98%
921
2 minutes
20
Cruor, the main component responsible for the red color of mammalian blood, contains 90% haemoglobin, a protein considered to be a rich source of bioactive peptides. The aim of the present study is to assess the potential of human hemoglobin as a source of bioactive peptides, compared with bovine hemoglobin, which has been extensively studied in recent years. More specifically, the study focused on the α137-141 fragment of bovine haemoglobin (TSKYR), a small (653 Da) hydrophilic antimicrobial peptide. In this work, the potential of human hemoglobin to contain bioactive peptides was first investigated in silico in comparison with bovine hemoglobin-derived peptides using bioinformatics tools. The blast results showed a high identity, 88% and 85% respectively, indicating a high similarity between the α and β chains. Peptide Cutter software was used to predict cleavage sites during peptide hydrolysis, revealing major conservation in the number and location of cleavage sites between the two species, while highlighting some differences. Some peptides were conserved, notably our target peptide (TSKYR), while others were specific to each species. Secondly, the two types of hemoglobin were subjected to similar enzymatic hydrolysis conditions (23 °C, pH 3.5), which showed that the hydrolysis of human hemoglobin followed the same reaction mechanism as the hydrolysis of bovine hemoglobin, the 'zipper' mechanism. Concerning the peptide of interest, α137-141, the RP-UPLC analyses showed that its identification was not affected by the increase in the initial substrate concentration. Its production was rapid, with more than 60% of the total α137-141 peptide production achieved in just 30 min of hydrolysis, reaching peak production at 3 h. Furthermore, increasing the substrate concentration from 1% to 10% (/) resulted in a proportional increase in α137-141 production, with a maximum concentration reaching 687.98 ± 75.77 mg·L, approximately ten-fold higher than that obtained with a 1% (/) concentration. Finally, the results of the UPLC-MS/MS analysis revealed the identification of 217 unique peptides in bovine hemoglobin hydrolysate and 189 unique peptides in human hemoglobin hydrolysate. Of these, 57 peptides were strictly common to both species. This revealed the presence of several bioactive peptides in both cattle and humans. Although some had been known previously, new bioactive peptides were discovered in human hemoglobin, such as four antibacterial peptides (α37-46 PTTKTYFPHF, α36-45 FPTTKTYFPH, α137-141 TSKYR, and α133-141 STVLTSKYR), three opioid peptides (α137-141 TSKYR,β31-40 LVVYPWTQRF,β32-40, VVYPWTQRF), an ACE inhibitor (β129-135 KVVAGVA), an anticancer agent (β33-39 VVYPWTQ), and an antioxidant (α137-141 TSKYR). To the best of our knowledge, these peptides have never been found in human hemoglobin before.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10418852 | PMC |
http://dx.doi.org/10.3390/ijms241511921 | DOI Listing |
Nutr Cancer
September 2025
Department of Kinesiology and Nutrition, University of Illinois Chicago, Iowa City, IL, USA.
Increased adiposity and chronic psychosocial stress (CPS) are plausible modifiable contributors of the recent increase in early-onset colorectal cancer (EOCRC). We conducted an 8-week randomized controlled pilot trial evaluating the feasibility and acceptability of time restricted eating (TRE) (daily ad libitum eating between 12-8pm) and Mindfulness ("Mindfulness for Beginners" course from the Calm app) among young adults. Participants were randomized to the following groups: TRE ( = 10); Mindfulness ( = 11); TRE & Mindfulness ( = 11); or Control ( = 11).
View Article and Find Full Text PDFAnn Hematol
September 2025
Abteilung für Hämatologie und Internistische Onkologie Klinik für Innere Medizin II, Universitätsklinikum Jena, Am Klinikum 1, 07747, Jena, Germany.
Background: Hemoglobin A1c (HbA1c) is a stable compound, which is an important indicator for diagnosing glycemia, evaluating blood glucose control in patients with diabetes, and guiding the formulation of treatment plans. However, the detection of HbA1c is easily affected by many factors, resulting in a false increase or decrease, which affects the accuracy of test results.
Methods: In this paper, two abnormal HbA1c results were detected in the laboratory, which did not match the blood glucose detected at the same time.
Medicine (Baltimore)
September 2025
Department of Nephrology, The Second Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu Province, China.
The purpose of this article was to study the distribution of left ventricular hypertrophy (LVH) and cardiac valve calcification (CVC), relevant factors, and the relationship of LVH and CVC with survival in maintenance hemodialysis (MHD) patients. A total of 281 MHD patients were included in this retrospective and follow-up study. Echocardiography measurements were performed to evaluate the left ventricular structure and cardiac valve.
View Article and Find Full Text PDFMedicine (Baltimore)
September 2025
Department of Nephrology and Blood Purification, Central Hospital Affiliated to Shandong First Medical University, Jinan, China.
Rationale: This case report aims to highlight a rare but life-threatening complication of femoral venous catheterization and to describe a novel endovascular technique for its management. Non-tunneled femoral catheters provide rapid vascular access for emergency dialysis (e.g.
View Article and Find Full Text PDF