Enhancing Radiation Dose Efficiency in Prospective ECG-Triggered Coronary CT Angiography Using Calcium-Scoring CT.

Diagnostics (Basel)

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, 79085 Freiburg, Germany.

Published: June 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: This study investigates whether the scan length adjustment of prospectively ECG-triggered coronary CT angiography (CCTA) using calcium-scoring CT (CAS-CT) images can reduce overall radiation doses.

Methods: A retrospective analysis was conducted on 182 patients who underwent CAS-CT and prospectively ECG-triggered CCTA using a second-generation Dual-Source CT scanner. CCTA planning was based on CAS-CT images, for which simulated scout view planning was performed for comparison. Effective doses were compared between two scenarios: Scenario 1-CAS-CT-derived CCTA + CAS-CT and Scenario 2-scout-view-derived CCTA without CAS-CT. Dose differences were further analyzed with respect to scan mode and body mass index.

Results: Planning CCTA using CAS-CT led to a shorter scan length than planning via scout view (114.3 ± 9.7 mm vs. 133.7 ± 13.2 mm, < 0.001). The whole-examination effective dose was slightly lower for Scenario 1 (3.2 [1.8-5.3] mSv vs. 3.4 [1.5-5.9] mSv; < 0.001, = 182). Notably, Scenario 1 resulted in a significantly lower radiation dose for sequential scans and obese patients. Only high-pitch spiral CCTA showed dose reduction in Scenario 2.

Conclusions: Using CAS-CT for planning prospectively ECG-triggered CCTA reduced the overall radiation dose administered compared to scout view planning without CAS-CT, except for high-pitch spiral CCTA, where a slightly opposite effect was observed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10297591PMC
http://dx.doi.org/10.3390/diagnostics13122062DOI Listing

Publication Analysis

Top Keywords

radiation dose
12
prospectively ecg-triggered
12
scout view
12
ccta cas-ct
12
ccta
9
ecg-triggered coronary
8
coronary angiography
8
scan length
8
cas-ct
8
cas-ct images
8

Similar Publications

Gamma and X-ray radiation on mating and sperm transfer in sterile Anastrepha ludens (Diptera: Tephritidae).

J Econ Entomol

September 2025

Departamento de Ecología de Artrópodos y Manejo de Plagas, El Colegio de la Frontera Sur, Tapachula, Chiapas, Mexico.

Ionizing radiation is widely used in insect sterilization for pest control using the Sterile Insect Technique, which consists of the mass rearing of insects and their irradiation with gamma rays to release them in target areas where they will mate with wild females. However, there is a concern and controversy about the nuclear origin applied in this technique. One alternative for sterilization is the use of X-rays, which do not have a nuclear origin, are easier to operate, and do not generate radioactive waste.

View Article and Find Full Text PDF

Background: Among childhood cancer survivors, germline rare variants in autosomal dominant cancer susceptibility genes (AD CSGs) could increase subsequent neoplasm (SNs) risks, but risks for rarer SNs and by age at onset are not well understood.

Methods: We pooled the Childhood Cancer Survivor Study and St Jude Lifetime Cohort (median follow-up = 29.7 years, range 7.

View Article and Find Full Text PDF

Volumetric modulated arc therapy (VMAT) for lung cancer involves complex multileaf collimator (MLC) motion, which increases sensitivity to interplay effects with tumour motion. Current dynamic conformal arc methods address this issue but may limit the achievable dose distribution optimisation compared with standard VMAT. This study examined the clinical utility of a VMAT technique with monitor unit limits (VMATliMU) to mimic conformal arc delivery and reduce interplay effects while maintaining plan quality.

View Article and Find Full Text PDF

Unlabelled: Passive Acoustic Mapping (PAM) is rapidly emerging as a ubiquitous tool for real-time localization and monitoring of therapeutic ultrasound treatments involving cavitation in the context of safety or efficacy. The ability of PAM to spatially quantify and resolve cavitation activity offers a unique opportunity to correlate the energy of cavitation phenomena with locally observed bioeffects.

Objective: We aim to develop methods of measuring and reporting spatio-temporally varying cavitation energies that are energy-preserving, device-independent, and adequately normalized to the volume of tissue being affected by the reported cavitation activity.

View Article and Find Full Text PDF

Essentials of the System of Radiological Protection.

J Radiol Prot

September 2025

Centre for Radiation Protection Research, Stockholm University, Svante Arrheniusväg 20C, 106 91 Stockholm, Sweden.

The System of Radiological Protection (the "System") developed by the International Commission on Radiological Protection (ICRP) is built on nearly a century of efforts of numerous scientists and practitioners working together internationally. It rests on three enduring pillars: science, ethics, and experience. These pillars support the three fundamental principles that shape radiological protection strategies: justification, optimisation, and application of dose limits.