Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: When an anorectal foreign body is found, its composition and shape should be evaluated, and a timely and effective treatment plan should be developed based on the patient's symptoms to avoid serious complications such as intestinal perforation caused by displacement of the foreign body.

Case Summary: A 54-year-old male was admitted to our outpatient clinic on June 3, 2023, due to a rectal foreign body that had been embedded for more than 24 h. The patient reported using a glass electrode tube to assist in the recovery of prolapsed hemorrhoids, however, the electrode tube was inadvertently inserted into the anus and could not be removed by the patient. During hospitalization, the patient underwent surgery, and the foreign body was dragged into the rectum with the aid of colonoscopy. The anus was dilated with a comb-type pulling hook and an anal fistula pulling hook to widen the anus and remove the foreign body, and the local anal symptoms were then relieved with topical drugs. The patient was allowed to eat and drink, and an entire abdominal Computed tomography (CT) and colonoscopy were reviewed 3 d after surgery. CT revealed no foreign body residue and colonoscopy showed no metal or other residues in the colon and rectum, and no apparent intestinal tract damage.

Conclusion: The timeliness and rationality of the surgical and therapeutic options for this patient were based on a literature review of the clinical signs and conceivable conditions in such cases. The type, material and the potential risks of rectal foreign bodies should be considered.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11036519PMC
http://dx.doi.org/10.12998/wjcc.v12.i11.1990DOI Listing

Publication Analysis

Top Keywords

foreign body
24
foreign
8
rectal foreign
8
electrode tube
8
pulling hook
8
body
6
patient
5
colonoscopy-assisted removal
4
removal impaction
4
impaction foreign
4

Similar Publications

Disruption of the central venous port catheter was identified on the chest radiograph of a 36-year-old woman who had undergone chemotherapy following resection of her colon cancer. Computed tomography revealed that the catheter was impacted in the peripheral pulmonary artery. Instead of using a snare wire, a balloon catheter was inserted into the lumen of the disrupted catheter due to its tight lodging in the pulmonary artery.

View Article and Find Full Text PDF

Foreign body ingestion in children, especially those aged 6 months to 3 years, is a common clinical concern. While most objects pass through the gastrointestinal tract uneventfully, some may result in obstruction and necessitate surgical intervention. We report a rare case of a 10-year-old child with autism who presented with small bowel obstruction following ingestion of a rubber feeding bottle nipple.

View Article and Find Full Text PDF

The development of continuous-release devices or injectables for the long-term delivery of biologics is of great interest, especially monoclonal antibodies (mAbs) that require frequent, high-dose injections. Preclinical testing of these technologies in murine models is necessary for clinical translation; however, xenogeneic responses to the mAb and foreign body responses to the implants or injectables can confound results. Immune system knockout (KO) models that affect immune cells are often used in these experiments, but the effects of KO models on mAb pharmacokinetics (PK) are not well characterized.

View Article and Find Full Text PDF

ChroMOS: a "microwire-like" CMOS neural probe for chronic neural recordings in mice.

Biosens Bioelectron

September 2025

Microtechnology for Neuroelectronics Unit (NetS(3) lab), Fondazione Istituto Italiano di Tecnologia, Genova, Italy.

Achieving stable and continuous monitoring of signals of numerous single neurons in the brain faces the conflicting challenge of increasing the microelectrode count while minimizing cross-sectional shank dimensions to reduce tissue damage, foreign-body-reaction and maintain signal quality. Passive probes need to route each microelectrode individually to external electronics, thus increasing shank size and tissue-damage as the number of electrodes grows. Active complementary metal-oxide-semiconductor (CMOS) probes overcome the limitation in electrode count and density with on-probe frontend, addressing and multiplexing circuits, but current probes have relatively large shank widths of 70 - 100 μm.

View Article and Find Full Text PDF

This study presents a medico-legal case study of an infant who died as a result of intestinal volvulus, a rare but severe complication secondary to the ingestion of multiple magnets and button batteries. The mutual attraction of magnets through adjacent intestinal loops, compounded by the corrosive effects of button batteries, can precipitate rapid and irreversible damage to the gastrointestinal wall. A comprehensive review of the literature on documented pediatric cases involving the ingestion of magnets and button batteries was undertaken to compare the spectrum and frequency of complications.

View Article and Find Full Text PDF