98%
921
2 minutes
20
Screening for high-risk human papillomavirus (HPV) infection is one of the most important preventative measures for cervical cancer. However, fast, convenient, and low-cost HPV detection remains challenging, especially in resource-limited settings. Here, we report a portable all-in-one device (PAD) for point-of-care testing (POCT) for HPV16 and HPV18 DNA in cervical swabs. The PAD was engineered to integrate modules for extraction-free sample lysis, loop-mediated isothermal amplification (LAMP) with lyophilized reagent beads, and real-time colorimetric signal sensing into a single miniaturized device, considerably shortening the sample-to-result time to 15 min. The precision liquid handling in the completely sealed microfluidic chip is achieved by a uniquely designed pressure-balanced automatic liquid flow mechanism, thereby eliminating the need for manual manipulation of liquids and thus the risk of biohazards. The PAD employs an improved real-time colorimetric LAMP (rcLAMP) assay with a limit of detection (LOD) of 1 copy/μL, enabled by enhanced assay chemistry to maximize the reaction kinetics. To validate this device for clinical application, we tested 206 clinical cervical swab samples and obtained a sensitivity of 92.1% and a specificity of 99.0%. This custom PAD enabled by microfluidic and electronic engineering techniques can be configured for the simultaneous detection of HPV16 and HPV18 or other pathogens in point-of-care applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2023.115968 | DOI Listing |
Chemistry
September 2025
Institute for Advanced Study, Shenzhen University, Shenzhen, 518060, P. R. China.
The long-term visualization of intracellular Fe dynamics and lysosomal activity is crucial for investigating the physiological roles and functions of lysosomes during the growth of organisms. The lysosome-targeted fluorescent probe (RBH-EdC), derived from rhodamine-nucleoside conjugates, demonstrates a sophisticated dual-activation design: one is Fe⁺ response, triggering spirolactam ring-opening to form xanthine structures, resulting in ≥ 1000-fold fluorescence enhancement with visible colorimetric transition (colorless→pink). Another is pH sensitivity, demonstrating protonation-dependent fluorescence amplification at the dC at site N3 (pK= 2.
View Article and Find Full Text PDFMikrochim Acta
September 2025
Department of Analytical Chemistry, China Pharmaceutical University, 24 TongJiaXiang, Nanjing, 210009, Jiangsu, China.
A nanozyme-mediated cascade reaction system for fluorometric and colorimetric dual-mode detection of sarcosine (SA) was developed. The nanozymes (Zn-Glu@Hemin) were synthesized via a rapid self-assembly within 10 min at room temperature. Importantly, the Zn-Glu@Hemin exhibited strong peroxidase (POD)-mimicking activity, catalyzing the generation of hydroxyl radical (·OH) and superoxide anion (O) from hydrogen peroxide (HO), enhancing the fluorescence reaction of o-phenylenediamine (OPD) and the colorimetric reaction of 3,3',5,5'-tetramethylbenzidine (TMB).
View Article and Find Full Text PDFPLoS One
September 2025
Department of Zoology, Baba Guru Nanak University, Nankana Sahib, Pakistan.
Secreted frizzled-related protein 4 (sFRP4) plays a fundamental role in the regulation of Wnt signalling, which is crucial for cellular proliferation and differentiation. The sFRP4 has garnered significant interest as a therapeutic target for metabolic diseases and cancer due to its mechanism of action. Although existing sFRP4 modulators show limited specificity and notable off-target effects, our study explores the potential of known bioactive compounds as more selective and less toxic alternatives.
View Article and Find Full Text PDFACS Appl Mater Interfaces
September 2025
Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand.
Strain sensors have received considerable attention in personal healthcare due to their ability to monitor real-time human movement. However, the lack of chemical sensing capabilities in existing strain sensors limits their utility for continuous biometric monitoring. Although the development of dual wearable sensors capable of simultaneously monitoring human motion and biometric data presents significant challenges, the ability to fabricate these sensors with geometries tailored to individual users is highly desirable.
View Article and Find Full Text PDFACS Omega
September 2025
Department of Chemistry, Materials and Chemical Engineering "G. Natta", Politecnico di Milano, Via Mancinelli 7, Milan 20131 Italy.
Point-of-Care (PoC) diagnostics are transforming healthcare by enabling rapid and accessible disease detection right at the patient's bedside. This comprehensive review examines recent advances in nucleic acid (NA)-based PoC testing, revealing how these technologies are revolutionizing molecular diagnostics. Here, we critically analyze the three key components of NA-based PoC development: (i) probe design strategies, (ii) immobilization techniques, and (iii) detection methodologies.
View Article and Find Full Text PDF