Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: The treatment of choice for aortic stenosis is a valve replacement. Some patients have post-procedural increased pressure gradient on the implanted prosthesis because of patient-prosthesis mismatch (PPM), known to adversely influence prognosis. The PPM risk should be initially predicted and effort made to avoid this complication, specifically in large body size patients.

Aim: To assess the frequency of PPM taking into account the valvular prosthesis type in a real-life population of consecutive patients included in the Krakow aortic stenosis registry.

Material And Methods: The KRAK-AS registry was conducted in July-October 2016. Patients were assessed before and after valve surgery and during the 3-year follow-up. Patients who underwent aortic valve intervention were clinically and echocardiographically evaluated within a month after surgery and divided into groups depending on the implanted prosthesis type. Analysis of patients with a smaller (< 23 mm) and larger than median (≥ 23 mm) valve diameter was performed.

Results: The valve implantation was performed in 229 patients (42 mechanical, 139 biological, 48 transcatheter). No differences between patient groups compared by PPM occurrence was seen at baseline. Median age was 70 years; 55.5% were men. At least moderate PPM (iEOA ≤ 0.85 cm/m) was observed in 40% of mechanical valves, 33% of biological valves, and was significantly less frequent (10%) in patients after transcatheter valve implantation, = 0.0001. Severe PPM (iEOA < 0.65 cm/m) was found in 17.6% of mechanical valve PPM patients, 4.3% of biological ones, and no patients after transcatheter procedure.

Conclusions: PPM is a frequent phenomenon in the real-life population of patients undergoing surgical aortic valve replacement, being significantly less frequent in the case of a transcatheter procedure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10351073PMC
http://dx.doi.org/10.5114/aic.2023.129214DOI Listing

Publication Analysis

Top Keywords

aortic valve
12
patients
10
valve
9
krak-as registry
8
aortic stenosis
8
valve replacement
8
implanted prosthesis
8
ppm
8
prosthesis type
8
real-life population
8

Similar Publications

Comparison of short- and long-term outcomes between transcatheter and surgical aortic valve replacement for bicuspid aortic valve stenosis: a systematic review and meta-analysis.

Int J Surg

September 2025

Department of Cardiovascular Surgery, The Affiliated Hospital, Southwest Medical University, Metabolic Vascular Diseases Key Laboratory of Sichuan Province, Key Laboratory of Cardiovascular Remodeling and Dysfunction, Luzhou, Sichuan, PR China.

Objective: This meta-analysis aimed to compare the perioperative safety and efficacy of transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR) in bicuspid aortic valve (BAV) stenosis.

Methods: We systematically analyzed studies from PubMed, Cochrane Library, Embase, and CNKI comparing TAVR and SAVR in BAV stenosis. Outcomes included postoperative mortality, complications, all-cause survival, and freedom from stroke.

View Article and Find Full Text PDF

Paraprosthetic Leakage and Infection Two Years after the Konno Procedure: A Case Report.

Kardiologiia

September 2025

West China Hospital of Sichuan University, Department of Cardiovascular Surgery, Sichuan University.

A middle-aged female presenting with progressive heart failure was admitted to the emergency department. She had a history of mitral and aortic valve replacement and a reoperation involving the Konno procedure. Echocardiography suggested a possible paraprosthetic leakage, which was confirmed during surgery.

View Article and Find Full Text PDF

Background: Mitral regurgitation (MR) may rarely worsen after transcatheter aortic valve implantation (TAVI) due to mechanical interference from the transcatheter heart valve (THV). Standard surgical approaches in these cases are often challenging due to anatomical constraints. Thus, there is a need for the development of effective alternatives to address this issue.

View Article and Find Full Text PDF

Rapid Atrial Pacing After TAVI for Pacemaker Prediction.

Rev Cardiovasc Med

August 2025

Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium.

Despite continued advancements in transcatheter aortic valve implantation (TAVI) techniques, the incidence of permanent pacemaker implantation (PPI) remains substantial. Established predictors of PPI include advanced age, pre-existing electrocardiographic conduction abnormalities, prosthetic valve type, implantation depth, and anatomical parameters, such as membranous septum length, which are currently under active investigation. In routine clinical practice, the management strategy often involves the temporary placement of a transvenous pacemaker lead, followed by a period of observation.

View Article and Find Full Text PDF

Background: Differences between female and male patients may influence the outcomes of transcatheter aortic valve replacement (TAVR). However, knowledge regarding known sex differences in TAVR procedures among Chinese people remains limited. Therefore, this study aimed to investigate the impact of sex-related differences on reverse left ventricular (LV) remodeling following TAVR in the Chinese population.

View Article and Find Full Text PDF