98%
921
2 minutes
20
Aim And Objective: The objective of this study was to optimize the threshold for discrete cosine transform (DCT) coefficients for near-lossless compression of Tc-99 m Dimercaptosuccinic acid (DMSA) scan images using discrete cosine transformation.
Materials And Methods: Two nuclear medicine (NM) Physicians after reviewing several Tc-99 m DMSA scan images provided 242 Tc-99 m DMSA scan images that had scar. These Digital imaging and communication in medicine (DICOM) images were converted in the Portable Network Graphics (PNG) format. DCT was applied on these PNG images, which resulted in DCT coefficients corresponding to each pixel of the image. Four different thresholds equal to 5, 10, 15, and 20 were applied and then inverse discrete cosine transformation was applied to get the compressed Tc-99 m DMSA scan images. Compression factor was calculated as the ratio of the number of nonzero elements after thresholding DCT coefficients to the number of nonzero elements before thresholding DCT coefficients. Two NM physicians who had provided the input images visually compared the compressed images with its input image, and categorized the compressed images as either acceptable or unacceptable. The quality of compressed images was also assessed objectively using the following eight image quality metrics: perception-based image quality evaluator, structural similarity index measure (SSIM), multiSSIM, feature similarity indexing method, blur, global contrast factor, contrast per pixel, and brightness. Pairwise Wilcoxon signed-rank sum tests were applied to find the statistically significant difference between the value of image quality metrics of the compressed images obtained at different thresholds and the value of the image quality metrics of its input images at the level of significance = 0.05.
Results: At threshold 5, (1) all compressed images (242 out of 242 Tc-99 m DMSA scan images) were acceptable to both the NM Physicians, (2) Compressed image looks identical to its original image and no loss of clinical details was noticed in compressed images, (3) Up to 96.65% compression (average compression: 82.92%) was observed, and (4) Result of objective assessment supported the visual assessment. The quality of compressed images at thresholds 10, 15, and 20 was significantly better than that of input images at < 0.0001. However, the number of unacceptable compressed images at thresholds 10, 15, and 20 was 6, 38, and 70, respectively.
Conclusions: Up to 96.65%, near-losses compression of Tc-99 m DMSA images was found using DCT by thresholding DCT coefficients at a threshold value equal to 5.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10693356 | PMC |
http://dx.doi.org/10.4103/ijnm.ijnm_136_22 | DOI Listing |
Environ Sci Pollut Res Int
September 2025
Vellore Institute of Technology, Vellore, 632014, Tamil Nadu, India.
The significant global energy consumption strongly emphasizes the crucial role of net-zero or green structures in ensuring a sustainable future. Considering this aspect, incorporating thermal insulation materials into building components is a well-accepted method that helps to enhance thermal comfort in buildings. Furthermore, integrating architectural components made from solid refuse materials retrieved from the environment can have significant environmental benefits.
View Article and Find Full Text PDFCureus
August 2025
Internal Medicine, University of California Los Angeles, Los Angeles, USA.
This report discusses a case of a 33-year-old healthy woman who presented with upper extremity swelling and pain, which she attributed to an injury sustained during her work as a professional dancer. Given her persistent symptoms, she was eventually referred to the emergency room for evaluation of possible thrombosis. She was found to have an elevated D-dimer, and a CT angiogram of the chest revealed narrowing of the bilateral subclavian veins suggestive of venous thoracic outlet syndrome (VTOS).
View Article and Find Full Text PDFCureus
August 2025
Investigation, Hospital Regional de Alta Especialidad de Ixtapaluca, Mexico City, MEX.
Splenic pseudocysts represent an uncommon condition in abdominal surgery, generally resulting from trauma, infection, or ischemic processes. Histologically, they are characterized by the absence of an epithelial lining; that is, they lack the inner layer of cells typically found in true cysts. Its clinical presentation is non-specific, commonly manifesting with abdominal pain, early satiety, or alterations in bowel habits, which lead to late or incidental diagnoses through imaging studies.
View Article and Find Full Text PDFCureus
August 2025
General Medicine, Sri Ramachandra Institute of Higher Education and Research, Chennai, IND.
Ankylosing spondylitis (AS) is a chronic inflammatory spondyloarthropathy that predominantly affects the axial skeleton. While hallmark features such as sacroiliitis and syndesmophytes are well recognized, the presence of mediastinal masses may pose a diagnostic dilemma and raise concerns for malignancy or atypical infection. We report a middle-aged man in the fifth decade of life with longstanding untreated AS presenting with progressive quadriparesis.
View Article and Find Full Text PDFVet Surg
September 2025
Clinic for Small Animals, University of Veterinary Medicine Hannover, Hannover, Germany.
Objective: To describe and compare arthroscopy-assisted (AA) with fluoroscopy-assisted (FA) minimally invasive plate osteosynthesis (MIPO) for simple transverse acetabular fractures.
Study Design: Ex vivo cadaveric study.
Sample Population: A total of 10 canine cadavers (>20 kg) without coxofemoral joint disease.