Article Abstract

To evaluate the feasibility of cryoballoon (CB) ablation of atrial fibrillation (AF) under the guidance of a new three-dimensional (3D) mapping system KODEX-EPD. 40 patients scheduled for CB ablation of AF in the first affiliated Hospital of Xinjiang Medical University from August 2021 to July 2022 were randomly divided into two groups: KODEX-EPD 3D mapping system guidance group (KODEX group, n = 20) and conventional two-dimensional perspective group (standard group, n = 20). The ablation time, operation time, fluoroscopy time, fluoroscopy dose, contrast agent dosage and follow-up data were compared between the two groups. Besides, the feasibility and accuracy of the dielectric sensing system in evaluating pulmonary vein (PV) occlusion in patients with AF during CB ablation were verified. All pulmonary veins were being isolated. The ablation time (36.40 ± 6.72 min vs 35.15 ± 6.29 min, P > 0.05) and the operation time (64.20 ± 11.82 min vs 66.00 ± 13.18 min, P > 0.05) were not statistically different in the two groups. The standard group has longer fluoroscopy time, dose and contrast medium dosage. There were significant differences in fluoroscopy time (532.30 ± 72.83 s vs 676.25 ± 269.33 s, P < 0.05), fluoroscopy dose (110.00 ± 28.64 mGy vs 144.68 ± 66.66 mGy, P < 0.05), and contrast medium dosage (71.90 ± 5.97 ml vs 76.05 ± 5.93 ml, P < 0.05) between the two groups. The learning curves of the first 5 patients and the last 15 patients in the KODEX group were compared. There was no statistical difference in the ablation time (36.80 ± 8.56 min vs 36.27 ± 6.34 min, P > 0.05) or the operation time (69.00 ± 5.00 min vs 62.60 ± 13.10 min, P > 0.05); however, compared to the first 5 patients, fluoroscopy time (587.40 ± 38.34 s vs 513.93 ± 73.02 s, P < 0.05), fluoroscopy dose (147.85 ± 35.19 mGy vs 97.39 ± 8.80 mGy, P < 0.05) and contrast medium dosage (79.60 ± 1.14 ml vs 69.33 ± 4.45 ml, P < 0.05) were significantly decreased. Using pulmonary venography as the gold standard, the sensitivity, specificity of the completely occlusion in KODEX group was 93.6% (95% CI 85-97.6%) and 69.6% (95% CI 54-81.8%); and the sensitivity, specificity of the small leak in KODEX group was 93.1% (95% CI 82.4-97.8%) and 82.0% (95% CI 65.9-91.9%). During an average follow-up of (9.90 ± 1.06) months, there was no statistical difference in arrhythmia recurrence and antiarrhythmic drugs taking after CB ablation between the two groups (P > 0.05). Using the KODEX-EPD system, the CB ablation procedure can correctly evaluate the PV occlusion, and significantly reduce fluoroscopy exposure and contrast medium without significantly increasing the operation time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10746707PMC
http://dx.doi.org/10.1038/s41598-023-49475-6DOI Listing

Publication Analysis

Top Keywords

fluoroscopy time
12
cryoballoon ablation
8
ablation atrial
8
atrial fibrillation
8
mapping system
8
group n = 20
8
standard group
8
ablation time
8
operation time
8
time fluoroscopy
8

Similar Publications

Objective: To quantify C-arm-registered radiation exposure during ultrasound- and fluoroscopy-guided spinal interventional pain management in dogs, and to measure operator-based radiation levels to identify discrepancies between delivered and received dose.

Study Design: A retrospective observational study.

Animals: A total of 82 canine spinal interventional pain management procedures performed at a single referral institution.

View Article and Find Full Text PDF

Beyond the Learning Curve: How Operator Experience Affects Pulsed-Field Ablation Outcomes.

Heart Rhythm

September 2025

Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland. Electronic address:

Background: The learning curve for pulmonary vein isolation (PVI) using "single-shot" pulsed-field ablation (PFA) is thought to be short. 3D electro-anatomical mapping (3D-EAM) might provide adjunctive information to shorten the learning curve and improve lesion durability.

Objective: To analyze procedural performance markers over time for PVI using PFA and 3D-EAM.

View Article and Find Full Text PDF

DesignRandomized Controlled Trial.ObjectivePostoperative pain after lumbar spine surgery remains a clinical challenge. Fluoroscopy-guided erector spinae plane block (ESPB) has been proposed as a feasible technique for reducing pain and opioid use, particularly when ultrasound guidance is not available.

View Article and Find Full Text PDF

A Fluoroless Workflow Using Transoesophageal Echocardiography for Catheter Ablation of Atrial Fibrillation Using Pulsed Field Ablation.

Heart Lung Circ

September 2025

Cardiology Department, Westmead Hospital, Sydney, NSW, Australia; Westmead Applied Research Centre, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia. Electronic address:

Background: Catheter ablations are increasingly performed with zero or minimal fluoroscopy, enabled by ultrasound imaging and electro-anatomical mapping. Pulsed field ablation (PFA) using Farawave has been dependent on fluoroscopic assessment of catheter conformation and contact. We aimed to demonstrate the feasibility of a PFA workflow for pulmonary vein isolation (PVI) and extrapulmonary ablation.

View Article and Find Full Text PDF

Objectives: As a two-dimensional modality, venography has limitations in its capacity to measure lumen caliber and to assess stenotic disease accurately. This has implications in the management of end-stage renal-disease (ESRD) patients "no-option" candidates access for arteriovenous fistula (AVF) or graft (AVG) creation secondary to high risk of vascular access failure. The incremental diagnostic and clinical impact of intravascular ultrasound (IVUS) was quantified in this tunneled dialysis catheter dependent ESRD cohort.

View Article and Find Full Text PDF