Same-day repeatability and Between-Sequence reproducibility of Mean ADC in PI-RADS lesions.

Eur J Radiol

Division of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany; National Center for Tumor Diseases (NCT) Heidelberg, Heidelberg, Germany; German Cancer Consortium (DKTK), Germany; Heidelberg University Medical School, Heidelberg, Germany. Electronic address: d.bonekamp@dkfz-heidelb

Published: August 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: This study aimed to assess repeatability after repositioning (inter-scan), intra-rater, inter-rater and inter-sequence variability of mean apparent diffusion coefficient (ADC) measurements in MRI-detected prostate lesions.

Method: Forty-three patients with suspicion for prostate cancer were included and received a clinical prostate bi-/multiparametric MRI examination with repeat scans of the T2-weighted and two DWI-weighted sequences (ssEPI and rsEPI). Two raters (R1 and R2) performed single-slice, 2D regions of interest (2D-ROIs) and 3D-segmentation-ROIs (3D-ROIs). Mean bias, corresponding limits of agreement (LoA), mean absolute difference, within-subject coefficient of variation (CoV) and repeatability/reproducibility coefficient (RC/RDC) were calculated. Bradley & Blackwood test was used for variance comparison. Linear mixed models (LMM) were used to account for multiple lesions per patient.

Results: Inter-scan repeatability, intra-rater and inter-sequence reproducibility analysis of ADC showed no significant bias. 3D-ROIs demonstrated significantly less variability than 2D-ROIs (p < 0.01). Inter-rater comparison demonstrated small significant systematic bias of 57 × 10 mm/s for 3D-ROIs (p < 0.001). Intra-rater RC, with the lowest variation, was 145 and 189 × 10 mm/s for 3D- and 2D-ROIs, respectively. For 3D-ROIs of ssEPI, RCs and RDCs were 190-198 × 10 mm/s for inter-scan, inter-rater and inter-sequence variation. No significant differences were found for inter-scan, inter-rater and inter-sequence variability.

Conclusions: In a single-scanner setting, single-slice ADC measurements showed considerable variation, which may be lowered using 3D-ROIs. For 3D-ROIs, we propose a cut-off of ∼ 200 × 10 mm/s for differences introduced by repositioning, rater or sequence effects. The results suggest that follow-up measurements should be possible by different raters or sequences.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2023.110898DOI Listing

Publication Analysis

Top Keywords

same-day repeatability
4
repeatability between-sequence
4
between-sequence reproducibility
4
reproducibility adc
4
adc pi-rads
4
pi-rads lesions
4
lesions purpose
4
purpose study
4
study aimed
4
aimed assess
4

Similar Publications

Background: Baseball players and coaches may not have the personnel resources to monitor the pathological declines in shoulder function throughout the season. The ArmCare Strength and Range of Motion Sensor and Mobile Application (ArmCare testing system) was designed to allow players to test and monitor their shoulder range of motion (ROM) and strength.

Purpose: To establish the reliability and concurrent validity of the ArmCare testing system for measuring ROM and strength in high school and college baseball players.

View Article and Find Full Text PDF

The Inter-Tester and Test-Retest Reliability of the Off-Field SCAT6 Assessment Tool In An Adult Population.

J Head Trauma Rehabil

August 2025

Author Affiliations: School of Health and Social Care, Edinburgh Napier University, Edinburgh, UK (Mr McKeever, Drs Leavitt, and Valentin, Mr Hurley, and Mr Fraser); and Research Centre for Health, Glasgow Caledonian University, Glasgow, UK (Dr Hamilton).

Objective: No previously published repeatability and reliability data for The Sports Concussion Assessment Tool-6 (SCAT6) exists. We aimed to evaluate inter/intra-tester reliability of the off-field SCAT6 in a non-concussed adult population.

Design: Inter-rater and Intra-rater reliability study design.

View Article and Find Full Text PDF

Background: Among older adults, sex hormones may exert differential effects on body fat and cardiac health.

Objectives: The authors aimed to study the effects of sex on body fat composition and aging-related diastolic function, as well as their longitudinal changes.

Methods: Community-dwelling older adults without cardiovascular disease underwent prospective baseline same-day anthropometry for body fat mass (BFM), percentage body fat (PBF), and waist hip ratio (WHR) quantification by bioimpedance and transthoracic Doppler echocardiography, with measurements repeated at 5 years.

View Article and Find Full Text PDF

Sutton, PJ, Cintineo, HP, Mumford, PW, and Sunderland, KL. The relationship between external and internal load, sleep, and wellness during an off-season phase in women's collegiate NCAA Division I lacrosse athletes. J Strength Cond Res XX(X): 000-000, 2025-The purpose of this study was to investigate the bidirectional associations between workload, recovery, sleep, and wellness during the off-season in collegiate women's lacrosse athletes.

View Article and Find Full Text PDF

Objective: Early recurrence of epileptic seizures within the same day of emergency department (ED) admission poses clinical management challenges. While several blood-based parameters have been proposed as prognostic markers in various neurological disorders, their predictive utility in same-day seizure recurrence remains underexplored. We aimed to investigate whether inflammatory parameters derived from hemogram parameters can predict seizure recurrence within the same day in patients presenting with epileptic seizures or not.

View Article and Find Full Text PDF