98%
921
2 minutes
20
Nonoscillatory measures of brain activity such as the spectral slope and Lempel-Ziv complexity are affected by many neurological disorders and modulated by sleep. A multitude of frequency ranges, particularly a broadband (encompassing the full spectrum) and a narrowband approach, have been used especially for estimating the spectral slope. However, the effects of choosing different frequency ranges have not yet been explored in detail. Here, we evaluated the impact of sleep stage and task engagement (resting, attention, and memory) on slope and complexity in a narrowband (30-45 Hz) and broadband (1-45 Hz) frequency range in 28 healthy male human subjects (21.54 ± 1.90 years) using a within-subject design over 2 weeks with three recording nights and days per subject. We strived to determine how different brain states and frequency ranges affect slope and complexity and how the two measures perform in comparison. In the broadband range, the slope steepened, and complexity decreased continuously from wakefulness to N3 sleep. REM sleep, however, was best discriminated by the narrowband slope. Importantly, slope and complexity also differed between tasks during wakefulness. While narrowband complexity decreased with task engagement, the slope flattened in both frequency ranges. Interestingly, only the narrowband slope was positively correlated with task performance. Our results show that slope and complexity are sensitive indices of brain state variations during wakefulness and sleep. However, the spectral slope yields more information and could be used for a greater variety of research questions than Lempel-Ziv complexity, especially when a narrowband frequency range is used.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10978822 | PMC |
http://dx.doi.org/10.1523/ENEURO.0259-23.2024 | DOI Listing |
J Voice
September 2025
Department of Communication Sciences and Disorders, University of Iowa, Iowa City, IA.
Background: Strained voice quality-commonly referred to as vocal strain-is a hallmark of functional voice disorders such as muscle tension dysphonia and is often associated with vocal fatigue and laryngeal hyperfunction. Although listeners describe it as excessive vocal effort, strained voice quality frequently overlaps perceptually with breathiness and roughness, complicating reliable assessment. Despite its clinical relevance, no standardized acoustic definition of strained voice quality has been established.
View Article and Find Full Text PDFAnal Chim Acta
October 2025
State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, 030006, China; Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, 030006, China.
Background: In coal quality analysis, spectroscopic techniques such as near-infrared spectroscopy (NIRS) and X-ray fluorescence (XRF) offer rapid and non-destructive measurements, but differences between instruments and coal types may lead to the failure of established models. Given the complexity of coal, it is important to systematically evaluate the applicability of traditional calibration transfer methods, such as the Slope/Bias (S/B) method and Piecewise Direct Standardization (PDS). Meanwhile, machine learning algorithm such as Domain-Adversarial Neural Networks (DANN), have shown great potential in addressing data distribution differences between source and target domains, offering new possibilities for calibration transfer.
View Article and Find Full Text PDFJ Acoust Soc Am
September 2025
Department of Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania 15213, USA.
Surficial sediments are highly susceptible to physical, biological, and chemical processes, which can create significant heterogeneity, affecting the transmission and scattering of elastic waves. Non-invasive medical shear wave elastography (SWE) can potentially resolve shear speed heterogeneity in this delicate surficial layer. Samples were extracted from two mudflats in New Hampshire, USA, where sound speed and attenuation were measured 1 cm below the water-sediment interface using the core and resonance logger (200 kHz-1 MHz).
View Article and Find Full Text PDFLin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi
September 2025
To explore the value of spectral CT parameters combined with dynamic contrast enhanced magnetic resonance imaging(DCE-MRI) parameters in the short-term efficacy of concurrent chemoradiotherapy for nasopharyngeal carcinoma. A total of 110 cases with nasopharyngeal carcinoma Ⅲ-Ⅳ staging who received synchronous radiotherapy and chemotherapy at our Hospital from October 2022 to October 2024 were regarded as the study subjects. Complying with the evaluation results after radiotherapy and chemotherapy, they were divided into a complete remission(CR) group of 53 cases and a non CR group of 57 cases.
View Article and Find Full Text PDFSci Rep
September 2025
Department of Photonics, College of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan.
This paper characterizes the performance of 940 nm single-junction (1 J) and triple-junction (3 J) vertical-cavity surface-emitting laser (VCSEL) arrays, tested at room temperature under 1.8 ns pulsed current injection. By suppressing thermal effects, the slope efficiency (SE) of the 1 J VCSEL array reaches 1.
View Article and Find Full Text PDF