Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: The aim of the study was to define a core outcome set (COS) to be measured following cataract surgery for the postoperative evaluation of monofocal intraocular lenses (IOLs). Compared to current COSs, the present work provides updates considering the advances in the technology due to the development of new generation monofocal IOLs, which are characterized by a safety profile comparable to standard monofocal IOLs but with an extended range of intermediate vision.

Methods: Healthcare professionals (ophthalmologist surgeons) and patients were involved in the selection of outcomes to be included in the COS, starting from a list of indicators retrieved from a systematic literature search. The search considered observational studies with both a retrospective or prospective design, case studies and classic randomized controlled trials (RCTs). A mixed methodology integrating a Delphi-driven and an expert panel approach was adopted to reach an agreement among clinicians, while patients were involved in the completion of a questionnaire.

Results: The final COS included 15 outcomes. Eleven outcomes, all clinical, were considered for inclusion after a joint discussion among ophthalmologists; seven outcomes were linked to visual acuity, while the remaining to contrast sensitivity, refractive errors, aberrations and adverse events. Measurement metrics, method of aggregation and measurement time point of these outcomes were specified. The most important aspects for the patients were (1) quality of life after cataract surgery, (2) the capacity to perform activities requiring good near vision (e.g., reading), (3) spectacle independence, and (4) safety of movements without fear of getting hurt or falling (intermediate vision).

Discussion: In a context with limited healthcare resources, it is important to optimize their use considering also the preferences of end-users, namely patients. The proposed COS, developed involving both ophthalmologists and patients, provides an instrument for the postoperative evaluation of different technologies in the context of monofocal IOLs, which can be used not only in clinical trials but also in clinical practice to increase the body of real-world evidence.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10912568PMC
http://dx.doi.org/10.3389/fmed.2024.1339793DOI Listing

Publication Analysis

Top Keywords

cataract surgery
12
monofocal iols
12
core outcome
8
outcome set
8
monofocal intraocular
8
intraocular lenses
8
postoperative evaluation
8
patients involved
8
monofocal
5
patients
5

Similar Publications

Purpose: To evaluate the time required for refractive error (RE) stabilization after standard phacoemulsification cataract surgery and identify preoperative factors influencing this duration.

Methods: This prospective case series study enrolled patients who had undergone phacoemulsification cataract surgery. RE stabilization was defined as 0.

View Article and Find Full Text PDF

Incision capsular bag herniation during subluxated lens surgery: mechanisms, management, and prevention.

Front Med (Lausanne)

August 2025

Eye Center, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China.

Purpose: To investigate the mechanism, intraoperative characteristics, management, and prevention of incision capsular bag herniation (ICBH), a previously unreported complication during cataract surgery in eyes with lens subluxation.

Methods: A retrospective observational case series was conducted on five male patients who developed ICBH during phacoemulsification with intraocular lens (IOL) implantation between January 2019 and December 2024. Among 867 subluxated-lens surgeries performed during this period, the estimated incidence of ICBH was 0.

View Article and Find Full Text PDF

Purpose: To report clinical outcomes in patients implanted with an isofocal optic-design intraocular lens (IOL) with double C-loop haptics following cataract surgery.

Methods: This was a multicentre-prospective-study involving 108 eyes (54 subjects) implanted with the Isopure Serenity (BVI, Inc). IOL.

View Article and Find Full Text PDF

ObjectivePseudoexfoliation syndrome is a systemic disease of unknown etiology, seen in advanced ages, characterized by extracellular material accumulation in ocular tissues and visceral organs. Autophagy, which is a basic metabolic pathway, provides macromolecule recycling of the cell and maintains cell homeostasis by adapting to the cell's stress environment. The aim of this study was to examine the relationship between specific mechanisms of autophagy and pseudoexfoliation syndrome.

View Article and Find Full Text PDF

PurposeTo evaluate the safety and ability of an ophthalmic solution containing Poloxamer 407 and Polyquaternium 133 to reduce conjunctival bacterial load before cataract surgery.MethodsPatients (n = 74) were randomized to 2 groups: treatment (n = 37) or placebo (treatment's vehicle; (n = 37)) BID from V1 to V3. Patients were also given standard postoperative treatment from V2 to V3.

View Article and Find Full Text PDF