Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Indoor pollutants have been associated with worse clinical outcomes in chronic obstructive pulmonary disease (COPD). Elevated biomarkers are associated with ambient pollution exposure, however the association with indoor pollution remains unclear.

Methods: Former smokers with spirometry-confirmed COPD were randomized to portable air cleaner or placebo. Indoor particulate matter (PM, PM, and ultrafine particles [UFP; PM]) and biomarkers were measured longitudinally at pre-specified intervals and course PM fraction (PM) was calculated. Biomarkers were categorized based on associations with biologic mechanisms: inflammation (white blood cell count, interleukin [IL]-6, IL-8, IL-1β, tumor necrosis factor-α, interferon-γ, serum amyloid A), platelet activation (P-selectin, CD40 ligand [CD40L], 11-dehdydro-thromboxane-B2 [11dTxB2]), endothelial dysfunction (Vascular Cell Adhesion Molecule [VCAM]-1, Intercellular Adhesion Molecule [ICAM]-1), and oxidative stress (thiobarbituric acid reactive substances [TBARS], 8-hydroxydeoxyguanosine, 8-isoprostane). Associations between PM concentrations and each biomarker were analyzed using multivariable linear mixed models. An intention-to-treat analysis was performed to evaluate the air cleaner intervention on the biomarker levels longitudinally.

Results: Fifty-eight participants were randomized to each group. Finer PM was more strongly associated with higher IL-8 (mean difference per doubling: UFP 13.9% [p = 0.02], PM 6.8% [p = 0.002], PM 5.0% [p = 0.02]) while interferon-γ was associated with UFP and IL-1β with PM. UFP and PM were associated with elevated levels of the oxidative stress biomarkers TBARS and 8-isoprostane respectively. For platelet activation markers, UFP was associated with higher 11dTxB2 while PM was associated with higher P-selectin and CD40L. Pollutants were not associated with biomarkers of endothelial dysfunction. In intention-to-treat analysis there was no association of the air cleaner intervention with any of the biomarkers.

Discussion: Among former smokers with COPD, elevated levels of indoor air pollutants, particularly ultrafine particles (PM), were associated with elevated biomarkers of inflammation, platelet activation, and oxidative stress. However, an air cleaner intervention that reduced PM did not significantly reduce biomarker levels.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10872275PMC
http://dx.doi.org/10.1016/j.envres.2023.117874DOI Listing

Publication Analysis

Top Keywords

air cleaner
20
cleaner intervention
16
platelet activation
12
oxidative stress
12
associated higher
12
associated
9
indoor particulate
8
particulate matter
8
smokers copd
8
pollutants associated
8

Similar Publications

CFD Evaluation of Far-UVCand Air Cleaning Technologies in Classrooms without Mechanical Ventilation.

J Hazard Mater

September 2025

Architectural Engineering Department, Pennsylvania State University, University Park, PA, USA. Electronic address:

Far-UVC systems and air cleaners are effective strategies for controlling airborne pathogen transmission, particularly in densely occupied spaces with insufficient ventilation, such as school classrooms. This study evaluates the disinfection performance and ozone (O) formation of different far-UVC systems and air cleaners in a standard-sized classroom using computational fluid dynamics (CFD) simulation. Results show that ceiling-mounted far-UVC systems reduce airborne pathogen exposure by up to 30 % more than upper-room and wall-mounted configurations, based on intake fractions and room-average concentrations.

View Article and Find Full Text PDF

Mapping street-level air pollution: One year of mobile monitoring in disadvantaged communities across New York State.

J Air Waste Manag Assoc

September 2025

New York State Department of Environmental Conservation, Division of Air Resources, Albany, NY, USA.

New York State has enacted public policies that have enabled a multi-decadal trend in air quality improvement. However, the benefits of cleaner air are not felt equally across the populace, with individuals residing in disadvantaged communities bearing disproportionate air pollution burdens due to proximity of polluting sources, in addition to other environmental stressors. To address this disparity, the New York State Department of Environmental Conservation contracted with Aclima, Inc.

View Article and Find Full Text PDF

Background: Particulate matter with an aerodynamic diameter of ≤2.5 µm (PM) is a heterogeneous mixture, and specific substances that affect cardiovascular events remain unknown. We aimed to examine the association of short-term exposure to PM and its components with hospital admissions for acute myocardial infarction (AMI).

View Article and Find Full Text PDF

With growing concerns over fossil fuel depletion, environmental pollution, and the need for sustainable energy solutions, alternative renewable fuels have gained significant attention in the transportation sector. Biodiesel and ethanol are promising biofuels that can reduce dependence on conventional diesel and lower harmful emissions. However, challenges such as fuel compatibility and combustion inefficiencies limit their widespread adoption in compression ignition engines.

View Article and Find Full Text PDF

Background: Black carbon is a critical component of ambient particulate matter and a recognized trigger of respiratory morbidity. Although existing studies have explored the link between black carbon exposure and pediatric asthma, evidence specific to rapidly industrializing middle-income regions remains scarce. In Thailand, increasing industrial activities, agricultural burning, and vehicle emissions have resulted in higher black carbon concentrations; however, comprehensive epidemiological data on the impact of this on children with asthma exacerbations remain limited.

View Article and Find Full Text PDF