Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Aim: To compare the design, metallurgy, and mechanical properties of four heat-treated reciprocating instruments coupled with the evaluation of the irrigation flow using an in silico model.

Methodology: New EdgeOne Fire Primary, Easy-File Flex Regular 25, WaveOne Gold Primary and Reciproc Blue R25 instruments (n = 124) were initially evaluated regarding their design through stereomicroscopy, scanning electron microscopy and 3D surface scanning. In addition, energy-dispersive X-ray spectroscopy was utilized to determine their elemental composition, and differential scanning calorimetry tests to evaluate their phase transformation temperatures. Their mechanical performance was further assessed through torsional and bending tests. Using scans obtained from a real tooth and the instruments, a computational fluid dynamics assessment was conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparation. Mood's median and One-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%).

Results: Reciproc Blue exhibited a superior number of blades (n = 8), whereas EdgeOne Fire had the highest overall volume (4.38 mm ) and surface area (32.32 mm ). At the 3-mm axial level, EdgeOne Fire displayed the lowest core diameter (0.13 mm), while Reciproc Blue had the highest (0.16 mm). All blades were symmetrical, and the tips of the instruments were non-active but differed from each other. The most irregular surfaces were observed in EdgeOne Fire and Easy-File Flex. All instruments were manufactured from nickel-titanium alloys and exhibited distinct phase transformation temperatures. WaveOne Gold and Reciproc Blue demonstrated the highest maximum torque values (1.87 and 1.62 N cm, respectively), while the lowest was observed on EdgeOne Fire (1.21 N cm) (p < .05). The most flexible (p < .05) were EdgeOne Fire (angle of rotation: 602.6°; maximum bending load: 251.4 g.f) and Reciproc Blue (533.2° and 235.6 g.f). There were no significant differences observed in the irrigation flow among the four domains generated by the tested instruments.

Conclusions: Despite observing variations in the design, phase transformation temperatures, and in the torsional and bending test outcomes among the four heat-treated reciprocating instruments, no significant differences were found in the irrigation flow pattern among the different groups in the simulated root canal preparations.

Download full-text PDF

Source
http://dx.doi.org/10.1111/iej.13971DOI Listing

Publication Analysis

Top Keywords

edgeone fire
20
reciproc blue
16
irrigation flow
12
heat-treated reciprocating
8
reciprocating instruments
8
design metallurgy
8
metallurgy mechanical
8
mechanical performance
8
easy-file flex
8
waveone gold
8

Similar Publications

Aim: To comprehensively compare 12 nickel-titanium (NiTi) reciprocating single-file systems from eight manufacturers by integrating geometric, mechanical, metallurgical and in silico analyses.

Methodology: A total of 276 NiTi reciprocating instruments, representing 12 types across 8 brands, were selected, including Easy-File Flex Regular 25, EdgeOne Fire Primary, Flash 25.06vt, One Files R25 and Blue R25, One RECI N25, Perfect RC R25 (Blue, Gold and Silver), Reciproc R25 (Blue and M-Wire) and WaveOne Gold Primary.

View Article and Find Full Text PDF

Background: The goal of root canal preparation is to eliminate microorganisms and debris from the root canal system, while providing space for the placement of root filling materials. However, the process can lead to the formation of dentin microcracks, increasing the risk of vertical root fractures. This study used micro-CT to evaluate the formation of dentinal microcracks following instrumentation with One Curve, EdgeOne Fire, and VDW.

View Article and Find Full Text PDF

This study assessed the surface topography and plastic deformation (PD) of new and used contemporary reciprocating instruments. Twenty-six WaveOne Gold (WOG) and EdgeOne Fire (EO) instruments were photographed under magnification. The instruments were randomly assigned to a control group of new instruments preserved for surface roughness analysis (n = 6 each), or to an experimental group to shape the root canal system of a single molar (n = 20 each), making a total of four groups (WOGnew, EOnew, WOGused, EOused).

View Article and Find Full Text PDF

Background: This study aimed to assess the influence of continuous rotation and reciprocation kinematics on postoperative pain (POP) levels and substance P (SP) levels in patients diagnosed with irreversible pulpitis and symptomatic apical periodontitis (SAP).

Materials And Subjects: A total of twenty patients were randomly assigned into two groups: Continuous Rotation Group (CRG) (n = 10), subjected to mechanical preparation with the EdgeEndox7 rotary system (Albuquerque, NM, USA), and Reciprocation Group (RG) (n = 10), treated with the EdgeOne Fire reciprocating system (Albuquerque, NM, USA). Apical fluid (AF) samples were collected, and SP levels were quantified through radioimmunoassay.

View Article and Find Full Text PDF

Aim: To compare the design, metallurgy, and mechanical properties of four heat-treated reciprocating instruments coupled with the evaluation of the irrigation flow using an in silico model.

Methodology: New EdgeOne Fire Primary, Easy-File Flex Regular 25, WaveOne Gold Primary and Reciproc Blue R25 instruments (n = 124) were initially evaluated regarding their design through stereomicroscopy, scanning electron microscopy and 3D surface scanning. In addition, energy-dispersive X-ray spectroscopy was utilized to determine their elemental composition, and differential scanning calorimetry tests to evaluate their phase transformation temperatures.

View Article and Find Full Text PDF