A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Feasibility of UTE-MRI-based radiomics model for prediction of histopathologic subtype of lung adenocarcinoma: in comparison with CT-based radiomics model. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: To assess the feasibility of the UTE-MRI radiomic model in predicting the micropapillary and/or solid (MP/S) patterns of surgically resected lung adenocarcinoma.

Materials And Methods: We prospectively enrolled 74 lesions from 71 patients who underwent UTE-MRI and CT before curative surgery for early lung adenocarcinoma. For conventional radiologic analysis, we analyzed the longest lesion diameter and lesion characteristics at both UTE-MRI and CT. Radiomic features were extracted from the volume of interest of the lesions and Rad-scores were generated using the least absolute shrinkage and selection operator with fivefold cross-validation. Six models were constructed by combining the conventional radiologic model, UTE-MRI Rad-score, and CT Rad-score. The areas under the curves (AUCs) of each model were compared using the DeLong method. Early recurrence after curative surgery was analyzed, and Kaplan-Meier survival analysis was performed.

Results: Twenty-four lesions were MP/S-positive, and 50 were MP/S-negative. The longitudinal size showed a small systematic difference between UTE-MRI and CT, with fair intermodality agreement of lesion characteristic (kappa = 0.535). The Rad-scores of the UTE-MRI and CT demonstrated AUCs of 0.84 and 0.841, respectively (p = 0.98). Among the six models, mixed conventional, UTE-MRI, and CT Rad-score model showed the highest diagnostic performance (AUC = 0.879). In the survival analysis, the high- and low-risk groups were successfully divided by the Rad-score in UTE-MRI (p = 0.01) and CT (p < 0.01).

Conclusion: UTE-MRI radiomic model predicting MP/S positivity is feasible compared with the CT radiomic model. Also, it was associated with early recurrence in the survival analysis.

Clinical Relevance Statement: A radiomic model utilizing UTE-MRI, which does not present a radiation hazard, was able to successfully predict the histopathologic subtype of lung adenocarcinoma, and it was associated with the patient's recurrence-free survival.

Key Points: • No studies have reported the ultrashort echo time (UTE)-MRI-based radiomic model for lung adenocarcinoma. • The UTE-MRI Rad-score showed comparable diagnostic performance with CT Rad-score for predicting micropapillary and/or solid histopathologic pattern. • UTE-MRI is feasible not only for conventional radiologic analysis, but also for radiomics analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-023-10302-1DOI Listing

Publication Analysis

Top Keywords

radiomics model
8
lung adenocarcinoma
8
ute-mri
8
ute-mri radiomic
8
curative surgery
8
conventional radiologic
8
ute-mri rad-score
8
survival analysis
8
model
6
feasibility ute-mri-based
4

Similar Publications