Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In breast tomosynthesis, multiple low-dose projections are acquired in a single scanning direction over a limited angular range to produce cross-sectional planes through the breast for three-dimensional imaging interpretation. We built a next-generation tomosynthesis system capable of multidirectional source motion with the intent to customize scanning motions around "suspicious findings". Customized acquisitions can improve the image quality in areas that require increased scrutiny, such as breast cancers, architectural distortions, and dense clusters. In this paper, virtual clinical trial techniques were used to analyze whether a finding or area at high risk of masking cancers can be detected in a single low-dose projection and thus be used for motion planning. This represents a step towards customizing the subsequent low-dose projection acquisitions autonomously, guided by the first low-dose projection; we call this technique "self-steering tomosynthesis." A U-Net was used to classify the low-dose projections into "risk classes" in simulated breasts with soft-tissue lesions; class probabilities were modified using post hoc Dirichlet calibration (DC). DC improved the multiclass segmentation (Dice = 0.43 vs. 0.28 before DC) and significantly reduced false positives (FPs) from the class of the highest risk of masking (sensitivity = 81.3% at 2 FPs per image vs. 76.0%). This simulation-based study demonstrated the feasibility of identifying suspicious areas using a single low-dose projection for self-steering tomosynthesis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10303463PMC
http://dx.doi.org/10.3390/tomography9030092DOI Listing

Publication Analysis

Top Keywords

low-dose projection
16
multiclass segmentation
8
simulation-based study
8
self-steering tomosynthesis
8
low-dose projections
8
risk masking
8
single low-dose
8
low-dose
6
breast
4
segmentation breast
4

Similar Publications

Background: Lung cancer (LC) is the leading cause of cancer death in Ireland, yet no national screening programme exists. While low-dose computed tomography (LDCT) screening reduces lung cancer mortality by approximately 20% in high-risk populations, its cost-effectiveness in Ireland remains uncertain. Evidence on the economic burden of lung cancer care and the feasibility of screening is needed to support policy decisions.

View Article and Find Full Text PDF

Background: Neoantigen-based vaccines show promising therapeutic potential in solid tumors such as melanoma, GBM, NSCLC, and CRC. However, clinical responses remain suboptimal in stage IV patients, due to ineffective T-cell function and high tumor burdens. To overcome these limitations, our study investigates a combination strategy using neoantigen peptide vaccines and precision critical lesion radiotherapy (CLERT), which delivers immunomodulatory doses to key tumor regions synergistically enhance immune activation and inhibit progression in multifocal stage IV patients.

View Article and Find Full Text PDF

Disentangled deep learning method for interior tomographic reconstruction of low-dose X-ray CT.

Phys Med Biol

September 2025

Engineering Physics, Tsinghua University, Liuqing Building, Haidian District, Beijing, China, Beijing, Beijing, 100084, CHINA.

Objective Low-dose interior tomography integrates low-dose CT (LDCT) with region-of-interest (ROI) imaging which finds wide application in radiation dose reduction and high-resolution imaging. However, the combined effects of noise and data truncation pose great challenges for accurate tomographic reconstruction. This study aims to develop a novel reconstruction framework that achieves high-quality ROI reconstruction and efficient extension of recoverable region to provide innovative solutions to address coupled ill-posed problems.

View Article and Find Full Text PDF

Energy drinks are rapidly gaining prominence in the global beverage industry, with projected sales reaching $60 billion within the next five years. These beverages often contain high levels of caffeine and the amino acid taurine, among other ingredients. The increasing consumption of energy drinks by children has sparked concerns regarding potential caffeine toxicity.

View Article and Find Full Text PDF

The management of adult spinal deformity (ASD) has evolved dramatically over the past century, transitioning from external bracing and in situ fusion to complex, technology-driven surgical interventions. This review traces the historical development of spinal deformity correction and highlights contemporary enabling technologies that are redefining the surgical landscape. Advances in stereoradiographic imaging now allow for precise, low-dose three-dimensional assessment of spinopelvic parameters and segmental bone density, facilitating individualized surgical planning.

View Article and Find Full Text PDF