A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A ratiometric fluorescence imprinted sensor based on N-CDs and metal-organic frameworks for visual smart detection of malathion. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Sensitive and rapid detection of pesticide residues in food is essential for human safety. A ratiometric imprinted fluorescence sensor N-CDs@Eu-MOF@MIP (BR@MIP) was constructed to sensitively detect malathion (Mal). Europium-based metal organic frameworks (Eu-MOF) were used as supporters to improve the sensitivity of the BR@MIP. N-doped carbon dots (N-CDs) were used as fluorescent source to produce fluorescent signal. A linear relationship between the concentration of Mal and the fluorescence response of the sensor was found in the Mal concentration range of 1-10 μM with a limit of detection (LOD) of 0.05 μM. Furthermore, the sensor was successfully applied for the detection of Mal in lettuce, tap water, and soil samples, with recoveries in the range of 93.0 % - 99.3 %. Additionally, smartphone-based sensors were used to detect Mal in simulated real samples. Thus, the construction of ratiometric imprinted fluorescence sensor has provided a good strategy for the detection of Mal.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2023.138068DOI Listing

Publication Analysis

Top Keywords

ratiometric imprinted
8
imprinted fluorescence
8
fluorescence sensor
8
detection mal
8
mal
6
sensor
5
detection
5
ratiometric fluorescence
4
fluorescence imprinted
4
imprinted sensor
4

Similar Publications