Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Total temporomandibular joint (TMJ) replacement is widely recognized as an effective treatment for TMJ disorders. The long-term stability of TMJ implants depends on two important factors which are design concepts for fixation to anatomical locations in the mandible and bone conditions. Other factors include stress distribution, microstrain in the peri-implant, bone attributes like bone conditions leading to the clinical complications and failures. This study addresses these limitations by examining the influence of patient-specific design concepts and bone conditions on TMJ implant performance. Clinical evidences support the importance of implant design on healing ability. Previous studies have focused on achieving precise implant fit based on geometric considerations, however those published studies did not explore the impact of such. Against this perspective, the present study reports the extensive finite element analysis (FEA) results, while analyzing the impact of a newly designed patient-specific TMJ implant to address clinical complications associated with various bone conditions, particularly osteoporotic bone. In validating the FEA results, the performance of additively manufactured patient-specific TMJ implants was compared with designs resembling two commonly used clinically approved implant designs. By addressing the limitations of previous research and emphasizing the importance of bone conditions, the study provides valuable guidelines for the development of next-generation TMJ implants. These findings contribute to enhanced clinical outcomes and long-term success in the treatment of TMJ disorders.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.35311DOI Listing

Publication Analysis

Top Keywords

bone conditions
20
tmj implants
12
temporomandibular joint
8
bone
8
tmj
8
treatment tmj
8
tmj disorders
8
design concepts
8
clinical complications
8
tmj implant
8

Similar Publications

Clinicopathological features of dermal clear cell sarcoma: A series of 13 cases.

Pathol Res Pract

September 2025

Department of Pathology, Xijing Hospital and School of Basic Medicine, Fourth Military Medical University, Xi'an, China. Electronic address:

Background: Dermal clear cell sarcoma (DCCS) is a rare malignant mesenchymal neoplasm. Owing to the overlaps in its morphological and immunophenotypic profiles with a broad spectrum of tumors exhibiting melanocytic differentiation, it is frequently misdiagnosed as other tumor entities in clinical practice. By systematically analyzing the clinicopathological characteristics, immunophenotypic features, and molecular biological properties of DCCS, this study intends to further enhance pathologists' understanding of this disease and provide a valuable reference for its accurate diagnosis.

View Article and Find Full Text PDF

Objective: Assessment of submarining occurrence in PMHS (Post-Mortem Human Subject) testing can be challenging, particularly for obese PMHS. This study investigates varied kinetic and kinematic response parameters as potential indicators of submarining. Data from 36 whole-body PMHS frontal sled tests conducted under varying boundary conditions were analyzed, incorporating three spring-controlled seat configurations, two extreme anthropometric profiles, two crash pulses, and two seatback angles.

View Article and Find Full Text PDF

In silico biophysics and rheology of blood and red blood cells in Gaucher Disease.

PLoS Comput Biol

September 2025

Division of Applied Mathematics, Brown University, Providence, Rhode Island, United States of America.

Gaucher Disease (GD) is a rare genetic disorder characterized by a deficiency in the enzyme glucocerebrosidase, leading to the accumulation of glucosylceramide in various cells, including red blood cells (RBCs). This accumulation results in altered biomechanical properties and rheological behavior of RBCs, which may play an important role in blood rheology and the development of bone infarcts, avascular necrosis (AVN) and other bone diseases associated with GD. In this study, dissipative particle dynamics (DPD) simulations are employed to investigate the biomechanics and rheology of blood and RBCs in GD under various flow conditions.

View Article and Find Full Text PDF

Crosstalk between leukemic cells and their surrounding mesenchymal stromal cells (MSCs) in the bone marrow microenvironment is crucial for the pathogenesis of myelodysplastic syndromes (MDS) and is mediated by extracellular vesicles (EVs). The EV-specific miRNAs derived from MDS-MSCs remain poorly explored. EVs isolated from HS-5, an immortalized stromal cell line, promoted the proliferation and 5-azacytidine (AZA) resistance of SKM-1 cells.

View Article and Find Full Text PDF

Background: Distal triceps tendon rupture is related to high complication rates with up to 25% failures. Elbow stiffness is another severe complication, as the traditional approach considers prolonged immobilization to ensure tendon healing. Recently, a dynamic tape was designed, implementing a silicone-infused core for braid shortening and preventing repair elongation during mobilization, thus maintaining constant tissue approximation.

View Article and Find Full Text PDF