Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A surface plasmon resonance (SPR) optical fiber sensor with multimode-coreless-multimode (MNM) structure was developed, which modified by L-glutamine-binding protein (QBP) for detection of L-glutamine (Gln). The QBP was immobilized on the surface of gold films by chemical cross-linking and exhibited a binding affinity for L-glutamine. The conformation of QBP can be changed from the "open" to the "closed", which led to a red-shift of the SPR peak when QBP bounded to L-glutamine. There was a good linear correlation between is a dependence of the SPR peak on and the concentration of L-glutamine concentration in the range 10-100 μM, with a sensitivity of 10.797nm/log[Gln] for L-glutamine in the in vitro embryo culture (IVC) medium environment, and the limit of detection (LOD) is 1.187 μM. This QBP-modified MNM structure optical fiber SPR sensor provides a new idea for the developmental potential assessment of embryos in the process of in vitro embryo culture.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2023.115537DOI Listing

Publication Analysis

Top Keywords

optical fiber
12
vitro embryo
12
embryo culture
12
surface plasmon
8
plasmon resonance
8
detection l-glutamine
8
mnm structure
8
spr peak
8
l-glutamine
7
l-glutamine binding
4

Similar Publications

Macular Optical Coherence Tomography Parameters and Incident Glaucoma Among Myopic Eyes.

Transl Vis Sci Technol

September 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, People's Republic of China.

Purpose: The purpose of this study was to estimate the correlations between macular optical coherence tomography (OCT)-derived metrics and incident glaucoma risk in myopic eyes.

Methods: This longitudinal observational study included 24,181 individuals with myopia (spherical equivalence [SE] ≤ -0.5 diopters [D]) from the UK Biobank study.

View Article and Find Full Text PDF

The development of sensors for monitoring breath acetone, a key biomarker for ketosis in diabetes mellitus, represents a critical frontier in medical diagnostics, promising a painless alternative to invasive blood tests. This review provides a comprehensive and critical evaluation of the state-of-the-art in acetone gas sensing technologies, including chemiresistive, optical, electrochemical, conductometric, and microwave platforms. We focus specifically on recent breakthroughs driven by advanced materials, analyzing how novel nanostructures from two-dimensional (2D) materials such as MXenes to porous metal-organic frameworks (MOFs) are engineered to push performance to clinically relevant parts-per-billion (ppb) sensitivity.

View Article and Find Full Text PDF

The persistent presence of Metronidazole (MTZ), a commonly used antibiotic, in water bodies is a serious environmental and health concern because of its genotoxic and carcinogenic potential. Here, we report an effective visible-light photocatalyst system comprising an S-scheme glycine-modified TiO/FeO heterojunction immobilized on chitosan-polyacrylonitrile nanofibers. The photocatalyst nanocomposite was synthesized through a sol-gel and ultrasonication process coupled with electrospinning-assisted immobilization.

View Article and Find Full Text PDF

Purpose: To assess the clinical outcomes of Hydrus Microstent implantation with cataract extraction for the treatment of open angle glaucoma (OAG) over a maximum of 4 years.

Design: Retrospective, single-center, single-arm, longitudinal cohort study.

Subjects: 308 patients (464 eyes) with OAG who underwent Hydrus Microstent implantation with cataract extraction between February 2019 and December 2021, followed for a median (interquartile range, IQR) of 2.

View Article and Find Full Text PDF

Quantitative assessment of retinal microvasculature using optical coherence tomography angiography and correlation with visual acuity in leber's hereditary optic neuropathy.

Int Ophthalmol

September 2025

Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing key Laboratory of Intraocular Tumor Diagnosis and Treatment, Beijing Ophthalmology and Visual Sciences Key Lab, Medical Artificial Intelligence Research and Verification Key Laboratory of the Ministry of Industry and Information Technolog

Purpose: To analyze macular microvascular networks and investigate correlations between visual acuity and quantitative parameters in patients with Leber's hereditary optic neuropathy (LHON) using optical coherence tomography angiography (OCTA).

Methods: An observational, cross-sectional study was conducted, including 25 eyes from 25 genetically confirmed chronic LHON patients and 25 eyes from 25 age-matched healthy controls. Images were obtained using a spectral domain OCTA system.

View Article and Find Full Text PDF