98%
921
2 minutes
20
Per- and polyfluoroalkyl substances (PFAS) are widespread, persistent environmental contaminants that have been linked to various health issues. Comprehensive PFAS analysis often relies on ultra-high-performance liquid chromatography coupled with high-resolution mass spectrometry (UHPLC HRMS) and molecular fragmentation (MS/MS). However, the selection and fragmentation of ions for MS/MS analysis using data-dependent analysis results in only the topmost abundant ions being selected. To overcome these limitations, All Ions fragmentation (AIF) can be used alongside data-dependent analysis. In AIF, ions across the entire / range are simultaneously fragmented; hence, precursor-fragment relationships are lost, leading to a high false positive rate. We introduce IonDecon, which filters All Ions data to only those fragments correlating with precursor ions. This software can be used to deconvolute any All Ions files and generates an open source DDA formatted file, which can be used in any downstream nontargeted analysis workflow. In a neat solution, annotation of PFAS standards using IonDecon and All Ions had the exact same false positive rate as when using DDA; this suggests accurate annotation using All Ions and IonDecon. Furthermore, deconvoluted All Ions spectra retained the most abundant peaks also observed in DDA, while filtering out much of the artifact peaks. In complex samples, incorporating AIF and IonDecon into workflows can enhance the MS/MS coverage of PFAS (more than tripling the number of annotations in domestic sewage). Deconvolution in complex samples of All Ions data using IonDecon did retain some false fragments (fragments not observed when using ion selection, which were not isotopes or multimers), and therefore DDA and intelligent acquisition methods should still be acquired when possible alongside All Ions to decrease the false positive rate. Increased coverage of PFAS can inform on the development of regulations to address the entire PFAS problem, including both legacy and newly discovered PFAS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/jasms.3c00244 | DOI Listing |
Anal Chem
September 2025
Department of Chemistry, The University of Akron, Akron, Ohio 44325, United States.
Tires are complex polymeric materials composed of rubber elastomers (both natural and synthetic), fillers, steel wire, textiles, and a range of antioxidant and curing systems. These constituents are distributed differently among the various tire parts, which are classified based on their function and proximity to the rim. This study presents a rapid and sensitive approach for the characterization of tire components using mild thermal desorption/pyrolysis (TDPy) coupled to direct analysis in real-time mass spectrometry (DART-MS).
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
September 2025
Chemistry Department, Indiana University, 800 E Kirkwood Ave, Bloomington, Indiana 47405.
In charge detection mass spectrometry (CD-MS) ions are trapped in an electrostatic linear ion trap (ELIT) where they oscillate back and forth through a conducting cylinder. The oscillating ions induce a periodic charge separation that is detected by a charge sensitive amplifier (CSA) connected to the cylinder. The resulting time domain signal is analyzed using short-time Fourier transforms to give the mass-to-charge ratio and charge for each ion, which are then multiplied to give the mass.
View Article and Find Full Text PDFJ Phys Chem A
September 2025
Department of Chemistry, University of Georgia, Athens, Georgia 30602, United States.
Ti(CH) complexes produced by laser vaporization in a supersonic expansion are investigated with mass spectrometry, infrared laser photodissociation spectroscopy, and UV laser photodissociation. The mass distributions of the cluster ions produced are found to vary significantly with the sample rod mounting configuration in the source. For infrared spectroscopy experiments, the so-called "offset" rod mounting produces colder conditions than the "cutaway" configuration, which allows tagging the ions with one or more argon atoms for the = 1 and 2 complexes.
View Article and Find Full Text PDFACS Synth Biol
September 2025
Engineering Research Center of Western Resource Innovation Medicine Green Manufacturing, Ministry of Education, School of Chemical Engineering, Northwest University, Xi'an 710127, China.
The environmental resistance exhibited by microorganisms is concerned with their ability to withstand and adapt to an array of detrimental environmental conditions, with their survival and reproductive success being threatened. Within the realm of biotechnology, which emphasizes stress resistance, a critical role in bacterial adaptive strategies to environmental fluctuations is assumed to be in the periplasmic space. An innovative methodology to augment bacterial tolerance to stress by employing a mucin-mimetic collagen analogue, designated as S1552 (which is secreted into the periplasmic compartment), is introduced by this investigation.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
September 2025
Soft Matter Sciences and Engineering, CNRS, École supérieure de Physique et de Chimie Industrielles de la Ville de Paris, Université Paris Sciences et Lettres, Sorbonne Université, Paris 75005, France.
The sliding motion of aqueous droplets on hydrophobic surfaces leads to charge separation at the trailing edge, with implications from triple-line friction to hydrovoltaic energy generation. Charges deposited on the solid surface have been attributed to ions or electrons ripped off from the liquid drop. However, the dynamics and exact physicochemical nature of these surface-trapped charges remains poorly explored.
View Article and Find Full Text PDF