98%
921
2 minutes
20
Obtaining the complex refractive index vectors (~) and (~) allows calculation of the (infrared) reflectance spectrum that is obtained from a solid in any of its many morphological forms. We report an adaptation to the KBr pellet technique using two gravimetric dilutions to derive quantitative (~)/(~) for dozens of powders with greater repeatability. The optical constants of bisphenol A and sucrose are compared to those derived by other methods, particularly for powdered materials. The variability of the values for bisphenol A was examined by 10 individual measurements, showing an average coefficient of variation for peak heights of 5.6%. Though no established standards exist, the pellet-derived peak values of bisphenol A differ by 11% and 31% from their single-angle- and ellipsometry-derived values, respectively. These values provide an initial estimate of the precision and accuracy of complex refractive indices that can be derived using this method. Limitations and advantages of the method are discussed, the salient advantage being a more rapid method to derive / for those species that do not readily form crystals or specular pellets.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.514661 | DOI Listing |
Clin Ophthalmol
September 2025
Alaska Blind Child Discovery, Alaska Children's EYE & Strabismus, Anchorage, Alaska, 99508, USA.
Background: Portable sphero-cylinder refraction is useful for remote medical missions and self-checking. A novel, inexpensive, handheld optical scope with an internal vision chart and adjustable diopter lens, called the Moptim MRT-200, was therefore validated.
Methods: Young, capable patients from a pediatric eye practice had dry refraction estimates with the Moptim MRT-200, Adaptica 2WIN photoscreener, and Monocular Retinomax compared with actual refined retinoscopy.
J Refract Surg
September 2025
From National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.
Purpose: To use parametric numerical simulation to characterize and compare the differences in corneal biomechanical responses to laser in situ keratomileusis (LASIK) and keratorefractive lenticule extraction (KLEx) under various surgical settings.
Methods: The Finite Element Model was used in a parametric study to evaluate corneal biomechanical responses to LASIK and KLEx, considering variations in preoperative corneal thickness, corneal flap/cap thickness and diameter, refractive correction, and optical zone diameter. Surgery-induced stress, displacement, and interface contact pressure were compared between LASIK and KLEx using the Wilcoxon signed-rank test.
Curr Opin Ophthalmol
September 2025
Singapore Eye Research Institute, Singapore National Eye Centre.
Purpose Of Review: Modern presbyopia-correcting intraocular lenses (IOLs) offer a potential solution to address the rising postoperative demand and expectations for spectacle independence following cataract surgery. However, IOL calculation and selection becomes more complex when presented with previous corneal refractive surgery (CRS) or co-existing corneal conditions. This review explores the use of presbyopia-correcting IOLs in eyes with co-existing corneal conditions or surgically altered corneas.
View Article and Find Full Text PDFVestn Oftalmol
September 2025
Krasnov Research Institute of Eye Diseases, Moscow, Russia.
Modern surgical strategies for keratoconus aim to both stabilize disease progression and correct induced refractive errors. Effectively and simultaneously achieving both goals remains a relevant challenge. This study presents a clinical case of femtosecond laser-assisted intrastromal keratoplasty with implantation of a biosynthetic complex, demonstrating the efficacy of this surgical approach in treating keratoconus.
View Article and Find Full Text PDFTransl Vis Sci Technol
September 2025
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, People's Republic of China.
Purpose: The purpose of this study was to estimate the correlations between macular optical coherence tomography (OCT)-derived metrics and incident glaucoma risk in myopic eyes.
Methods: This longitudinal observational study included 24,181 individuals with myopia (spherical equivalence [SE] ≤ -0.5 diopters [D]) from the UK Biobank study.