98%
921
2 minutes
20
This study examined the relation between both implementation fidelity and quality and the outcomes of two different anti-bullying interventions targeting distinct processes involved in bullying: moral disengagement and social norms. In total, 34 French-speaking Belgian teachers from six elementary schools were trained to deliver either the moral disengagement or the social norms intervention to their Grade 4-6 students (N = 747, 50.4% boys) in a randomized controlled trial. Students reported their moral disengagement, perceived injunctive class norm toward bullying, and bullying behaviors in the fall and spring of the 2018-2019 school year. Teachers' implementation fidelity and quality were assessed through direct observation in each class by two independent raters with a satisfying interrater reliability. A multiplicative moderated mediation model using latent change scores revealed that both greater fidelity and quality amplified students' decrease in moral disengagement, which was accompanied by a decrease in bullying. Importantly, when quality was sufficient, fidelity did not matter. However, higher fidelity could compensate for a lack of quality. Contrary to expectations, there was no significant change in students' perceptions of the class injunctive norm, even under ideal implementation conditions. Alternative mediators should thus be considered. Because implementation by teachers inevitably fluctuates, anti-bullying program components should be evaluated under various implementation conditions to determine their cost-effectiveness ratio and to gain insights into how anti-bullying programs work.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11093827 | PMC |
http://dx.doi.org/10.1007/s11121-023-01580-8 | DOI Listing |
Radiol Adv
September 2024
Department of Radiology, Northwestern University and Northwestern Medicine, Chicago, IL, 60611, United States.
Background: In clinical practice, digital subtraction angiography (DSA) often suffers from misregistration artifact resulting from voluntary, respiratory, and cardiac motion during acquisition. Most prior efforts to register the background DSA mask to subsequent postcontrast images rely on key point registration using iterative optimization, which has limited real-time application.
Purpose: Leveraging state-of-the-art, unsupervised deep learning, we aim to develop a fast, deformable registration model to substantially reduce DSA misregistration in craniocervical angiography without compromising spatial resolution or introducing new artifacts.
Glob Ment Health (Camb)
July 2025
Institute of Psychiatry, Psychology and Neuroscience, King's College London, London, UK.
Problem-solving therapy (PST) is a brief psychological intervention often implemented for depression. Currently, there are no tools with well-evidenced reliability to measure PST fidelity. This pilot study aimed to measure the inter-rater reliability and agreement of the blem-Slving Therapy idelity (PROOF) scale, comprising binary 14-item adherence and an 8-item competence subscales.
View Article and Find Full Text PDFMed Phys
September 2025
Department of Radiation Oncology, Mayo Clinic in Florida, Jacksonville, Florida, USA.
Background: Dose-driven continuous scanning (DDCS) enhances the efficiency and precision of proton pencil beam delivery by reducing beam pauses inherent in discrete spot scanning (DSS). However, current DDCS optimization studies using traveling salesman problem (TSP) formulations often rely on fixed beam intensity and computationally expensive interpolation for move spot generation, limiting efficiency and methodological robustness.
Purpose: This study introduces a Break Spot-Guided (BSG) method, combined with two acceleration strategies-dose rate skipping and bounding-to optimize beam intensity while minimizing beam delivery time (BDT).
J Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDFClin Rehabil
September 2025
Pritzker School of Medicine, University of Chicago, Chicago, IL, USA.
ObjectiveTo adapt and modify the successful SIESTA (Sleep for Inpatients: Empowering Staff to Act) sleep-promoting hospital protocol to an acute stroke rehabilitation setting.DesignThis study utilized a mixed methods design, involving qualitative surveys and interviews. Needs assessment and staff interviews informed the development of the adapted protocol, SIESTA-Rehab.
View Article and Find Full Text PDF