Lu-177-PSMA dosimetry for kidneys and tumors based on SPECT images at two imaging time points.

Front Med (Lausanne)

Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China.

Published: November 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Personalized dosimetry for Lu-177-PSMA treatment requires multiple-time-point SPECT/CT scans to calculate time-integrated activity (TIA). This study evaluates two-time-point (TTP) methods for TIA calculation for kidneys and tumors.

Methods: A total of 18 patients treated with 3.7-7.4 GBq Lu-177 PSMA-617 were analyzed retrospectively, including 18 sets of left and right kidneys, as well as 45 tumors. Four quantitative SPECT/CT (4TP) were acquired at 2 h, 20 h, 40 h, 60 h ( = 11), or 200 h ( = 7) after treatment, and they were fit bi-exponentially as reference. The TTP method was fitted by a mono-exponential washout function using two selected imaging time points for kidneys. For tumors, one uptake and one washout phase were modeled, assuming linear (type I) and same (type II) uptake phase between 0 h to the first time point and mono-exponential washout thereafter. Two single-time-point (STP) methods were also implemented for comparison. TIA calculated by TTP and STP methods were compared with reference to the 4TP TIA.

Results: For the kidneys, the TTP methods using 20 h-60 h and 40 h-200 h had smaller mean absolute errors of 8.05 ± 6.05% and 4.95 ± 3.98%, respectively, as compared to other combinations of time points and STP methods. For tumors, the type I and type II TTP methods using 20h-60 h and 40-200 h had smaller mean absolute errors of 6.14 ± 5.19% and 12.22 ± 4.44%, and 8.31 ± 7.16% and 4.48 ± 7.10%, respectively, as compared to other TTP and STP methods.

Conclusion: The TTP methods based on later imaging time demonstrated fewer errors than the STP methods in kidney and tumor TIA. Imaging at 20 h-60 h and 40 h-200 h could simplify the dosimetry procedures with fewer TIA estimation errors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10679348PMC
http://dx.doi.org/10.3389/fmed.2023.1246881DOI Listing

Publication Analysis

Top Keywords

ttp methods
16
stp methods
16
imaging time
12
time points
12
kidneys tumors
8
methods
8
mono-exponential washout
8
type type
8
ttp stp
8
h-60 h-200
8

Similar Publications

Objectives: We assessed time to provider (TTP) for patients with a non-English language preference (NELP) compared to patients with an English language preference (ELP) in the emergency department (ED).

Methods: We conducted a retrospective cohort study of adults presenting between 2019 and 2023 to a large urban ED. We used a 2-step classification that first identified NELP from patients' reported language at registration, followed by identification in the narrative text of the triage note.

View Article and Find Full Text PDF

Acute kidney injury (AKI) is a common clinical syndrome characterized by abnormal renal function and structure. Microcirculatory perfusion disorders and inflammatory responses are critical pathophysiologies of AKI. Recently, ultrasound molecular imaging has been considered a valuable tool for preclinical and clinical diagnostics that can sensitively target histological structures of interest, particularly in evaluating renal microcirculation.

View Article and Find Full Text PDF

Impact of Risk Factors and a New Transfer Pathway on Endovascular Thrombectomy Outcomes in Acute Ischemic Stroke.

World Neurosurg

September 2025

Departments of Neurology; Department of Biological Science; Doctoral Program of Clinical and Experimental Medicine, College of Medicine, National Sun Yat-Sen University, Kaohsiung, Taiwan; Department of Neurology, Xiamen Chang Gung Memorial Hospital, Xiamen, Fujian, China. Electronic address: chlu99

Objective: Endovascular thrombectomy (EVT) is a time-critical therapy for acute ischemic stroke (AIS) caused by large vessel occlusion. To improve transfer efficiency, a web-based EVT transfer system was implemented in the Taiwan Stroke Network. This study evaluated its impact on workflow metrics and patient outcomes.

View Article and Find Full Text PDF

Background: The shape of the continuous wave Doppler (CWD) envelope in functional tricuspid valve regurgitation (fTR) results from the dynamic interplay between flow, pressure gradient and impedance. Although the v-wave cut-off shape in fTR is a well-recognized feature of severe TR, the complete spectrum of TR CWD shapes across the different fTR severity ranges has not been thoroughly explored, which is the scope of the present study.

Methods: In 245 patients with fTR, TR was graded with transthoracic echocardiography using the corrected proximal isovelocity surface area method and CWD shapes were scored, both qualitatively (using visual scoring into parabolic, triangular or v-wave cut-off categories) and quantitatively using a novel Vmax/Vmean parameter and time-to-peak velocity corrected for TR duration (TTP/TRD).

View Article and Find Full Text PDF

The associations between female fecundability and postpartum breastfeeding: A prospective cohort study.

PLoS One

September 2025

Key Laboratory of Environmental Medicine and Engineering of Ministry of Education, Department of Epidemiology and Health Statistics, School of Public Health, Southeast University, Nanjing, Jiangsu, China.

Objective: This study aimed to investigate the relationship between women's fecundability and postpartum breastfeeding.

Methods: We used a prospective cohort study design to recruit pregnant women who came to the hospital for antenatal checkups before 20 weeks' gestation between April 2019 and March 2020 at the Maternal and Child Health Hospital of Gulou District, Nanjing, China. Women were categorized into prolonged time to pregnancy (TTP) group (>3 months) and shorten TTP (≤3 months) groups.

View Article and Find Full Text PDF