A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A novel microfluidic chip-based digital PCR method for enhanced sensitivity in the early diagnosis of colorectal cancer via mSEPT9. | LitMetric

A novel microfluidic chip-based digital PCR method for enhanced sensitivity in the early diagnosis of colorectal cancer via mSEPT9.

Clin Chim Acta

Department of Laboratory Medicine, Fujian Key Laboratory of Laboratory Medicine, Gene Diagnosis Research Center, Fujian Clinical Research Center for Laboratory Medicine of Immunology, The First Affiliated Hospital, Fujian Medical University, Fuzhou 350005, Fujian, China; Department of Laboratory Med

Published: February 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: To enhance the sensitivity of plasma methylated Septin9 gene (mSEPT9) detection in colorectal cancer (CRC) screening, we developed a microfluidic chip-based digital PCR (dPCR) method suitable for low-concentration samples, aiming to apply it for mSEPT9 detection in CRC diagnosis.

Methods: Our microfluidic chip-based dPCR method utilized specific primers and probes with locked nucleic acids (LNAs) modifications for mSEPT9 detection. We evaluated its performance, including detection limit, specificity, and linear range, comparing it with a commercial qPCR reagent kit using the same samples (95 CRC, 23 non-CRC).

Results: The LNAs-modified dPCR method showed a linear range of 10-10 copies/μL and a detection limit of 10 copies/μL. Clinical testing revealed that our dPCR method exhibited a sensitivity of 82.11 % and specificity of 95.65 % for CRC diagnosis, outperforming the commercial qPCR kit (sensitivity: 58.95 %, specificity: 91.30 %), particularly in Stage I with a diagnostic sensitivity of 90.91 %. Combining mSEPT9 and carcinoembryonic antigen (CEA) improved diagnostic sensitivity to 91.49 %.

Conclusions: Our accurate microfluidic chip-based dPCR method, especially in combination with CEA, holds promise for effective CRC screening and timely interventions, offering enhanced mSEPT9 quantification over conventional qPCR.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cca.2024.117781DOI Listing

Publication Analysis

Top Keywords

dpcr method
20
microfluidic chip-based
16
msept9 detection
12
chip-based digital
8
digital pcr
8
colorectal cancer
8
crc screening
8
chip-based dpcr
8
detection limit
8
linear range
8

Similar Publications