Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Eyewitness testimony serves as important evidence in the legal system. Eyewitnesses of a crime can be either the victims themselves-for whom the experience is highly self-referential-or can be bystanders who witness and thus encode the crime in relation to others. There is a gap in past research investigating whether processing information in relation to oneself versus others would later impact people's suggestibility to misleading information. In two experiments (Ns = 68 and 122) with Dutch and Chinese samples, we assessed whether self-reference of a crime event (i.e., victim vs. bystander) affected their susceptibility to false memory creation. Using a misinformation procedure, we photoshopped half of the participants' photographs into a crime slideshow so that they saw themselves as victims of a nonviolent crime, while others watched the slideshow as mock bystander witnesses. In both experiments, participants displayed a self-enhanced suggestibility effect: Participants who viewed themselves as victims created more false memories after receiving misinformation than those who witnessed the same crime as bystanders. These findings suggest that self-reference might constitute a hitherto new risk factor in the formation of false memories when evaluating eyewitness memory reports.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bsl.2644DOI Listing

Publication Analysis

Top Keywords

susceptibility false
8
false memory
8
false memories
8
crime
6
self-relevance enhances
4
enhances susceptibility
4
false
4
memory eyewitness
4
eyewitness testimony
4
testimony serves
4

Similar Publications

Background: This study evaluated the applicability of histopathology, culture, and Metagenomic next-generation sequencing (mNGS) in diagnosing periprosthetic joint infection (PJI).

Methods: In this prospective trial, 215 consecutive patients with suspected knee PJI were enrolled. Tissue specimens were aseptically collected and processed for histopathological analysis, culture, and mNGS.

View Article and Find Full Text PDF

Pyrazinamide (PZA) plays a crucial role in the treatment of both active and latent tuberculosis, particularly in regimens designed to treat drug-resistant TB. However, diagnosing resistance to PZA poses challenges for managing TB, highlighting the need for accurate detection methods. This study aims to address the challenges in detecting PZA resistance by modifying the standard MGIT960 PZA drug susceptibility testing method by optimizing the inoculum dilution.

View Article and Find Full Text PDF

Background And Objectives: The β-lactam/β-lactamase inhibitor combinations ampicillin-sulbactam (SAM) and amoxicillin-clavulanate (AMC) are frequently used to treat Enterobacterales infections and are often assumed to be interchangeable, leading some clinical microbiology laboratories to report antimicrobial susceptibility testing (AST) results for only one of these agents. Given differences in β-lactamase inhibition between sulbactam and clavulanate, we hypothesized that the activities of SAM and AMC may differ.

Methods: To understand the prevalence of discordant SAM and AMC susceptibility results in Enterobacterales species, we analysed AST results obtained by broth microdilution (MicroScan WalkAway, Beckman Coulter) for Enterobacterales isolates recovered from clinical specimens between 2018 and 2022 at an academic medical centre in New York City.

View Article and Find Full Text PDF

Subcellular distribution-based reference-free cancer cell discrimination with a novel AIE cationic probe.

Anal Chim Acta

November 2025

College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China. Electronic address:

Background: The development of specific fluorescent probes for cancer cell discrimination holds significant promise for advancing cancer diagnostics. Conventionally, these probes operate by translating differences in biomarkers or microenvironmental factors into variations in whole-cell fluorescence intensity. However, this dominant, intensity-based strategy is highly susceptible to extraneous fluctuations arising from probe concentration, illumination instability and complex intracellular environment.

View Article and Find Full Text PDF

Over 60 % of kidney transplant candidates are non-sensitised while remaining 40 % are sensitised because of previous exposure to human alloantigens during previous transplants, blood transfusions, and pregnancy in women. Pre-transplant compatibility testing is mandatory prior to renal transplantation for detecting the presence of donor-specific antibodies (DSAs), which are associated with early hyperacute/acute and later chronic rejections. Initially, complement-dependent cytotoxicity crossmatch (CDCXM) was used as a traditional method for detecting preformed DSAs.

View Article and Find Full Text PDF