Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Camonsertib is a highly selective and potent inhibitor of ataxia telangiectasia and Rad3-related (ATR) kinase. Dose-dependent anemia is a class-related on-target adverse event often requiring dose modifications. Individual patient risk factors for the development of significant anemia complicate the selection of a "one-size-fits-all" ATR inhibitor (ATRi) dose and schedule, possibly leading to suboptimal therapeutic doses in patients at low risk of anemia. We evaluated whether early predictors of anemia could be identified to ultimately inform a personalized dose-modification approach.

Patients And Methods: On the basis of preclinical observations and a mechanistic understanding of ATRi-related anemia, we identified several potential factors to explore in a multivariable linear regression modeling tool for predicting hemoglobin level ahead of day 22 (cycle 2) of treatment.

Results: In patients treated with camonsertib monotherapy (NCT04497116), we observed that hemoglobin decline is consistently preceded by reticulocytopenia, and dose- and exposure-dependent decreases in monocytes. We developed a nomogram incorporating baseline and day 8 hemoglobin and reticulocyte values that predicted the day 22 hemoglobin values of patients with clinically valuable concordance (within 7.5% of observations) 80% of the time in a cross-validation performance test of data from 60 patients.

Conclusions: The prediction of future hemoglobin decrease, after a week of treatment, may enable a personalized, early dose modification to prevent development of clinically significant anemia and resulting unscheduled dose holds or transfusions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10870112PMC
http://dx.doi.org/10.1158/1078-0432.CCR-23-2080DOI Listing

Publication Analysis

Top Keywords

patients treated
8
ataxia telangiectasia
8
telangiectasia rad3-related
8
anemia identified
8
day hemoglobin
8
anemia
7
hemoglobin
5
development practical
4
practical nomogram
4
nomogram personalized
4

Similar Publications

Management of Transvenous Leads in Patients With Iatrogenic Lead Perforation.

J Cardiovasc Electrophysiol

September 2025

Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.

Introduction: Iatrogenic lead perforation is a rare but serious complication of cardiac implantable electronic device (CIED) implantation. Evidence on percutaneous management of subacute or delayed cases remains limited.

Methods: We retrospectively reviewed 38 patients treated for iatrogenic lead perforation between January 2012 and October 2024.

View Article and Find Full Text PDF

Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.

View Article and Find Full Text PDF

Background: The treatment of critically ill patients in intensive care units is becoming increasingly complex. For example, organ transplants are regularly carried out, the recipients are seriously ill, and the postoperative course can be complicated. This is why organ replacement and hemadsorption procedures are becoming increasingly important.

View Article and Find Full Text PDF

Background: The treatment of mandibular angle fractures remains controversial, particularly regarding the method of fixation. The primary aim of this study was to compare surgical outcomes following treatment with 1-plate versus 2-plate fixation across two oral and maxillofacial surgery clinics. The secondary aim was to evaluate associations between patient-, trauma-, and procedure-specific factors with postoperative complications and to identify high-risk patients for secondary osteosynthesis.

View Article and Find Full Text PDF

Identifying levels of alcohol use disorder severity in electronic health records.

Subst Abuse Treat Prev Policy

September 2025

Centre for Interdisciplinary Addiction Research (ZIS), Department of Psychiatry and Psychotherapy, University Medical Center Hamburg-Eppendorf (UKE), Martinistraße 52, 20246, Hamburg, Germany.

Background: Alcohol use disorder (AUD) is conceptualized as a dimensional phenomenon in the DSM-5, but electronic health records (EHRs) rely on binary AUD definitions according to the ICD-10. The present study classifies AUD severity levels using EHR data and tests whether increasing AUD severity levels are linked with increased comorbidity.

Methods: Billing data from two German statutory health insurance companies in Hamburg included n = 21,954 adults diagnosed with alcohol-specific conditions between 2017 and 2021.

View Article and Find Full Text PDF