A portable low-cost device to quantify advective gas fluxes from mofettes into the lower atmosphere: First application to Starzach mofettes (Germany).

Environ Monit Assess

Center for Applied Geoscience, University of Tübingen, Schnarrenbergstr. 94-96, Tübingen, 72076, Baden-Württemberg, Germany.

Published: January 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this study, we introduce a portable low-cost device for in situ gas emission measurement from focused point sources of CO, such as mofettes. We assess the individual sensors' precision with calibration experiments and perform an independent verification of the system's ability to measure gas flow rates in the range of liters per second. The results from one week of continuous CO flow observation from a wet mofette at the Starzach site is presented and correlated with the ambient meteorological dynamics. In the observed period, the gas flow rate of the examined mofette exhibits a dominant cycle of around four seconds that is linked to the gas rising upwards through a water column. We find the examined mofette to have a daily emission of 465 kg ±16 %. Furthermore, two events were observed that increased the flow rate abruptly by around 25 % within only a few minutes and a decaying period of 24 hours. These types of events were previously observed by others at the same site but dismissed as measurement errors. We discuss these events as a hydrogeological phenomenon similar to cold-water geyser eruptions. For meteorological events like the passages of high pressure fronts with steep changes in atmospheric pressure, we do not see a significant correlation between atmospheric parameters and the rate of gas exhalation in our one-week time frame, suggesting that on short timescales the atmospheric pumping effect plays a minor role for wet mofettes at the Starzach site.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10781820PMC
http://dx.doi.org/10.1007/s10661-023-12114-8DOI Listing

Publication Analysis

Top Keywords

portable low-cost
8
low-cost device
8
gas flow
8
starzach site
8
flow rate
8
examined mofette
8
events observed
8
gas
6
device quantify
4
quantify advective
4

Similar Publications

Construction of an Ag-functionalized structural color hydrogel sensor for colorimetric detection of glutathione.

Mikrochim Acta

September 2025

Hunan Key Laboratory of Typical Environmental Pollution and Health Hazards, School of Public Health, Hengyang Medical School, University of South China, Hengyang, 421001, China.

An Ag-functionalized structural color hydrogel (Ag-SCH) sensor is constructed for colorimetric detection of glutathione (GSH). The hydrogel is prepared by using the coordination of Ag and 1-vinylimidazole (1-VI) as cross-linking network. GSH acts as a competitive ligand to break the coordination between Ag and 1-VI, leading to the expansion and structural color change of the hydrogel.

View Article and Find Full Text PDF

Transposing intensive care innovation from modern warfare to other resource-limited settings.

Eur J Trauma Emerg Surg

September 2025

French Military Medical Service Academy - École du Val-de-Grâce, Paris, France.

Background: Delivering intensive care in conflict zones and other resource-limited settings presents unique clinical, logistical, and ethical challenges. These contexts, characterized by disrupted infrastructure, limited personnel, and prolonged field care, require adapted strategies to ensure critical care delivery under resource-limited settings.

Objective: This scoping review aims to identify and characterize medical innovations developed or implemented in recent conflicts that may be relevant and transposable to intensive care units operating in other resource-limited settings.

View Article and Find Full Text PDF

An electrochemiluminescence device powered by streaming potential for the detection of amines in flowing solution.

Nat Commun

September 2025

Department of Chemical Science and Engineering, School of Materials and Chemical Technology, Institute of Science Tokyo, Nagatsuta-cho, Midori-ku, Yokohama, Japan.

The research and implementation of portable and low-cost analytical devices that possess high reproducibility and ease of operation is still a challenging task, and a growing field of importance, within the analytical research. Herein, we report the concept, design and optimization of a microfluidic device based on electrochemiluminescence (ECL) detection that can be potentially operated without electricity for analytical purposes. The device functions exploiting the concept of streaming potential-driven bipolar electrochemistry, where a potential difference, generated from the flow of an electrolyte through a microchannel under the influence of a pressure gradient, is the driving force for redox reactions.

View Article and Find Full Text PDF

This study explores deep feature representations from photoplethysmography (PPG) signals for coronary artery disease (CAD) identification in 80 participants (40 with CAD). Finger PPG signals were processed using multilayer perceptron (MLP) and convolutional neural network (CNN) autoencoders, with performance assessed via 5-fold cross-validation. The CNN autoencoder model achieved the best results (recall 96.

View Article and Find Full Text PDF

Research advances in SERS-based sensing platforms for multiplex mycotoxin detection in feed.

Nanoscale Adv

September 2025

State Key Laboratory of Animal Nutrition and Feeding, Institute of Animal Science, Chinese Academy of Agricultural Sciences Beijing 100193 China

Mycotoxins in feed can pose significant risks to the health of livestock and poultry, leading to reduced economic returns and impaired production efficiency, thereby impeding the sustainable development of the livestock industry. Consequently, the exploration of highly sensitive, simple and rapid detection methods for trace mycotoxins in feed is crucial for ensuring feed safety and promoting industrial sustainability. Surface-enhanced Raman spectroscopy (SERS), a rapid detection method characterized by high sensitivity, ease of operation, and resistance to water interference, has gained substantial traction in mycotoxin detection within feed matrices in recent years.

View Article and Find Full Text PDF