Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

An all-solid fiber-tip Fabry-Perot interferometer (FPI) coated with a nickel film is proposed and experimentally verified for magnetic field sensing with high sensitivity. It is fabricated by splicing a segment of a thin-wall capillary tube to a standard single-mode fiber (SMF), then inserting a tiny segment of fiber with a smaller diameter into the capillary tube, and creating an ultra-narrow air-gap at the SMF end to form an FPI. When the device is exposed to magnetic field, the capillary tube is strained due to the magnetostrictive effect of the nickel film coated on its outer surface. In addition, owing to the unique breakpoint sensitivity-enhancement structure of the air-gap FPI, the elongation of the capillary tube whose length is over 100 times longer than the air-gap width is entirely transferred to the cavity length change of the FPI, and the sensor is extremely sensitive to the magnetic field as proved by our experiments, achieving a high sensitivity of up to 2.236 nm/mT for a linear magnetic field range from 40 to 60 mT, as well as a low-temperature cross-sensitivity of 56 µT/°C. The all-solid stable structure, compact size (total length of ∼3.0 mm), and reflective working mode with high magnetic field sensitivity indicate that this sensor has good application prospects.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.521138DOI Listing

Publication Analysis

Top Keywords

magnetic field
24
capillary tube
16
fabry-perot interferometer
8
nickel film
8
high sensitivity
8
magnetic
6
field
6
all-solid highly
4
highly sensitive
4
sensitive fiber-tip
4

Similar Publications

Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.

View Article and Find Full Text PDF

In the visual cortices, receptive fields (RFs) are arranged in a gradient from small sizes in the center of the visual field to the largest sizes at the periphery. Using functional magnetic resonance imaging (fMRI) mapping of population RFs, we investigated RF adaptation in V1, V2, and V3 in patients after long-term photoreceptor degeneration affecting the central (Stargardt disease [STGD]) and peripheral (Retinitis Pigmentosa [RP]) regions of the retina. In controls, we temporarily limited the visual field to the central 10° to model peripheral loss.

View Article and Find Full Text PDF

Streptococcus mutans, a key cause of dental caries, is not treated by conventional toothpaste, brushing, flossing, or antiseptic mouthwashes. This necessitates the development of enriched toothpaste. Cyanobacteria-derived phycoerythrin (PE) has antioxidant and antibacterial properties.

View Article and Find Full Text PDF

The human kidneys play a pivotal role in regulating blood pressure, water, and salt homeostasis, but assessment of renal function typically requires invasive methods. Deuterium metabolic imaging (DMI) is a novel, noninvasive technique for mapping tissue-specific uptake and metabolism of deuterium-labeled tracers. This study evaluates the feasibility of renal DMI at 7-Tesla (7T) to track deuterium-labeled tracers with high spatial and temporal resolution, aiming to establish a foundation for potential clinical applications in the noninvasive investigation of renal physiology and pathophysiology.

View Article and Find Full Text PDF

A new whole-body exposure facility for a randomized, double-blind, cross-over provocation study investigating possible effects of 50 Hz magnetic field exposure on sleep and markers of Alzheimer's disease has been developed and dosimetrically analyzed. The exposure facility was custom-tailored for the sleep laboratory where the study was carried out and enables magnetic flux densities of up to 30 μT with a maximum field inhomogeneity of less than ± 20%. Exposure is applied fully software-controlled and in a blinded and randomized manner.

View Article and Find Full Text PDF