Electrochemical analysis of total phospholipids in human serum for severe sepsis diagnosis.

Talanta

Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, South Korea. Electronic address:

Published: February 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Electrochemical analysis of total phospholipids was performed for the diagnosis of sepsis. The influence of electrode materials on the analysis of the chromogenic substrate was analyzed using Au, graphite, and pyrolyzed carbon electrodes. The total phospholipid analysis based on electrochemical analysis with pyrolyzed carbon was used for diagnosis of sepsis using sera from healthy volunteers, systemic inflammatory response syndrome (SIRS), and severe sepsis patients. The analysis results using the optical measurement and the electrochemical analysis were compared for the serum samples from sepsis patients and healthy controls. Additionally, the interference of human serum on the optical measurement and electrochemical analysis was estimated by signal-to-noise (S/N) calculation. The assay results of the levels of other biomarkers for sepsis (C-reactive protein and procalcitonin) and the total phospholipid levels obtained using the optical measurement and electrochemical analysis methods were statistically similar. Finally, the mortality of patients, indicated by the results of the total phospholipid assay performed using the electrochemical analysis of the patient samples collected daily (1, 3, and 7 day(s) after admission to hospital), was compared with the patient mortality assessed via conventional severity indexes, such as the SOFA and APACHE Ⅱ scores. The 28-day survival rate was estimated by Kaplan-Meier survival analysis based on the total phospholipid level of patient samples that were obtained after 1, 3, and 7 day(s) from hospital admission.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2023.125374DOI Listing

Publication Analysis

Top Keywords

electrochemical analysis
28
total phospholipid
16
optical measurement
12
measurement electrochemical
12
analysis
10
analysis total
8
total phospholipids
8
human serum
8
severe sepsis
8
diagnosis sepsis
8

Similar Publications

The pervasive concern regarding veterinary drug residues in food necessitates advanced detection solutions, particularly addressing limitations of conventional methods reliant on large-scale instrumentation that incur prolonged analysis duration, complex sample preparation, and lack of real-time on-site capability. A portable "single response-on" molecularly imprinted ratiometric fluorescent paper-based sensor was developed for quantifying fleroxacin (FLX) residues in animal-derived foods, wherein B, N-co-doped MXene quantum dot (B, N-MQD) was synthesized and combined with BCP-Eu as dual-emission fluorophores, while FLX- molecularly imprinted polymer (FLX-MIP) was engineered using functionalized Nano-SiO as the carrier. Concentration-dependent fluorescence enhancement at 574 nm was exhibited with invariant reference signal at 411 nm, achieving a 36-fold lower detection limit (0.

View Article and Find Full Text PDF

Recyclable Cu-Catalyzed -Methylation and C5-Methylthiomethylation of Isatins with DMSO.

J Org Chem

September 2025

Guangxi Key Laboratory of Electrochemical and Magneto-Chemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004, China.

An unprecedented recyclable system of copper-catalyzed C-C/N coupling of isatins and DMSO without any oxidant and acidic/basic additive has been unlocked. The -isatins occur tandem -methylation and C5-methylthiomethylation in order, while -substituted isatins proceed C5-methylthiomethylation only. DMSO serves as Me and MeSCH sources as well as the solvent.

View Article and Find Full Text PDF

Target-Triggered Self-Assembly of Peptides with Silver Nanoparticles for Electrochemical Biosensing.

Chemistry

September 2025

State Key Laboratory of Analytical Chemistry for Life Science, School of Life Sciences, Nanjing University, Nanjing, 210023, P. R. China.

Peptides have great potential in the design and fabrication of biosensors because of their high specificity, multifunctionality, and relatively low cost. In this paper, we report an electrochemical biosensor leveraging multifunctional peptides and silver nanoparticles for integrated target recognition, self-assembly, and signal output. As a proof of concept, we chose granzyme B (GrB) as a model target.

View Article and Find Full Text PDF

Naturally conductive protein nanowires have inspired efforts to engineer electrical conductivity into synthetic fibrous proteins for the development of bioelectronic materials and devices. A comprehensive analysis of charge transport in these systems requires a combination of various measurement methods, instruments and electrode designs. Measurements under direct current (DC) typically focus on charge transport without distinguishing between charged species, requiring alternating current (AC) and electrochemical methods to probe additional phenomena.

View Article and Find Full Text PDF

Synergistic t-to-π* Electron Transfer and Nanotube Engineering in Spinal Catalysts for Ultra-Efficient Chloride Evolution.

Angew Chem Int Ed Engl

September 2025

Key Laboratory of Eco-chemical Engineering, Ministry of Education, International Science and Technology Cooperation Base of Eco-chemical Engineering and Green Manufacturing, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, P. R. China.

Facing the massive energy consumption of over 200 TWh y of chlor-alkali industry, developing high-activity and durable non-precious CER (chlorine evolution reaction) catalysts is urgently needed to address the high overpotentials and suppress the dissolution high-valance metal species. Herein, a carbon quantum dots functionalized trimetallic Fe/Co/Ni spinel oxide nanotube architecture (FCNO@CQDs) is constructed, featuring t-to-π* π-backbonding for dramatically enhanced CER activity and stability. The reverse electron flow from Co d-obritals to the vacant CQDs' π* orbitals can upshift the d-band center for enhanced intermediate adsorption, while stabilizing high-valent Co centers via increased bond order.

View Article and Find Full Text PDF