Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Aims: The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD.
Methods And Results: Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521).
Conclusion: Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10507661 | PMC |
http://dx.doi.org/10.1093/europace/euad270 | DOI Listing |