98%
921
2 minutes
20
Accurate susceptibility result of temocillin (TMO) is important for treating infections caused by multidrug-resistant Enterobacterales. This multicenter study aimed to investigate the performance of routine temocillin testing assays against Enterobacterales challenging strains. Forty-seven selected clinical isolates were blindly analyzed by 12 Belgian laboratories using VITEK® 2 (n = 5) and BD Phoenix™ (n = 3) automated systems, ETEST® gradient strip (n = 3), and disk (3 brands) diffusion method (DD; n = 6) for temocillin susceptibility using standardized methodology. Results were interpreted using EUCAST 2023 criteria and compared to the broth microdilution (BMD; Sensititre™ panel) method used as gold standard. Methods' reproducibility was assessed by testing 3 reference strains in triplicate. A total of 702 organism-drug results were obtained against 33 TMO-susceptible and 14 TMO-resistant isolates. Excluding Proteae species (P. mirabilis and M. morganii), the essential agreement rates were excellent (91.5-100%) for all MIC-based methods. The highest category agreement was achieved by ETEST® (97.5%) followed by VITEK® 2 (93.2%), disk diffusion (91.6%), and BD Phoenix™ (88.5%). BD Phoenix™ and paper disk diffusion overcalled resistance (11.5% and 6.8% of major discrepancies, respectively), while ROSCO tablets diffusion and VITEK® 2 generated higher very major discrepancies (7.1% and 4.2% respectively). Inter-assay reproducibility was unsatisfactory using recommended E. coli ATCC 25922 strain but was excellent with E. coli ATCC 35218 and K. pneumoniae ATCC 700603 strains. This interlaboratory study suggests that routine testing methods provide accurate and reproducible TMO categorization results except for Proteae species.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10096-023-04681-y | DOI Listing |
J Chromatogr A
September 2025
Luoyang R&D Center of Technology, SINOPEC Engineering (Group) Co., Ltd, Luoyang 471003, China. Electronic address:
Conventional one-dimensional gas chromatography methods for gasoline quality monitoring require separate analyses for different component classes, limiting analytical efficiency and unconventional additive detection. This study presents a comprehensive two-dimensional gas chromatography with flame ionization detection (GC × GC-FID) platform enabling simultaneous quantification of regulated components and rapid screening of unconventional additives in a single analytical run. The method achieved excellent agreement with ASTM standards and high repeatability for BTEX (benzene, toluene, ethylbenzene, and xylenes) and oxygenates in gasoline.
View Article and Find Full Text PDFHaemophilia
September 2025
Service d'Hématologie Biologique et d'Hémostase clinique, Hospices Civils De Lyon, UR4609 Université Claude Bernard Lyon 1, Lyon, France.
Introduction: Discrepancies in factor IX activity (FIX:C) measurements between one-stage clotting assays (OSAs) have been observed following infusion with recombinant factor IX extended half-life concentrates (EHL-rFIX) in the treatment of haemophilia B. These variations, primarily due to differences in activated partial thromboplastin time (APTT) reagents, complicate clinical decision-making.
Objectives: The aim of this study was to evaluate whether drug-specific calibrations for albumin-fused recombinant FIX (rFIX-FP) and Fc-fused recombinant FIX (rFIX-Fc) could reduce inter-reagent discrepancies.
Breast Cancer Res
September 2025
Department of Oncology and Pathology, Karolinska Institutet, Stockholm, Sweden.
Ki67 is a broadly available biomarker of proliferation with various approaches to its evaluation in breast cancer. The International Ki67 in Breast Cancer Working Group (IKWG) recommends calculating Ki67 globally across the tumor area, as this method offers high interobserver concordance. These recommendations have been integrated into many international breast cancer guidelines (ASCO, ESMO), yet there is no real-world data on if it improved inter-pathologists and inter-laboratory variability.
View Article and Find Full Text PDFTalanta
August 2025
Center for Advanced Measurement Science, National Institute of Metrology, 18 Beisanhuan East Road, Beijing, 100013, PR China. Electronic address:
Digital PCR (dPCR) technology is widely utilized for various applications, including the quantification of gene mutations and copy number variations. Certified reference materials (CRMs) play a critical role in improving the comparability of dPCR results, establishing SI-traceable copy number concentration values for dPCR calibration remains a key challenge due to the limited availability of CRMs value-assigned by higher-order, independent methods. To tackle this issue, a linearized plasmid DNA reference material (RM) was developed and rigorously characterized through an interlaboratory comparison involving three national measurement institutes (NMIs) from China (NIM), South Korea (KRISS), and Japan (NMIJ).
View Article and Find Full Text PDFInt J Cosmet Sci
September 2025
SGS Proderm GmbH, Schenefeld/Hamburg, Germany.
Objective: The consortium ALT-SPF performed an international round robin test to characterize non-invasive methods as alternatives to the erythema-based testing of sun protection factor (SPF) according to ISO 24444:2019.
Methods: Hybrid diffuse reflectance spectroscopy (HDRS) based on a multi-lambda LED light source uses in vivo reflectance spectra on skin to determine sunscreens in vivo absorbance spectra, which are fused with respective in vitro absorbance spectra measured as thin films transmission as described in ISO 24443:2019. As a part of the ALT-SPF consortium initiative, a blinded study on 64 samples was performed in four European laboratories.