Objectives: Low-density lipoprotein cholesterol (LDL-C) concentration was calculated for many years using the Friedewald equation, but those from Sampson and extended-Martin-Hopkins perform differently. Their accuracy in fasting hypertriglyceridemia and non-fasting state were compared and the clinical impact of implementing these equations on risk classification and on the setting of lipid treatment goals was assessed.
Methods: Seven thousand six standard lipid profiles and LDL-C concentrations measured after ultracentrifugation (uLDL-C) were retrospectively included. uLDL-C were compared to calculated LDL-C in terms of correlation, root mean square error, residual error, mean absolute deviations and cardiovascular stratification.
Results: In fasting state (n=5,826), Sampson equation was the most accurate, exhibited the highest percentage of residual error lower than 0.13 mmol/L (67 vs. 57 % and 63 % using Friedewald, or extended-Martin-Hopkins equations respectively) and the lowest misclassification rate. However, the superiority of this equation was less pronounced when triglyceride concentration (TG) <4.5 mmol/L were considered. In post-prandial state (n=1,180), extended-Martin-Hopkins was the most accurate equation, exhibited the highest percentage of residual error lower than 0.13 mmol/L (73 vs. 39 % and 57 % using Friedewald and Sampson equation respectively). Overall, the negative bias with Sampson equation may lead to undertreatment. Conversely, a positive bias was observed with extended Martin-Hopkins.
Conclusions: None of the equations tested are accurate when TG>4.52 mmol/L. When TG<4.52 mmol/L both Sampson and Martin-Hopkins equations performed better than Friedewald. The switch to one or the other should take in account their limitations, their ease of implementation into the lab software and the proportion of non-fasting patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1515/cclm-2023-0360 | DOI Listing |
Phys Med
September 2025
Department of Biomedical Technology, Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 8, 33720 Tampere, Finland; School of Electrical and Information Engineering, University of the Witwatersrand, Johannesburg, Jan Smutslaan 1, 2050 Braamfontein, South Africa.
Background And Objective: Correction of rotational setup errors by tilting the treatment couch improves target dose accuracy and prevents healthy tissue overdosage in external beam radiotherapy. However, couch tilts may cause secondary patient motion. This study aimed to quantify the secondary motion caused by pitch and roll corrections and to evaluate the feasibility of surface imaging for detecting the secondary motion in pelvic radiotherapy.
View Article and Find Full Text PDFJ Acoust Soc Am
September 2025
College of Geodesy and Geomatics, Shandong University of Science and Technology, Qingdao 266590, China.
The single-difference positioning method could eliminate the systematic error of long periods, which is one of the major factors affecting the seafloor geodetic acoustic positioning accuracy. Due to the poor observation geometry in short observation time, there is collinearity in the coefficient matrix. Therefore, a small observation error may lead to a large error in the least square solution, which is the ill-posed problem of single-difference positioning.
View Article and Find Full Text PDFJ Refract Surg
September 2025
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Purpose: To evaluate axis-dependent visual and refractive outcomes of small incision lenticule extraction (SMILE) in patients with interocular astigmatic axis discordance.
Methods: Seventy-five patients (150 eyes) with interocular astigmatic axis discordance were included in the study. Based on interocular axis combinations, patients were stratified into three cohorts: with-the-rule (WTR)/against-the-rule (ATR) (n = 19), WTR/oblique astigmatism (OA) (n = 39), and ATR/OA (n = 17).
J Refract Surg
September 2025
Purpose: To discuss the technique and outcome of what the authors called the "flap-in-flap" technique and report its safety as a procedure for correction of post-laser in situ keratomileusis (LASIK) myopic regression.
Methods: Seven eyes of 4 patients were included in this study. All patients had previously undergone LASIK for compound myopic astigmatism using the Moria M2 micro-keratome (Moria) 8 to 12 years prior to presentation.
Cureus
August 2025
Department of Ophthalmology, Kanazawa Medical University, Uchinada, JPN.
Intraocular repair for subluxation of a multifocal intraocular lens (MFIOL) can be challenging, especially in toric models. Herein, we report a case of a 43-year-old man with a subluxated toric-type single-piece trifocal intraocular lens (IOL) with a C-loop that was spared using suture repositioning. Pars plana suturing was performed using the haptic externalization technique, and the tram-track suture technique was employed to flatten the tilted toric MFIOL.
View Article and Find Full Text PDF