines was conducted. Both electronic and manual searches were conducted to identify randomized clinical trials (RCTs) on regenerative treatment of deep intrabony defects (≥3 mm) with a follow-up of at least 5 years.

View Article and Find Full Text PDF

This systematic review examined the impact of unemployment and re-employment on mental health problems (depression, anxiety and psychological distress) among working-age adults. We searched MEDLINE, Embase, APA PsycINFO and Web of Science (January 2012-March 2024) and included studies from a prior meta-analysis (1990-2012). Risk of bias was assessed using the Newcastle-Ottawa Scale.

View Article and Find Full Text PDF

Ketamine and Esketamine for Late-Life Depression: A Systematic Review of Efficacy, Safety, and Tolerability.

Am J Geriatr Psychiatry

August 2025

Mood Disorder and Psychopharmacology Unit (RS, JKT, CED, RSM), University Health Network, Toronto, Ontario, Canada; Department of Psychiatry, University of Toronnto, Toronto, ON, Canada; Department of Pharmacology and Toxicology, University of Toronto, ON, Canada. Electronic address: roger.mcintyre@

Ketamine has emerged as a promising treatment for major depression, though its efficacy and safety remain incompletely characterized in older adults. This systematic review synthesizes current evidence for ketamine in geriatric depression. A search of PubMed, EMBASE, and PsycINFO was conducted.

View Article and Find Full Text PDF

Objectives: This study evaluated the effects of proximal core training on biomechanical risk factors and strength parameters in individuals at high risk of anterior cruciate ligament (ACL) injury (specifically: those exhibiting pathological movement patterns, neuromuscular deficits or biomechanical risk factors) and compared direct versus indirect interventions. We hypothesised that targeted training enhances dynamic knee stabilisation and hip control during high-risk manoeuvres, with direct approaches providing superior biomechanical benefits through neuromuscular control optimisation.

Design: Systematic review and meta-analysis using the Grading of Recommendation, Assessment, Development and Evaluation (GRADE) approach.

View Article and Find Full Text PDF