A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A segmentation model to detect cevical lesions based on machine learning of colposcopic images. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Semantic segmentation is crucial in medical image diagnosis. Traditional deep convolutional neural networks excel in image classification and object detection but fall short in segmentation tasks. Enhancing the accuracy and efficiency of detecting high-level cervical lesions and invasive cancer poses a primary challenge in segmentation model development.

Methods: Between 2018 and 2022, we retrospectively studied a total of 777 patients, comprising 339 patients with high-level cervical lesions and 313 patients with microinvasive or invasive cervical cancer. Overall, 1554 colposcopic images were put into the DeepLabv3+ model for learning. Accuracy, Precision, Specificity, and mIoU were employed to evaluate the performance of the model in the prediction of cervical high-level lesions and cancer.

Results: Experiments showed that our segmentation model had better diagnosis efficiency than colposcopic experts and other artificial intelligence models, and reached Accuracy of 93.29 %, Precision of 87.2 %, Specificity of 90.1 %, and mIoU of 80.27 %, respectively.

Conclution: The DeepLabv3+ model had good performance in the segmentation of cervical lesions in colposcopic post-acetic-acid images and can better assist colposcopists in improving the diagnosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10623278PMC
http://dx.doi.org/10.1016/j.heliyon.2023.e21043DOI Listing

Publication Analysis

Top Keywords

segmentation model
12
cervical lesions
12
colposcopic images
8
high-level cervical
8
deeplabv3+ model
8
segmentation
6
lesions
5
cervical
5
model
5
model detect
4

Similar Publications