Background: Maximum diameter measurements are used to assess the rupture risk of abdominal aortic aneurysms (AAAs); however, these are not precise enough to predict all ruptures. Four-dimensional (4D) flow MRI-derived parameters provide additional information by visualizing hemodynamics in AAAs but merit further investigation before they are clinically applicable.
Purpose: To assess the reproducibility of 4D flow MRI-derived hemodynamics, to investigate possible correlations with lumen and maximum diameter, and to explore potential relationships with vorticity and aneurysm growth.
Study Type: Prospective single-arm study.
Population: A total of 22 (71.5 ± 6.1 years, 20 male) asymptomatic AAA patients with a maximum diameter of at least 30 mm.
Field Strength/sequence: A 3.0 T/Free-breathing 4D flow MRI phase-contrast acquisition with retrospective ECG-gating.
Assessment: Patients underwent two consecutive 4D flow MRI scans 1-week apart. Aortic volumes were segmented from time-averaged phase contrast magnetic resonance angiographies. Reproducibility was assessed by voxelwise analysis after registration. Mean flow velocity, mean wall shear stress (WSS), mean lumen diameter, and qualitative vorticity scores were assessed. In addition, Dixon MRI and retrospective surveillance data were used to study maximum diameter (including thrombus), intraluminal thrombus volume (ILT), and growth rate.
Statistical Tests: For reproducibility assessment, Bland-Altman analyses, Pearson correlation, Spearman's correlation, and orthogonal regression were conducted. Potential correlations between hemodynamics and vorticity scores were assessed using linear regression. P < 0.05 was considered statistically significant.
Results: Test-retest median Pearson correlation coefficients for flow velocity and WSS were 0.85 (IQR = 0.08) m/sec and 0.82 (IQR = 0.10) Pa, respectively. Mean WSS significantly correlated with mean flow velocity (R = 0.75) and inversely correlated with mean lumen diameter (R = -0.73). No significant associations were found between 4D flow MRI-derived hemodynamic parameters and maximum diameter (flow velocity: P = 0.98, WSS: P = 0.22).
Data Conclusion: A 4D flow MRI is robust for assessing the hemodynamics within AAAs. No correlations were found between hemodynamic parameters and maximum diameter, ILT volume and growth rate.
Level Of Evidence: 2 TECHNICAL EFFICACY: Stage 2.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jmri.29138 | DOI Listing |
Eur J Nucl Med Mol Imaging
September 2025
Department of Nuclear Medicine, Changhai Hospital, Naval Medical University, 168 Changhai Road, Yang Pu District, Shanghai, 200433, China.
Purpose: In this retrospective study, whether [Ga]Ga-DOTA-FAPI-04 PET/MR imaging biomarkers can predict the progression-free survival (PFS) and overall survival (OS) of patients with advanced pancreatic cancer was investigated.
Methods: Fifty-one patients who underwent [Ga]Ga-DOTA-FAPI-04 PET/MR scans before first-line chemotherapy were recruited. Imaging biomarkers, including the maximum tumor diameter, minimum apparent diffusion coefficient (ADC), maximum and mean standardized uptake values (SUV and SUV), fibroblast activation protein- (FAP-) positive tumor volume (FTV and W-FTV) and total lesion FAP expression (TLF and W-TLF), were recorded for primary and whole-body tumors.
Arch Esp Urol
August 2025
Department of Urology, The Affiliated Hospital of Qingdao University, 266000 Qingdao, Shandong, China.
Background: Ureteroscopic lithotripsy using a semi-rigid ureteroscope is the standard treatment for urinary stones. Doxazosin-an alpha-1 adrenergic receptor blocker-relaxes ureteral smooth muscles, reducing peristalsis and contraction frequency. This study aimed to evaluate the efficacy and safety of adjunctive doxazosin before semi-rigid ureteroscopy and retrograde intrarenal surgery (RIRS) for urinary stones.
View Article and Find Full Text PDFSurg Endosc
September 2025
Department of Surgery and Oncology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Background: Laparoscopic donor nephrectomy requires precise renal artery management for optimal outcomes. This study evaluates the performance and safety of automatic staplers in dividing renal arteries of various diameters.
Methods: Experimental tests were conducted using porcine arteries (3, 5, and 7 mm) to compare double- and triple-row staplers in terms of stapling completeness and pressure resistance.
Zhonghua Bing Li Xue Za Zhi
September 2025
Department of Pathology, the Affiliated Hospital of Qingdao University, Qingdao 266000, China.
To investigate the clinicopathological characteristics of well-differentiated papillary mesothelial tumor (WDPMT). Sixteen cases of resected WDPMTs diagnosed at the Affiliated Hospital of Qingdao University, Qingdao, China from 2017 to 2024 were collected and the clinicopathological features were retrospectively analyzed. There were 7 males amd 9 females, with a mean age of 53.
View Article and Find Full Text PDFZhonghua Bing Li Xue Za Zhi
September 2025
Department of Pathology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200025, China.
To investigate the clinicopathological and genetic characteristics of monomorphic epitheliotropic intestinal T-cell lymphoma (MEITL). The forty-two MEITL cases diagnosed in the Department of Pathology, Ruijin Hospital affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China from 2016 to 2022 was retrospectively analyzed. Clinical data were collected, and follow-up was performed.
View Article and Find Full Text PDF