Correlation of Ocular Biometry with Axial Length in Elderly Japanese.

Clin Ophthalmol

Department of Ophthalmology, Saitama Medical Center, Saitama Medical University, Kawagoe-shi, Saitama, Japan.

Published: February 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Ocular parameters are not only useful for diagnosing diseases but also for guiding treatment approaches. A lot of previous studies have reported ocular parameters and its relations before cataract surgery. However, despite ethnic differences in ocular biometry, few reports have dealt with Japanese. Hence, this retrospective cross-sectional study aimed to measure parameters of preoperative cataract patients and examines the correlations between each parameter in Japanese elderly people.

Patients And Methods: The 210 subjects had their ocular axial lengths measured with OA-2000. The endpoints were ocular axial length (AL), central corneal thickness (CCT), average anterior corneal radius of curvature (CR), white-to-white (WTW), anterior chamber depth (ACD), and lens thickness (LT). Our analyses utilized the eye with the longer AL in each person. Each parameter was analyzed for correlations in a round-robin manner. Regression analyses were performed on parameters correlated with AL.

Results: The parameters correlated with AL were CR (r = 0.33, P < 0.0001), WTW (r = 0.29, P < 0.0001), ACD (r = 0.59, P < 0.0001), and LT (r = -0.30, P < 0.0001). These parameters related to AL in all simple regression equations (CR (P < 0.0001), WTW (P = 0.0002), ACD (P < 0.0001), LT (P = 0.0001)). In multiple regression analyses, CR, ACD, and LT might relate to AL (CR (P = 0.0002), ACD (P < 0.0001), LT (P = 0.018)). LT tended to be thinner as AL increased, while CR, WTW, and ACD tended to increase.

Conclusion: This information may be useful in developing strategies for ophthalmic surgery, as it provides information on the location of intraocular tissues. Various parameters have been used in intraocular lens (IOL) power calculations in recent years and knowledge of the interrelationship among parameters may be useful in determining IOL power according to ethnicity in the future.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10850987PMC
http://dx.doi.org/10.2147/OPTH.S446031DOI Listing

Publication Analysis

Top Keywords

ocular biometry
8
axial length
8
parameters
8
ocular parameters
8
ocular axial
8
regression analyses
8
parameters correlated
8
00001
8
00001 wtw
8
00002 acd
8

Similar Publications

Purpose: To evaluate intraocular lens (IOL) power calculation of a non-diffractive extended depth of focus (EDOF) IOL after myopic laser in situ keratomileusis (LASIK) without historical data.

Methods: In this consecutive case series, patients who had undergone lens surgery with implantation of a non-diffractive EDOF IOL after myopic laser in situ keratomileusis (LASIK) at the Department of Ophthalmology, University Hospital Frankfurt, Frankfurt, Germany, were included. Preoperative assessments included biometry and tomography using Scheimpflug technology (Pentacam; Oculus Optikgeräte GmbH).

View Article and Find Full Text PDF

Purpose: To determine the accuracy of a new machine learning-based open-source IOL formula (PEARLS-DGS) in 100 patients who underwent uncomplicated cataract surgery and had a history of laser refractive surgery for myopic defects.

Methods: The setting for this retrospective study was HUMANITAS Research Hospital, Milan, Italy. Data from 100 patients with a history of photorefractive keratectomy or laser in situ keratomileusis were retrospectively analyzed to assess the accuracy of the formula.

View Article and Find Full Text PDF

Purpose: To assess differences in intraocular lens (IOL) power calculation prediction error (PE) considering the manufacturing tolerance or exact power (EP) versus labeled power (LP), and to compare accuracy using the Barrett formula with optimized constant versus a thick-lens formula.

Methods: The PE and absolute PE were calculated for a random eye of patients implanted with the multifocal Liberty Q-Flex 640PM IOL (Medicontur Ltd) considering the LP and the EP provided by the manufacturer. The outcomes for the Barrett with optimized constant formula and a thick-lens formula personalized for the surgeon, biometer, and IOL were compared.

View Article and Find Full Text PDF

Purpose: To compare refractive prediction accuracy using simulated keratometry (SimK) measurements obtained from a Scheimpflug tomographer (Pentacam AXL, Oculus) versus keratometry (K) measurements obtained from an optical biometer utilizing telecentric keratometry (IOLMaster 700 (IOLM700), Carl Zeiss Meditec AG) applied to modern IOL power calculation formulas.

Design: Retrospective accuracy and validity analysis METHODS: Setting: Private practice center STUDY POPULATION: Five hundred eighty-nine eyes with preoperative SimK and K measurements undergoing phacoemulsification and implantation of monofocal IOL (Clareon SY60WF IOL, Alcon Laboratories, Inc.).

View Article and Find Full Text PDF

Purpose: This study reports the changes in aqueous humor dynamics (AHD) and biometric parameters associated with growth and maturation in male Dutch-belted rabbits.

Methods: In this prospective observational study, 20 male Dutch-belted rabbits were studied at 4-weekly intervals starting at 10 weeks through 38 weeks of age. Data collected included intraocular pressure (IOP), aqueous flow, outflow facility by tonography and fluorophotometry (acetazolamide method), episcleral venomanometry, central corneal thickness, corneal diameter, anterior chamber depth, and testicular volume.

View Article and Find Full Text PDF