Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Low vision and blindness are increasing public health issues impacting individuals' quality of life. During clinical low-vision services, vision rehabilitation is crucial for enhancing daily living skills and improving life quality. Low-vision and rehabilitation (LVR) services encompass comprehensive measures that aid visually disabled individuals in restoring function, autonomy, and social participation. Such holistic management requires a multidisciplinary approach, facilitating adaptation to environmental and sociocultural changes. However, the lack of awareness about the principles and practices of LVR services poses a major hindrance to setting up such a special clinic in the eye hospital. This article is about a consensus statement on the guidelines for establishing LVR services focusing on basic requirements, especially in low-resource countries. The present recommendation to set up an LVR clinic was made after group discussions and debates among various experts and stakeholders during the National Workshop on Strengthening Low-Vision and Rehabilitation Services organized at Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi. The event was participated by many ophthalmologists and optometrists coming from across the country. The recommendations required at the tertiary level are outlined under the four headings: Human resources and training: two ophthalmologists, that is, a low vision specialist or a well-experienced in low vision and one who has received one-week orientation and training, one optometrist, one rehabilitation supervisor, and two rehabilitation assistants; Assessment equipment: basic screening and diagnostic; Assistive devices for low vision, including, digital and non-digital; Assistive devices for rehabilitation, and methods for records maintenance. The institution may not follow strictly the present guidelines but will provide an idea on LVR services initiation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11668197PMC
http://dx.doi.org/10.4103/IJO.IJO_2712_23DOI Listing

Publication Analysis

Top Keywords

low vision
16
lvr services
16
low-vision rehabilitation
12
rehabilitation services
8
assistive devices
8
rehabilitation
7
services
7
vision
5
lvr
5
guidelines setting
4

Similar Publications

Optically Controlled Memristor Enabling Synergistic Sensing-Memory-Computing for Neuromorphic Vision Systems.

Adv Mater

September 2025

Key Laboratory of Brain-Like Neuromorphic Devices and Systems of Hebei Province, College of Electronic and Information Engineering, Hebei University, Baoding, 071002, China.

Neuromorphic Visual Devices hold considerable promise for integration into neuromorphic vision systems that combine sensing, memory, and computing. This potential arises from their synergistic benefits in optical signal detection and neuro-inspired computational processes. However, current devices face challenges such as insufficient light/dark resistance ratios, mismatched transient photo-response, and volatile retention characteristics, limiting their adaptability to complex artificial vision systems.

View Article and Find Full Text PDF

Nanoparticle labels enable colorimetric point-of-care devices for rapid, low-cost diagnosis and health monitoring. Accurate interpretation of colorimetric assays relies on reliable perception of differences in quantitative color attributes such as hue, chromaticity, and saturation. This study examined interactions between physical factors such as nanoparticle shape, illumination, and sample environment, and biological factors affecting color vision deficit and optical signal processing that influenced perceived color difference.

View Article and Find Full Text PDF

Comprehensive Rehabilitation for Autosomal Dominant Retinitis Pigmentosa: A Case Report.

Case Rep Ophthalmol Med

September 2025

Department of Ophthalmology and Visual Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.

A 62-year-old female with retinitis pigmentosa presented for a low vision rehabilitation evaluation. An updated spectacle prescription, filters, and task lighting were beneficial, but the patient was left with outstanding needs. She noted that she had lost her independence and felt trapped within her own home with nobody around who could fully understand her situation.

View Article and Find Full Text PDF

Background: Patients with clear cell renal cell carcinoma (ccRCC) often undergo organ resection, with treatment strategies based on recurrence risk. Current metastatic potential assessments rely on the WHO/ISUP grading system, which is subject to interobserver variability.

Methods: We developed an artificial intelligence (AI) model to classify cells according to contemporary grading rules and evaluated the prognostic significance of tumor cell profiles, particularly focusing on cells with prominent nucleoli.

View Article and Find Full Text PDF

Amorphous silicon resistors enable smaller pixels in photovoltaic retinal prosthesis.

J Neural Eng

September 2025

Hansen Experimental Physics Laboratory, Stanford University, 452 Lomita Mall, Stanford, California, 94305, UNITED STATES.

Clinical trials of the photovoltaic subretinal prosthesis PRIMA demonstrated feasibility of prosthetic central vision with resolution matching its 100 μm pixel width. To improve prosthetic acuity further, pixel size should be decreased. However, there are multiple challenges, one of which is related to accommodating a compact shunt resistor within each pixel that discharges the electrodes between stimulation pulses and helps increase the contrast of the electric field pattern.

View Article and Find Full Text PDF