A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

The standardized training and assessment system for magnetically controlled capsule gastroscopy (with video). | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Aim: To explore the feasibility of a standardized training and assessment system for magnetically controlled capsule gastroscopy (MCCG).

Methods: The results of 90 trainees who underwent the standardized training and assessment system of the MCCG at the First Affiliated Hospital of Xi'an Jiaotong University from May 2020 to November 2023 was retrospectively analyzed. The trainees were divided into three groups according to their medical backgrounds: doctor, nurse, and non-medical groups. The training and assessment system adopted the '7 + 2' mode, seven days of training plus two days of theoretical and operational assessment. The passing rates of theoretical, operational, and total assessment were the primary outcomes. Satisfaction and mastery of the MCCG was checked.

Results: Ninety trainees were assessed; theoretical assessment's passing rates in the three groups were 100%. The operational and total assessment passing rates were 100% (25/25), 97.92% (47/48), and 94.12% (16/17), for the doctor, nurse, and non-doctor groups respectively, with no significant difference (χ = 1.741,  = 0.419). No bleeding or perforation occurred during the procedure. Approximately, 96.00% (24/25), 95.83% (46/48), and 94.12% (16/17) of the doctor, nurse and non-medical groups anonymously expressed great satisfaction, respectively, without statistically significant difference (χ = 0.565,  = 1.000). The average follow-up time was 4-36 months, and 87 trainees (96.67%) had mastered the operation of the MCCG in daily work.

Conclusions: Standardized training and assessment of magnetically controlled capsule endoscopists is effective and feasible. Additionally, a strict assessment system and long-term communication and learning can improve teaching effects.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00365521.2024.2354424DOI Listing

Publication Analysis

Top Keywords

training assessment
20
assessment system
20
standardized training
16
magnetically controlled
12
controlled capsule
12
doctor nurse
12
passing rates
12
assessment
9
system magnetically
8
capsule gastroscopy
8

Similar Publications