Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Over the last years, inverse gas chromatography (IGC) proved to be a versatile and sensitive analytical technique for physicochemical properties. However, the comparability of results obtained by different users and devices remains a topic for debate. This is the first time, an interlaboratory study using different types of IGC instruments is reported. Eight organizations with different IGC devices defined a common lab measurement protocol to analyse two standard materials, silica and lactose. All data was collected in a standard result form and has been treated identically with the objective to identify experimentally observed differences and not potentially different data treatments. The calculated values of the dispersive surface energy vary quite significantly (silica: 22 mJ/m - 34 mJ/m, lactose 37 mJ/m - 51 mJ/m) and so do the ISP values and retention volumes for both materials. This points towards significant and seemingly undiscovered differences in the operation of the instruments and the obtained underlying primary data, even under the premise of standard conditions. Variations are independent of the instrument type and uncertainties in flow rates or the injected quantities of probe molecules may be potential factors for the differences. This interlaboratory study demonstrates that the IGC is a very sensitive analytical tool, which detects minor changes, but it also shows that for a proper comparison, the measurement conditions have to be checked with great care. A publicly available standard protocol and material, for which this study can be seen as a starting point, is still needed to judge on the measurements and the resulting parameters more objectively.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2023.464526DOI Listing

Publication Analysis

Top Keywords

interlaboratory study
12
inverse gas
8
gas chromatography
8
sensitive analytical
8
mj/m mj/m
8
reproducibility inverse
4
chromatography infinite
4
infinite dilution
4
dilution interpretations
4
interpretations interlaboratory
4

Similar Publications

Breaking the reproducibility barrier with standardized protocols for plant-microbiome research.

PLoS Biol

September 2025

Environmental Genomics and Systems Biology, Lawrence Berkeley National Laboratory, Berkeley, California, United States of America.

Inter-laboratory replicability is crucial yet challenging in microbiome research. Leveraging microbiomes to promote soil health and plant growth requires understanding underlying molecular mechanisms using reproducible experimental systems. In a global collaborative effort involving five laboratories, we aimed to help advance reproducibility in microbiome studies by testing our ability to replicate synthetic community assembly experiments.

View Article and Find Full Text PDF

Conventional one-dimensional gas chromatography methods for gasoline quality monitoring require separate analyses for different component classes, limiting analytical efficiency and unconventional additive detection. This study presents a comprehensive two-dimensional gas chromatography with flame ionization detection (GC × GC-FID) platform enabling simultaneous quantification of regulated components and rapid screening of unconventional additives in a single analytical run. The method achieved excellent agreement with ASTM standards and high repeatability for BTEX (benzene, toluene, ethylbenzene, and xylenes) and oxygenates in gasoline.

View Article and Find Full Text PDF

Introduction: Discrepancies in factor IX activity (FIX:C) measurements between one-stage clotting assays (OSAs) have been observed following infusion with recombinant factor IX extended half-life concentrates (EHL-rFIX) in the treatment of haemophilia B. These variations, primarily due to differences in activated partial thromboplastin time (APTT) reagents, complicate clinical decision-making.

Objectives: The aim of this study was to evaluate whether drug-specific calibrations for albumin-fused recombinant FIX (rFIX-FP) and Fc-fused recombinant FIX (rFIX-Fc) could reduce inter-reagent discrepancies.

View Article and Find Full Text PDF

Ki67 is a broadly available biomarker of proliferation with various approaches to its evaluation in breast cancer. The International Ki67 in Breast Cancer Working Group (IKWG) recommends calculating Ki67 globally across the tumor area, as this method offers high interobserver concordance. These recommendations have been integrated into many international breast cancer guidelines (ASCO, ESMO), yet there is no real-world data on if it improved inter-pathologists and inter-laboratory variability.

View Article and Find Full Text PDF

Digital PCR (dPCR) technology is widely utilized for various applications, including the quantification of gene mutations and copy number variations. Certified reference materials (CRMs) play a critical role in improving the comparability of dPCR results, establishing SI-traceable copy number concentration values for dPCR calibration remains a key challenge due to the limited availability of CRMs value-assigned by higher-order, independent methods. To tackle this issue, a linearized plasmid DNA reference material (RM) was developed and rigorously characterized through an interlaboratory comparison involving three national measurement institutes (NMIs) from China (NIM), South Korea (KRISS), and Japan (NMIJ).

View Article and Find Full Text PDF