Effect of 3-Dimensional Imaging Device on Polyp and Adenoma Detection During Colonoscopy: A Randomized Controlled Trial.

Am J Gastroenterol

Department of Gastroenterology, Beijing Friendship Hospital, Capital Medical University, National Clinical Research Center for Digestive Disease, Beijing Digestive Disease Center, Beijing Key Laboratory for Precancerous Lesion of Digestive Disease, Beijing, China.

Published: October 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: To evaluate the effect of 3-dimensional (3D) imaging device on polyp and adenoma detection during colonoscopy.

Methods: In a single-blind, randomized controlled trial, participants aged 18-70 years who underwent diagnostic or screening colonoscopy were consecutively enrolled between August 2019 and May 2022. Each participant was randomized in a 1:1 ratio to undergo either 2-dimensional (2D-3D) colonoscopy or 3D-2D colonoscopy through computer-generated random numbers. Primary outcome included polyp detection rate (PDR) and adenoma detection rate (ADR), defined as the proportion of individuals with at least 1 polyp or adenoma detected during colonoscopy. The primary analysis was intention-to-treat.

Results: Of 1,196 participants recruited, 571 in 2D-3D group and 583 in 3D-2D group were finally included after excluding those who met the exclusion criteria. The PDR between 2D and 3D groups was separately 39.6% and 40.5% during phase 1 (odds ratio [OR] = 0.96, 95% confidence interval [CI]: 0.76-1.22, P = 0.801), whereas PDR was significantly higher in 3D group (27.7%) than that of 2D group (19.9%) during phase 2, with a 1.54-fold increase (1.17-2.02, P = 0.002). Similarly, the ADR during phase 1 between 2D (24.7%) and 3D (23.8%) groups was not significant (OR = 1.05, 0.80-1.37, P = 0.788), while ADR was significantly higher in 3D group (13.8%) than that of 2D group (9.9%) during phase 2, with a 1.45-fold increase (1.01-2.08, P = 0.041). Further subgroup analysis confirmed significantly higher PDR and ADR of 3D group during phase 2, particularly in midlevel and junior endoscopists.

Discussion: The 3D imaging device could improve overall PDR and ADR during colonoscopy, particularly in midlevel and junior endoscopists. Trial number: ChiCTR1900025000.

Download full-text PDF

Source
http://dx.doi.org/10.14309/ajg.0000000000002396DOI Listing

Publication Analysis

Top Keywords

imaging device
12
polyp adenoma
12
adenoma detection
12
3-dimensional imaging
8
device polyp
8
randomized controlled
8
controlled trial
8
detection rate
8
higher group
8
pdr adr
8

Similar Publications

Background: Cryolipolysis is an effective, well-tolerated noninvasive subcutaneous fat reduction treatment.

Objective: Assess participant satisfaction, effectiveness, and safety of a dual-applicator cryolipolysis system that can deliver simultaneous treatments.

Materials And Methods: Adult participants received treatment to the abdomen/flanks (midsection).

View Article and Find Full Text PDF

Advancements in digital media have driven the study and use of photographic records as a diagnostic method for carious lesions, with smartphone images being widely utilized across various health fields. This study aimed to evaluate the diagnostic accuracy of smartphone photography for detecting active caries in orthodontic patients. The sample comprised 100 individuals of both sexes, aged 11 to 46 years, who were undergoing fixed orthodontic treatment.

View Article and Find Full Text PDF

A compact cassette tape for DNA-based data storage.

Sci Adv

September 2025

Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering. Southern University of Science and Technology, No. 1088 Xueyuan Rd., Nanshan District, Shenzhen, Guangdong 518055, P. R. China.

DNA with high storage density can serve as an alternative storage medium to respond to the global explosion of data growth and become a powerful personal storage memory if an integrated compact device can store and handle large-scale data. Here, we incorporate a DNA cassette tape with 5.5 × 10 addressable data partitions (addressing rate up to 1570 partitions per second), a DNA loading capacity of 28.

View Article and Find Full Text PDF

Skin-adaptive focused flexible micromachined ultrasound transducers for wearable cardiovascular health monitoring.

Sci Adv

September 2025

State Key Laboratory for Manufacturing System Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme En

Continuous monitoring of cardiovascular vital signs can reduce the incidence and mortality of cardiovascular diseases, yet cannot be implemented by current technologies because of device bulkiness and rigidity. Here, we report self-adhesive and skin-conformal ultrasonic transducer arrays that enable wearable monitoring of multiple hemodynamic parameters without interfering with daily activities. A skin-adaptive focused ultrasound method with rational array design is proposed to implement measurement under wide ranges of skin curvatures and depths with improved sensing performances.

View Article and Find Full Text PDF

Achieving optimal alignment and fit is a key aspect of ankle-foot orthosis (AFO) design, as it directly influences the effectiveness of the device. While digital workflows offer the potential to integrate quantifiable alignment measures and corrections into AFO design, a major challenge remains in controlling lower-limb positioning and alignment during 3D scanning. This study aimed to evaluate pediatric AFO alignment and shape differences of directly scanned (live scan) vs casted lower limb models.

View Article and Find Full Text PDF