Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Dysphagia is common in amyotrophic lateral sclerosis (ALS) patients, often requiring percutaneous endoscopic gastrostomy (PEG) for enteral nutrition. We retrospectively analyzed data from 188 Korean patients with ALS who underwent PEG tube insertion at five-time points: symptom onset (t), diagnosis (t), recommended time for gastrostomy (t), PEG insertion (t), and one-year post-insertion (t). The recommended time point for gastrostomy (T for gastrostomy) was defined as the earlier time point between a weight loss of more than 10% and advanced dysphagia indicated by the ALSFRS-R swallowing subscore of 2 or less. The T for gastrostomy was reached at 22 months after symptom onset, followed by PEG insertion at 30 months, resulting in an 8-month delay. During the delay, the ALSFRS-R declined most rapidly at 1.7 points/month, compared to 0.8 points/month from symptom onset to diagnosis, 0.7 points/month from diagnosis to T for gastrostomy, and 0.6 points/month after the PEG insertion. It is crucial to discuss PEG insertion before significant weight loss or severe dysphagia occurs and minimize the delay between the recommended time for gastrostomy and the actual PEG insertion. A stratified and individualized multidisciplinary team approach with careful symptom monitoring and proactive management plans, including early PEG insertion, should be prioritized to improve patient outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10965990PMC
http://dx.doi.org/10.1038/s41598-024-56752-5DOI Listing

Publication Analysis

Top Keywords

peg insertion
24
symptom onset
12
recommended time
12
percutaneous endoscopic
8
gastrostomy
8
endoscopic gastrostomy
8
insertion
8
amyotrophic lateral
8
lateral sclerosis
8
peg
8

Similar Publications

Determination of alcohol concentration in a single drop blood obtained via fingertip using gas chromatography/mass spectrometry coupled with solid-phase microextraction.

Leg Med (Tokyo)

September 2025

Department of Analytical Chemistry, School of Pharmacy and Pharmaceutical Sciences, Hoshi University, 2-4-41, Ebara, Shinagawa-ku, Tokyo 142-8501, Japan.

This study investigated headspace solid-phase microextraction (HS-SPME)-gas chromatography (GS)/mass spectrometry as a low-complexity method for accurate measurement of blood alcohol concentration (BAC) changes in humans over time following alcohol consumption. The aim was to develop an analytical method that would require as small blood samples as possible-smaller than that required for the conventional method-thereby reducing the burden on the subject. Polyethylene glycol (PEG) was used as the fiber material for SPME, and a DB-WAX capillary column was used for GC.

View Article and Find Full Text PDF

Dissociable PEGylation alleviates Kupffer cells capture of PEGylated liposomal doxorubicin.

Int J Pharm

October 2025

Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai 200031, PR China. Electronic address:

Surface modification by polyethylene glycol (PEG) is valuable to assist clinical translation of lipid-based nanomedicines but suffering "PEG dilemma" due to unavoidable interaction with anti-PEG antibodies. Considering high detection rates of pre-existing anti-PEG antibodies in clinic, it is urgent to enrich PEGylation strategies to resist anti-PEG antibodies and improve drug delivery efficiency. Herein, regulatory effects of different PEGylation strategies on in vivo performance of PEGylated liposomes and related mechanisms were explored.

View Article and Find Full Text PDF

Atrial fibrillation and cerebral amyloid angiopathy often coexist in older adults and can make post-stroke management particularly challenging, especially when further complicated by comorbidities such as cirrhosis. We present the case of a 78-year-old man admitted with an acute ischaemic stroke and persistent dysphagia. He was initially fed via a nasogastric tube, but ongoing swallowing difficulties led to the insertion of a percutaneous endoscopic gastrostomy (PEG) tube.

View Article and Find Full Text PDF

Active Touch Sensing for Robust Hole Detection in Assembly Tasks.

Sensors (Basel)

July 2025

Humanoid and Cognitive Robotics Lab, Jožef Stefan Institute, 1000 Ljubljana, Slovenia.

In this paper, we propose an active touch sensing algorithm designed for robust hole localization in 3D objects, specifically aimed at assembly tasks such as peg-in-hole operations. Unlike general object detection algorithms, our solution is tailored for precise localization of features like hole openings using sparse tactile feedback. The method builds on a prior 3D map of the object and employs a series of iterative search algorithms to refine localization by aligning tactile sensing data with the object's shape.

View Article and Find Full Text PDF

The prognosis of adult patients with acute lymphoblastic leukemia (ALL) has improved with the incorporation of pediatric-inspired regimens that contain PEGylated asparaginase (PEG-Asp). However, PEG-Asp administration is associated with an increased rate of thrombosis. Data regarding the benefits of antithrombin (AT) repletion and prophylactic anticoagulation in adults receiving PEG-Asp-based regimens are limited.

View Article and Find Full Text PDF